Page 7 of 12 

 

 

 

 

 

 

 

 

 

 

 

Figure 4.1.2 RJ-45 connector straight through connecting 

 

 

PIN 

Workstation port 

MDI 

Input receive data+ 

Output transmit data+ 

Input receive data- 

Output transmit data- 

Output transmit data+ 

Input receive data+ 

Output transmit data- 

Input receive data- 

4, 5, 7, 8 

Nonuse 

Nonuse 

Table 4-1 RJ-45 Pin assignment 

 

Straight 

Cross 

(HA5400) 

(Adapter) 

(HA5400) 

(HUB/ HA5400) 

1 IRD+   

 

1 OTD+  1 IRD+ 

 

 

1 IRD+ 

2 IRD- 

 

 

2 OTD- 

2 IRD- 

 

 

2 IRD- 

3 OTD+   

 

3 IRD+ 

3 OTD+   

 

3 OTD+ 

6 OTD- 

 

 

6 IRD- 

6 OTD- 

 

 

6 OTD- 

Table 4-2 Straight and cross cable connecting 

 

iii.

 

Port Connection 

The MX-A5400 series can automatically detect the Ethernet cable type 
(Straight-through or Crossover), so either type may be used. An Ethernet 

Summary of Contents for MX-A5400 Series

Page 1: ...D Do op pe ed d F Fi ib be er r A Am mp pl li if fi ie er r M MX X A A5 54 40 00 0 S Se er ri ie es s U US SE ER R M MA AN NU UA AL L Sample Illustrations of MX 5400 Series Available in several confi...

Page 2: ...Optic connection 3 0 EDFA CONTROLS INDICATORS AND ALARMS 3 1 The operation of the panel 4 0 PORT AND CABLE ASSIGNMENTS 4 1 Management Port RJ 45 4 2 RS232 Console port DB9 4 3 Power Connection 5 0 FA...

Page 3: ...ls ITU wavelengths This series of EDFA offers a flexible and low cost solution for a CATV systems large coverage area The MX A5400 series EDFA s are a high performance multiple optical output EDFA s d...

Page 4: ...emperature Humidity should be not more than 95 under non coagulation condition It is recommended installing this unit in a dust free environment 3 The equipment can be powered by AC or steady voltage...

Page 5: ...the connector is clean and ready for connection If compressed air is not available the transmitter fiber bulkhead connector may be cleaned by a 2 5 mm alcohol sponge or the connector plate may be rem...

Page 6: ...ve different configurations and button displays MX A5400A 3 1Operation of the panel 3 1 1 Open menu A Plug in power supply B Turn on power switch located on the back panel for AC powered units Front p...

Page 7: ...ase temperature 10 IP Adjustable list displays the IP address 11 SUBMASK Adjustable list display the address of net mask 12 GATEWAY Adjustable list displays the gateway address 13 TRAP ADDR1 Adjustabl...

Page 8: ...The MX A5400 series management port connector type is RJ 45 Figure 4 1 1 RJ 45 Connector Plug and Socket The Management port RJ 45 can be connected to any device that uses a standard network interface...

Page 9: ...ansmit data Input receive data 4 5 7 8 Nonuse Nonuse Table 4 1 RJ 45 Pin assignment Straight Cross HA5400 Adapter HA5400 HUB HA5400 1 IRD 1 OTD 1 IRD 1 IRD 2 IRD 2 OTD 2 IRD 2 IRD 3 OTD 3 IRD 3 OTD 3...

Page 10: ...e only twisted pair cables with RJ 45 connectors that conform to FCC standards Note 1 Connect other compatible MX A5400 series or network hub adopt direct or across cable to connect MDI port in other...

Page 11: ...2 pin assignment Pin Distribution 2 RXD accepting of data 3 TXD transmitter data 5 SG signal Table 4 3 Pin information c Power Connection i Connection Description The power module provides stable oper...

Page 12: ...nd it only shows the relative parameter exceeding to normal scope slightly If the warning stops it indicates that the relative parameter has returned into the permitted scope The screen LBD will retur...

Page 13: ...ermitted range 6 Keep the optic fiber connector clean properly connected Prevent the output optic power from decreasing caused by optic leakage 18 GUARANTEE AND REPAIR ITEMS 1 Each unit is backed by M...