  Battery pack breakdowns 

 

If the following conditions occur, bring the Battery and Charger to your dealer. 

 

  If the red charging lamp does not flash when the charger plug is inserted into an AC 230V main power 

source outlet (When the battery pack is not inserted in the charger.) 

  If neither the red charging lamp nor the orange standby lamp lights or flashes when the battery pack is 

inserted in the charger. 

  If the orange standby lamp does not change to the red charging lamp even for more than 1 hour. 

  If the red charging lamp does not change from constant to flashing light even after more than 30 minutes 

have passed since starting charging. (Except during low temperature charging.) 

 
 
 

  Service Life of the Battery Pack   

If any condition described below is observed, the battery pack is at the end of its service life. Replace it with a 
new one.

 

 

  Although the battery pack has been properly charged (fully charged), a great drop in hours of use has been 

noticed. 

 
 
 

Don’t charge the battery pack when this happens. If the motor’s rotational speed slows down, the 
power of the battery pack is considered to be nearly depleted. Using the tool more will cause it to over 
discharge, resulting in a shortened service life of the battery pack and also in functional trouble of the 
tool’s main body. 
 
 
 
Don’t use a battery pack when its service life is finished. 
This will cause functional trouble in the tool’s main body. Also charging a battery pack that is out of 
service life will lead to functional trouble in the battery charger. 

 
 
 

  Recycling a NiCad Battery 

 

The MAX battery pack uses a NiCad battery, it may be illegal to dispose of this battery into the municipal 
waste system. Check with your local solid waste officials for details in your area for recycling options or proper 
disposal.

 

 
 
 
When disposing of the battery pack, make sure to put a pack cap on its terminal (with insulating tape 
securing it) to prevent short circuits. 
 
 
 

  Preventing the Battery Pack from Becoming Inactive   

When the tool is purchased, or when it is not used for extended periods (more than two months), the battery 
pack must be charged for 24 hours to reach top performance.

  13

Summary of Contents for RB215

Page 1: ...RB215 RE BAR TIER RE BAR TYING TOOL OPERATING and MAINTENANCE MANUAL BEFORE USING THIS TOOL STUDY THIS MANUAL TO ENSURE SAFETY WARNING AND INSTRUCTIONS KEEP THESE INSTRUCTIONS WITH THE TOOL FOR FUTUR...

Page 2: ...RNING Indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a potentially hazardous situation which if not avoided may result in mi...

Page 3: ...ATURES 10 4 BATTERY INSTRUCTIONS 11 5 OPERATING INSTRUCTIONS 14 6 MAINTENANCE 20 7 STORAGE 20 8 TROUBLESHOOTING REPAIRS OPERATING and MAINTENANCE MANUAL ENGLISH BEFORE USING THIS TOOL STUDY THIS MANUA...

Page 4: ...ETER 0 8 mm LENGTH 95 m coil RB515 3 wraps tie Approx 90 ties coil RB515 4 wraps tie Approx 75 ties coil RB395 Approx 120 ties coil TIES PER COIL RB215 Approx 180 210 ties coil TIES PER CHARGE Approx...

Page 5: ...his value is a tool related characteristic value and does not represent the influence to the hand arm system when using the tool An influence to the hand arm system when using the tool will for exampl...

Page 6: ...gh noise levels that could lead to hearing damage the employer and the user should make sure that necessary hearing protection is provided and used by the operator and others in the work area 3 DON T...

Page 7: ...RATE THE TOOL UNDER ANY ABNORMAL CONDITION If the tool is not in good working order or if any abnormal condition is noticed switch it off immediately set the Main switch at OFF lock the Trigger and ha...

Page 8: ...sonic Battery charger EY0230B and Battery Pack JP409 Failure to do so may cause the Battery to overheat or catch fire leading to serious injury Charge the Battery only to an AC 230V wall socket Failur...

Page 9: ...efully Don t carry the Battery charger by its power cord Don t use the power cord to disconnect it from a wall socket this will damage the cord and break the wires or cause a short circuit Don t let t...

Page 10: ...n be locked preventing the tool from operating for safety Always keep the Trigger locked when not in use Trigger Trigger lock Unless you are at tying work set the trigger lock to the position of LOCK...

Page 11: ...tery pack Red charging lamp Orange standby lamp When the orange standby light is lit When the Battery pack is hot after continuous use or exposure to direct sunlight the Charger will automatically swi...

Page 12: ...ower or batteries that have not been used for extended periods charging time must be extended longer When charging at low temperatures the red charging light will flash every 2 5 seconds Regarding tyi...

Page 13: ...e the battery pack when this happens If the motor s rotational speed slows down the power of the battery pack is considered to be nearly depleted Using the tool more will cause it to over discharge re...

Page 14: ...be sure only to use the specified MAX TW897 Do not use binding wire that has become rusted since the use of rusted wire will cause equipment breakdown Push the reel stopper to release the reel holder...

Page 15: ...stopper Feeding gears Release lever Tie Wire Remove the tape from the tie wire completely Remove slack from wire spool Make sure the Tie Wire does not get caught behind the wire spool This could lead...

Page 16: ...r Release Lever Wire guide Tie Wire Tie Wire Reel stopper Remove the Tie Wire Push the reel stopper to release the holder and remove the Tie Wire Mount the new Tie Wire Refer to the Tie Wire mounting...

Page 17: ...ase the tension turn it in the clockwise To decrease the tension turn it in the counterclockwise Insert the charged battery pack into the tool until a click is heard Main switch When setting the main...

Page 18: ...appropriate after binding use this dial to adjust it Mount the battery pack on the tool s main body insert the charged battery pack on to the main unit until a click is heard When setting the main sw...

Page 19: ...urface of crossed re bars During tool operation Do not move the tool during tying operation until the tool stops tying automatically Tie in alternate direction Cross tie Bent the tail of first tie bef...

Page 20: ...hildren All quality tools will eventually require servicing or replacement of parts because of wear from normal use REMOVE REEL OF TIE WIRE When you have finished the Tie Wire remove the Tie Wire from...

Page 21: ...21...

Page 22: ...ay be changed without notice as our policy is one of continuous improvement Temel Insaat Makina San ve Tic Ltd Sti Ankara Tel 312 342 5250 Telefaks 312 342 5282 www temelltd com tr www temelinsaat com...

Reviews: