Meter Specifications
Model
213
P002
214
215
216
1
Maximum flow rate
Gal/min:
0.48
0.53
2.64
9.25
26.4
Liters/min:
1.8
2.0
10
35
100
Maximum pressure (psi)
2xx-3xx, 2xx-4xx:
1,000 psi (70 bar)
2xx-6xx:
3,000 psi (210 bar)
P002, 214-5xx
7,250 psi (500 bar)
Pressure drop (PSIG)
Operating maximum:
15
15
28
30
30
Absolute maximum:
20
20
30
42
42
100% Flow (3cps):
3.25
3.25
3.5
5
9
2
Maximum temperature
--------------------- 1 part: 195°F (90°C) --------------------
2
Maximum temperature
-------------------- 2 part: 435°F (225°C) --------------------
3
Recommended filtration
10 micron
10 micron
10 micron
10 micron
10 micron
Displacement (cc/rev)
0.887
1.0
10.5
47.6
169.5
Weight (lbs)
1000 & 3000 psi
1.25 (0.57Kg)
---
6.25 (2.8Kg)
22.75 (10.3Kg)
55.25 (25.1Kg)
7250 psi
---
4.2 (1.9kg)
14.4 (6.5)
---
---
Typical k-factor (pulses/cc)
290 Frequency series
Transmitter
1000
1000
90
20
5
Port size (NPT):
0.125”
---
0.375”
0.500”
0.750”
SAE
#4 #4 #6 #12 #18
1
For viscosities of 30 cps or more, derate per pressure drop curves for higher viscosities.
2
Dependent on meter seal material, transmitter model, orientation and ambient temperature. See transmitter manual;
consult factory.
3
Some materials may have different filter requirements, consult factory.