4

3. Installation 

 

 

 

 

3.1 Connection to the mains 

For protection from electric shock, the fixture must be earthed! 

The LED COLOR ZOOM 300 is equipped with auto-switching power supply that automatically 

adjusts to any 50/60Hz AC power source from 100-240 Volts. 

Install a suitable plug on the power cord, note that the cores in the power cord are coloured 

according to the following table. The earth has to be connected! 

If you have any doubts about proper installation, consult a qualified electrician. 

Core (EU) 

Core (US) 

Connection   Plug

Terminal Marking 

Brown 

Light blue 

Yellow/Green 

Black               

White               

Green 

Live 

Neutral 

Earth 

 

 

 

3.2 Rigging the fixture 

The installation of the fixture has to be built and constructed in a way that it can hold 10 times 

the weight for 1 hour without any harming deformation. 

The installation must always be secured with a secondary safety attachment, e.g. an 

appropriate catch net. 

This secondary safety attachment must be constructed in a way that no part of the installation 

can fall down if the main attachment fails. 

When rigging, derigging or servicing the fixture staying in the area below the installation place, 

on bridges, under high working places and other endangered areas is forbidden. 

The operator has to make sure that safety-relating and machine-technical installations are 

approved by an expert before taking into operation for the first time and after changes before taking 
into operation another time. 

The operator has to make sure that safety-relating and machine-technical installations are 

approved by an expert after every four year in the course of an acceptance test. 

The operator has to make sure that safety-relating and machine-technical installations are 

approved by a skilled person once a year. 

CAUTION! 
Fixtures must be installed by a Qualified electrician in accordance with all 
national and local electrical and construction codes and regulatio

n.

 

Summary of Contents for ML-1319

Page 1: ...Zoom Moving Head 19LED 40w Model ML 1319...

Page 2: ...2 3 Installation 4 3 1 Connection to the mains 4 3 2 Rigging the fixture 4 4 CONTROL PANEL 6 5 Functions of the buttons Using the menu 7 6 MENU SETTING v1 0 8 7 DMX protocol v1 0 10 8 TECHNICAL INFOR...

Page 3: ...is can result in fire or electric shock Do not allow anything to rest on the power cord Do not locate this fixture where the cord may be damaged by persons walking on it Make sure that the power cord...

Page 4: ...tightly fastened Always use a secondary safety cable when mounting this fixture Make sure that the area below the installation place is blocked when rigging derigging or servicing the fixture Do not b...

Page 5: ...ary safety attachment e g an appropriate catch net This secondary safety attachment must be constructed in a way that no part of the installation can fall down if the main attachment fails When riggin...

Page 6: ...ce make sure there is no highly inflammable material decoration articles etc in a distance of min 0 5 m The fixture can be placed directly on the stage floor or rigged on a truss without altering its...

Page 7: ...to a XLR plug and plug it in the DMX output of the last fixture IMPORTANT The wires must not make contact with each other or with the metal casing of the connectors The casing itself must be connected...

Page 8: ...nu comfirms adjusted values and leaves menu Setting addresses and options with the projector disconnected The projector s DMX address as well as other possible operating options can also be set when t...

Page 9: ...tting Pan Reverse On Off Tilt Reverse On Off Pan Tilt Feedback On Off Pan Tilt mode Time Mode Speed Mode Pan Tilt Speed Standard Speed High Speed Colour Calibration On off Active Blackout While Blacko...

Page 10: ...eps Step1 Step99 Pan 0 255 Dimmer fine 0 255 Step Time 0 1 25 5s Save Save and copy Start Step 1 99 End Step 1 99 Playing Program Test Program In Loop Program 1In Loop Program 2In Loop Program 3In Loo...

Page 11: ...fast All zones together 224 255 Shutter open 2 2 2 0 255 Dimmer 8 bit Dimmer intensity from 0 to 100 3 3 3 0 255 Zoom Zoom from max to min beam angle 4 4 4 0 255 Pan 8 bit Pan movement by 540 5 5 5 0...

Page 12: ...p Blue full White 0 56 Light Blue Red 0 Green full Blue full White 0 57 95 Red 0 Green full Blue down White 0 96 Green Red 0 Green full Blue 0 White 0 97 134 Red up Green full Blue 0 White 0 135 Yello...

Page 13: ...trol 14 _ Beam Red Red fine zone 2 0 255 Red LEDs saturation control 0 100 0 255 Fine red LEDs saturation control 15 _ Beam Green Green fine zone 2 0 255 Green LEDs saturation control 0 100 0 255 Fine...

Page 14: ...en 0 Blue 0 176 214 Red full Green 0 Blue up 215 Magenta Red full Green 0 Blue full 216 246 Red down Green 0 Blue full 247 Blue Red 0 Green 0 Blue full 248 255 Reserved 21 18 _ Aura Red 0 255 Red LEDs...

Page 15: ...2 ENCAPSULATED STEPPING MOTOR ZOOM linear actuators Pan and tilt speed Adjustable via onboard control panel and DMX Pan Tilt movement Pan 540 Tilt 270 Control resolution 8 bit with 16 bit control of p...

Page 16: ...smoke fluid tends to building up residues reducing the light output very quickly The cooling fans should be cleaned monthly The interior of the base should be cleaned at least annually using a vacuum...

Reviews: