8
•
The overheating sensor detected an excessive high glass top temperature and caused it to
automatically shutdown. Heating empty cookware may cause this. Remove cookware and
let everything cool down and retry.
•
The air inlet or exhaust fan is blocked or failed and caused it to overheat. Make sure the
unit is at least 4” from walls and other objects and all vents are clear.
4.
The TEMPERATURE PROBE is not accurately keeping to the set temperature.
•
Verify the Temperature Function is selected (see Temperature Probe Section above).
•
Reattach the Probe to ensure it is securely connected.
SPECIFICATIONS
INDUCTION TYPE
Commercial rated/NSF approved
POWER SOURCE
220V/15A, 60Hz
WATTAGE RANGE
500 - 3000 watts (PL1-PL13)
TEMPERATURE RANGE
100ºF - 450ºF (15 settings)
WEIGHT
12.5 lbs. (5.7 kg)
DIMENSIONS
16.75” x 13.2” x 3.97” (425 x 336 x 100 mm)
CORD LENGTH
5 ft. (1.52m)
GLASS COOKTOP DIMENSIONS
11.25” x 11.25” (286 x 286 mm)
MAXIMUM WEIGHT LOAD
75 lbs. (cookware & contents)
TEMPERATURE PROBE
8” Probe. Stainless steel.
SAFETY FEATURES
Non-suitable cookware detection
Overheat protection
Improper voltage supply detection
APPROVALS
ETL US (conforms to UL STD 197)
ETL Sanitary approved (NSF4)
Complies with FCC Part 18
PRODUCT WARRANTY
(see warranty card included)
Aervoe Industries, Inc. warrants that this product shall be free from all defects in material and
workmanship for 1 year from date of purchase. All merchandise must be returned to the original place
of purchase to be processed according to the retailer return policy. A warranty card must be on file
with Aervoe Industries, Inc. within 30-days of purchase and proof of purchase is required to obtain
warranty performance.