Manual ME3011b_E_v0707_Pre.doc
8/50
5 - Event Register (Option)
5.1
Events
1000, with Time Stamp
5.2
Resolution
1 ms, samples 2,5 ms
5.3
Interfaces
RS232C or RS485
5.4
Protocols
Modbus RTU (Slave)
6 - Visualization
Light Indication
Back light
Available in red, yellow, green, white and blue colors
Ultra Bright Back light
Available in red, yellow, green, white and blue colors
Back Light Socket (Option)
Available in red, yellow, green, white and blue colors, on sockets
to allow color change at the field.
Led
5 mm visible red, yellow, and green color leds
6.1
Special Option
More than 1 color per annunciator
Fast: approx. 1.2 Hz
6.2
Flashing frequency
Slow: approx. 0.4 Hz
Windows
Dimension
24 x 48 mm
Back light
White translucent modules
6.3
Led
Gray RAL 7032 polycarbonate modules
7 – General
7.1
Alarm sequence
ISA 1, 1A, 1B, 2A, 2C, 4A, 4AR; others on request
Operation temperature: 0 to 55°C
Storage temperature: -20 to 80°C
7.2
Environment
Relative Humidity: 0 to 95 %, without condensation
Front: IP41
7.3
Protection class
Enclosure: IP30
7.4
Isolation
3000 V
eff
: IEC 60950-1
FAZER com Lote Piloto !!!
Immunity: DIN EN 61000-6-2
7.5
EMC Compliance
Emission: DIN EN 61000-6-4
7.6
ESD
DIN EN 61000-4-2
7.7
Electromagnetic Field Immunity DIN EN 61000-4-3
7.8
RF Frequency Immunity
DIN EN 61000-4-6
7.9
Burst
DIN EN 61000-4-4
7.10 Surge
DIN EN 61000-4-5
7.11 Voltage Dips
DIN EN 61000-4-11
7.12 Terminals
Terminal connectors (removable) for cables up to 2.5 mm²
7.13 Tropicalization
Special Option
TECHNICAL DATA