Manual ME3011b_E_v0707_Pre.doc
38/50
2
- Connection diagram with RRO and power fault indication, Vdc at alarm point 2 or yellow led on the keyboard end/or Vac fault at alarm point 4 or orange led on
the keyboard
Front view
Connector Identification
I1- X25-C1-1
R1 - X25-C2-1
I2 - X25-C1-2
R2 - X25-C2-2
I3 - X25-C1-3
R3 - X25-C2-3
I4- X25-C1-4
R4 - X25-C2-4
I1- X15-C1-1
R1 - X15-C2-1
I2 - X15-C1-2
R2 - X15-C2-2
I3 - X15-C1-3
R3 - X15-C2-3
I4- X15-C1-4
R4 - X15-C2-4
IN - X..-C_-N
I5 - X25-C1-5
R5 - X25-C2-5
I6 - X25-C1-6
R6 - X25-C2-6
I7 - X25-C1-7
R7 - X25-C2-7
I8 - X25-C1-8
R8 - X25-C2-8
I5 - X15-C1-5
R5 - X15-C2-5
I6 - X15-C1-6
R6 - X15-C2-6
I7 - X15-C1-7
R7 - X15-C2-7
I8 - X15-C1-8
R8 - X15-C2-8
I - Alarm Input
I1- X24-C1-1
R1 - X24-C2-1
I2 - X24-C1-2
R2 - X24-C2-2
I3 - X24-C1-3
R3 - X24-C2-3
I4- X24-C1-4
R4 - X24-C2-4
I1- X14-C1-1
R1 - X14-C2-1
I2 - X14-C1-2
R2 - X14-C2-2
I3 - X14-C1-3
R3 - X14-C2-3
I4- X14-C1-4
R4 - X14-C2-4
R - Alarm repeater relay (RRO)
I5 - X24-C1-5
R5 - X24-C2-5
I6 - X24-C1-6
R6 - X24-C2-6
I7 - X24-C1-7
R7 - X24-C2-7
I8 - X24-C1-8
R8 - X24-C2-8
I5 - X14-C1-5
R5 - X14-C2-5
I6 - X14-C1-6
R6 - X14-C2-6
I7 - X14-C1-7
R7 - X14-C2-7
I8 - X14-C1-8
R8 - X14-C2-8
X.. - Connector line
I1- X23-C1-1
R1 - X23-C2-1
I2 - X23-C1-2
R2 - X23-C2-2
I3 - X23-C1-3
R3 - X23-C2-3
I4- X23-C1-4
R4 - X23-C2-4
I1- X13-C1-1
R1 - X13-C2-1
I2 - X13-C1-2
R2 - X13-C2-2
I3 - X13-C1-3
R3 - X13-C2-3
I4- X13-C1-4
R4 - X13-C2-4
C - Connector
I5 - X23-C1-5
R5 - X23-C2-5
I6 - X23-C1-6
R6 - X23-C2-6
I7 - X23-C1-7
R7 - X23-C2-7
I8 - X23-C1-8
R8 - X23-C2-8
I5 - X13-C1-5
R5 - X13-C2-5
I6 - X13-C1-6
R6 - X13-C2-6
I7 - X13-C1-7
R7 - X13-C2-7
I8 - X13-C1-8
R8 - X13-C2-8
N - Connector terminal
cooresponding to the Alarm Point
I1- X22-C1-1
R1 - X22-C2-1
I2 - X22-C1-2
R2 - X22-C2-2
I3 - X22-C1-3
R3 - X22-C2-3
I4- X22-C1-4
R4 - X22-C2-4
I1- X12-C1-1
R1 - X12-C2-1
I2 - X12-C1-2
R2 - X12-C2-2
I3 - X12-C1-3
R3 - X12-C2-3
I4- X12-C1-4
R4 - X12-C2-4
I5 - X22-C1-5
R5 - X22-C2-5
I6 - X22-C1-6
R6 - X22-C2-6
I7 - X22-C1-7
R7 - X22-C2-7
I8 - X22-C1-8
R8 - X22-C2-8
I5 - X12-C1-5
R5 - X12-C2-5
I6 - X12-C1-6
R6 - X12-C2-6
I7 - X12-C1-7
R7 - X12-C2-7
I8 - X12-C1-8
R8 - X12-C2-8
I1- X21-C1-1
R1 - X21-C2-1
I2 - X21-C1-2
R2 - X21-C2-2
I3 - X21-C1-3
R3 - X21-C2-3
I4- X21-C1-4
R4 - X21-C2-4
I1- X11-C1-1
R1 - X11-C2-1
I2 - X11-C1-2
R2 - X11-C2-1
Vdc Fault (*)
RD - X11-C3-2(*)
I5 - X21-C1-5
R5 - X21-C2-5
I6 - X21-C1-6
R6 - X21-C2-6
I7 - X21-C1-7
R7 - X21-C2-7
I8 - X21-C1-8
R8 - X21-C2-8
I3 - X11-C1-3
R3 - X11-C2-3
I4 - X11-C1-4
R4 - X11-C2-4
Vac Fault (*)
RA - X11-C3-1(*)
(*)If the Alarm points 2 an 4 are
used for Power Suply Fault
detector, the correspondent
repeaters are on connector C3
repeaters
Vdc Fault
Vac Fault
CONNECTION DIAGRAM EXAMPLES