5 Matsusada Precision Original Command
s
10
KAS/KAS-R series, -LRs/-LRs4 option
POL command
Set P or N of the polarity.
Range
P/N
Format ex.
POL P
POL N
Initial value
POL P
Query
In response to
“POL?”, it returns “POL=P” or “POL=N”.
Remarks
・
This supports "Multi-command".
・
This command is available only for KAS-R series.
VGET command
Monitor the output voltage voltage value.
Range
0 to the rated voltage value
Resolution
Refer to [5-7
Resolution of Command Setting and Return Values].
Unit
kV
Format
VGET
Response ex.
VGET=12.34
⇒
12.34kV is output.
IGET command
Monitor the output current value.
Range
0 to the rated current value
Resolution
Refer to [5-7
Resolution of Command Setting and Return Values].
Unit
mA
Format
IGET
Response ex.
IGET=12.34
⇒
12.34mA is output.
STS command
The unit status is returned.
Format ex.
STS
Response
#(unit number) (status)
Response ex.
#1 CO LO
⇒
Unit 1 is in a state of output enabled and local mode.
#1 CF RM
⇒
Unit 1 is in a state of output disabled and remote mode.
Status
Output state
Control mode
CF
Output-cutoff
LO
Local mode
CO
Output enabled
RM
Remote mode
Remarks
・
Either one of them, CF or CO, LO or RM will surely be output.
・
In the error status, all errors that occurred will be returned.
・
A space (20H) will be inserted to separate each state.
・
In local mode, the output-cutoff will be returned.