SPECIFICATIONS

Part Number

MA98411

Application Voltage

12 Volt DC and 24 Volt DC

Operating Voltage

Sensing: 9V DC Minimum, 38V DC Maximum 

Switching: 33V DC Maximum

Continuous Contact 

Rating

150 Amps Maximum (rated at 40

o

C)

Momentary Contact 

Rating

500 Amps DC for a period of 10 seconds at 

10% duty cycle (rated at 40

o

C)

Contact State

User selectable normally open or closed

Environmental 

protection

To IP66

Electrical Protection

Thermal overload shutdown

Standby Current Draw

10mA at 13.5V DC and 23mA at 27.0V DC

Standby Current Draw

35mA at 13.5V DC and 55mA at 27.0V DC

Operating Temperature 

Ideally -25

o

C to +50

o

C

Alarm Output Signal

Equal to input voltage to 200mA maximum

Operating Humidity

Ideally should not exceed 95%

Enclosure Housing

E-coated A360 (ADC 3) die cast aluminium 

Enclosure Cover and 

Terminal Protector

Injection moulded electrical grade ABS/PC

Load Terminals

Tin plated copper stud

Control Terminals

Tin plated brass contact

Dimensions

135mm L x 85mm W x 65mm H

Weight

0.55kg

Summary of Contents for MA98411

Page 1: ...Matson Programmable Voltage Sensitive Relay MA98411...

Page 2: ...ions are also able to be time delayed to prevent VSR chatter as well as being able to program an alarm activation at a user defined voltage level The MPVSR is truly the next generation of charging con...

Page 3: ...ts of the MPVSR before installing or using Please take into account the environmental limitations of the product The device is water and dust resistant but is not designed to be installed in wet or ex...

Page 4: ...LAYOUT...

Page 5: ...ble for your application If the cable gauge is too small you will suffer voltage drop reduced current over heating of cabling and general poor performance even failure If you have any doubts consult t...

Page 6: ...Poor connections can result in overheating damaging the MPVSR For advice on termination please contact the place of purchase an auto electrician or The Matson Group See below for termination examples...

Page 7: ...ttings It is worth keeping in mind that you may not need to alter the factory settings which are listed in the table below 12 Volt DC Upper Voltage Limit 13 7 Volts Upper Time Delay 5 Seconds Lower Vo...

Page 8: ...o programming by bumping the buttons Press the SET button once the screen will show OFF Press the SET button a second time The screen will show the current setting relating to whichever LED is illumin...

Page 9: ...e the UP and DOWN buttons to cycle through to the next setting you would like to change and repeat the process Once you have set all the values to your requirements take your hands off the unit After...

Page 10: ...ut voltages of the MPVSR specific to the vehicle makes this product perfect for modern vehicles with VARIABLE VOLTAGE OUTPUT ALTERNATORS Setting Guide note this setup requires the MPVSR bet programmed...

Page 11: ...uts out and isolates the primary starting battery A delay is useful here because the voltage of the starting battery may drop below this point for a few seconds when starting the vehicle but return to...

Page 12: ...s been charged back to a safe voltage to start the vehicle It can be as little as 0 1V above the LOWER LIMIT IN VOLTS LOWER LIMIT IN VOLTS This is the voltage level where you want to disconnect the lo...

Page 13: ...LOW VOLTAGE DISCONNECT WIRING EXAMPLE 12 Volt Primary Battery Sensing BUZZER LOAD 150A MAX MUTE SWITCH OPTIONAL REMOTE OVERRIDE SWITCH SENSE WIRE...

Page 14: ...the batteries are in parallel Setting Guide note this setup requires the MPVSR bet programmed normally closed UPPER LIMIT IN VOLTS This is the setting where the batteries will be disconnected from eac...

Page 15: ...AUTOMATIC PARALLELING WIRING EXAMPLE SENSE WIRE 12 Volt Primary Battery Sensing 12 Volt Secondary Battery Charging BUZZER MUTE SWITCH OPTIONAL...

Page 16: ...this setup requires the MPVSR bet programmed normally open UPPER LIMIT IN VOLTS This is the setting where the voltage would be re connected to the light to allow it to operate as required again In thi...

Page 17: ...AUTOMATIC LOAD SWITCHING WIRING EXAMPLE LOAD 150A MAX FLOAT SWITCH...

Page 18: ...DC The control device is wired in series with the control wires and activated as required The voltage settings should be programmed out of any range that would affect operation Also the relay can be s...

Page 19: ...o IP66 Electrical Protection Thermal overload shutdown Standby Current Draw 10mA at 13 5V DC and 23mA at 27 0V DC Standby Current Draw 35mA at 13 5V DC and 55mA at 27 0V DC Operating Temperature Ideal...

Page 20: ...DIMENSIONS H 65mm L 135mm W 85mm...

Page 21: ...y phoning Matson on the above number provide satisfactory proof of purchase and send the faulty item to the address supplied above Exclusions from Warranty This warranty does not apply to products whe...

Page 22: ...third party or any special indirect or consequential loss or damage of any nature whatsoever caused by Matson s failure in complying with its obligations MATSON IS NOT RESPONSIBLE FOR DAMAGE THAT OCCU...

Page 23: ...ased From Date Purchased Product Purchased Model No This product is supplied with a 5 Year Warranty from date of purchase Please Note Should you experience any warranty related issues with this charge...

Page 24: ......