74
9.18 HearT raTe board rePlaCemeNT
CHaPTer 9: ParT rePlaCemeNT GUide
1) Turn off the power and disconnect the cord from the machine.
2) Remove the console as outlined in Section 9.13.
3) The heart rate board is located in front of the red Emergency Stop button (Figure A).
4) Disconnect wires from each side of the heart rate board (Figure B).
5) Use a Phillips screwdriver to remove two screws, one from each side of the heart rate board mounting bracket (Figure C).
6) Be sure to fully seat the wires on the new heart rate board and test the grips after the console is reinstalled.
fiGUre a
fiGUre b
fiGUre C
Summary of Contents for T7X-01
Page 1: ...T 7 x 0 1 T r e a d m i l l S ER V I C E MA N U A l...
Page 2: ......
Page 5: ...1 1 1 Serial Number Location Chapter 1 Serial number location...
Page 36: ...32 Chapter 8 TROUBLESHOOTING 8 1 Electrical Diagram...
Page 37: ...33 P29 Digital Communication Wire 8 1 Electrical Diagram Chapter 8 Troubleshooting...
Page 39: ...35 8 2 MCB LED Instructions Chapter 8 Troubleshooting...
Page 95: ...91 NOTEs...