39
8.5 error meSSaGe TroUbleSHooTiNG
error meSSaGeS - 0x01a2, 0x01a0, 0x0140, and 0x01a1.
1) CAUSE - Incline direction is reversed.
2) SOLUTION:
a. Check that the incline motor cable is connected at the MCB.
b. Press ENTER, 2, 0, 0, 1, ENTER on the console. The display should now read Engineering Mode.
c. Press the button next to Auto Calibration to begin the calibration procedure. If the unit passes auto calibration, delete the error log, the
unit is operational.
d. IF AUTO CALIBRATION FAILS, press the button next to GO TO VALUE across from INCLINE MIN on the display (Figure A).
e. Check to see if the LED UP and DOWN lights are lit on the MCB as you change the Incline Minimum. If LEDs are not lit, check the
console cable and console. If LEDs are lit, replace the incline motor (Figure B).
f. If the incline motor does not resolve the issues, replace the MCB.