45
9.14 gENERAToR REPlACEMENT
1) Remove the shrouds as outlined in Section 9.11.
2) Remove the 6 screws holding the generator to the frame (Figure A).
3) Remove the nut from the tension eye bolt (Figure B).
4) Once the nut from the tension eye bolt has been removed, the generator belt can be walked off the generator pulley (Figure C).
5) Disconnect the generator wire harness (Figure D), and remove the generator.
6) Reverse Steps 1-5 to install a new generator.
note:
Be sure to re-tension the generator belt to 85 lbs. .
7) Test the stepper for function as outlined in Section 9.22.
fIgURE A
fIgURE b
fIgURE C
fIgURE D
CHAPTER 9: PART REPlACEMENT gUIDE
Summary of Contents for S5X-04
Page 1: ...S 5 x 0 4 S T E P P E R S E R V I C E M A N U A l...
Page 17: ...14 8 1 electrical diagrams Chapter 8 Troubleshooting HURES5x C Electrical block diagram...
Page 18: ...15 8 1 Electrical Diagram CONTINUED Chapter 8 Troubleshooting s5x F Electrical block diagram...
Page 19: ...16 8 1 electrical diagramS CONTINUED Pulse Sensor Wire Chapter 8 Troubleshooting...
Page 23: ...20 8 4 LCB wiring connectionS CHAPTER 8 Troubleshooting...
Page 72: ...69 NOTES...