6
DEDICATED CIRCUIT AND ELECTRICAL INFO
A “Dedicated Circuit” means that each outlet you plug into should not have anything else
running on that same circuit. The easiest way to verify this is to locate the main circuit breaker
box, and turn off the breaker(s) one at a time. Once a breaker has been turned off, the only
thing that should not have power to it are the units in question. No lamps, vending machines,
fans, sound systems, or any other item should lose power when you perform this test.
Non-looped (isolated) neutral/grounding means that each circuit must have an individual
neutral/ground connection coming from it, and terminating at an approved earth ground.
You cannot “jumper” a single neutral/ground from one circuit to the next.
ELECTRICAL REQUIREMENTS
For your safety and to ensure good unit performance, the ground on this circuit must
be non-looped (isolated). Please refer to NEC article 210-21 and 210-23. Any alterations
to the standard power cord provided could void all warranties of this product.
The 1x cycles are designed to be self-powered and do not require an external power supply source to
operate. Without an external power supply, the console’s start-up time may be delayed. Add-on TV’s and
other console accessories will increase the time needed for start-up. An external power supply will ensure
power is provided to the console at all times and is recommended when add-on accessories are used.
For units with an integrated TV (1xe), the TV power requirements are included in the unit. An RG6
quad shield coaxial cable with ‘F Type’ compression fittings on each end will need to be connected
to the cardio unit and the video source. Additional power requirements are not needed for the
add-on digital TV. For units with an add-on PCTV, the TV power requirements are separate.
NOTE: All units with Virtual Active
™
must be powered.
110 V UNITS
All Matrix 1x 110 V cycles require the use of a 100-125 V, 60 Hz and a 15 A “Dedicated
Circuit”, with a non-looped (isolated) neutral/ground for power. This outlet should
be a NEMA 5-15R and have the same configuration as the plug. No adapter should
be used with this product. These cycles can be daisy-chained together with up to 4
units per 15 A dedicated circuit. Matrix daisy-chain cord adapters are sold separately.
220 V UNITS
All Matrix 1x 220 V cycles require the use of a 216-250 V, 50 Hz and a 15 A “Dedicated
Circuit”, with a non-looped (isolated) neutral/ground for power. This outlet should
be a NEMA 6-15R and have the same configuration as the plug. No adapter should
be used with this product. These cycles can be daisy-chained together with up to 4
units per 15 A dedicated circuit. Matrix daisy-chain cord adapters are sold separately.
GROUNDING INSTRUCTIONS
The unit must be grounded. If it should malfunction or breakdown, grounding
provides a path of least resistance for electric current to reduce the risk
of electric shock. The unit is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must be plugged into
an appropriate outlet that is properly installed and grounded in accordance
with all local codes and ordinances. If the user does not follow these
grounding instructions, the user could void the Matrix limited warranty.
ADDITIONAL ELECTRICAL INFO
In addition to the dedicated circuit requirement, the proper gauge wire
must be used from the circuit breaker box, to each outlet that will have
the maximum number of units running off of it. If the distance from the
circuit breaker box to each outlet, is 100 ft (30.5 m) or less, then 12 gauge
wire should be used. For distances greater than 100 ft (30.5 m) from the
circuit breaker box to the outlet, a 10 gauge wire should be used.
ENERGY SAVING / LOW-POWER MODE
All units are configured with the ability to enter into an energy saving / low-
power mode when the unit has not been in use for a specified period of
time. Additional time may be required to fully reactivate this unit once it has
entered the low-power mode. This energy saving feature may be enabled
or disabled from within the ‘Manager Mode’ or ‘Engineering Mode.’
ADD-ON PCTV
A 15 A or 20 A “Dedicated Circuit” with a non-looped (isolated) neutral/
ground is required. Each PCTV requires at least 1.2 A of current. No more
than 12 PCTVs should be used for each 15 A circuit and no more than 16
PCTVs should be used for each 20 A circuit. The power outlet should have
the same configuration as the plug. No adapter should be used with this
product. An RG6 coaxial cable with ‘F Type’ compression fittings will need
to be connected between the video source and each add-on PCTV unit.
ADD-ON DIGITAL TV
Additional power requirements are not needed for the add-on digital TV.
An RG6 coaxial cable with ‘F Type’ compression fittings will need to be
connected between the video source and each add-on digital TV unit.
North American
power cord plugs
shown. Depending
on your country, the
plug type may vary.
110 NEMA 5-15P
PLUG
220 NEMA 6-15P
PLUG
POWER REQUIREMENTS
ENGLISH
Summary of Contents for R1x
Page 1: ...U1x U1xe R1x R1xe...
Page 17: ...17 U1x M 6 U1X ASSEMBLY COMPLETE Pre installed Hardware Description Qty M Bolt 4 ENGLISH...
Page 97: ...97 M 6 U1x MONTAJE DE U1X FINALIZADO Piezas preinstaladas Descripci n Cant M Perno 4 ESPA OL...
Page 117: ...117 80 RPM 14 3 14 14...
Page 119: ...119 R1x 120 U1x 125...
Page 120: ...120 R1x...
Page 122: ...122 R1x 2 3 D C E F G C D 2 2 E F G 4 4 4...
Page 123: ...123 R1x 4 5 H I J K H I 2 4 J K 4 4...
Page 124: ...124 6 7 O N M L Q P R1x R1X L M N O 4 4 4 3 P Q 2 5...
Page 125: ...125 U1x...
Page 127: ...127 2 C D U1x 3 E F H G G I C D 2 2 E F G H I 4 4 6 2 2...
Page 128: ...128 4 J K L U1x J 4 5 K L 3 3...
Page 129: ...129 M 6 U1x U1X M 4...
Page 130: ...130 UV 600 mm 24 in 6 mm pin 1 23 23 0 6 m 2 ft 0 6 m 2 ft 0 6 m 2 ft...
Page 131: ...131 5 15 20...
Page 165: ......
Page 166: ......
Page 167: ......
Page 168: ...R1x U1x Cycle Frame 2016 Johnson Health Tech Part 1000390126 Rev 1 0 B...