CHAPTER 2: Troubleshooting
2.4 Heart Rate/Quick Keypad Issue
Symptom:
Heart Rate Function Does Not Work or is Reading Incorrectly
Quick
K
ey Function Does Not Work or Work
s
Incorrectly
Solution:
A. Heart Rate:
1.The heart rate grips are not connected properly or are defective.
With a multi-meter set for DC voltage, place one terminal on each of the HR grip plates.(Fig1) The
HR grip should give a voltage reading of between 0.5 and 2.0VDC. If the voltage is not between 0.5
and 2.0VDC, remove the 3 screws holding the HR grip together and check the connection of the HR
grip wiring.
2.The heart rate grip wiring is damaged or not connected correctly.
Check continuity of the HR grip wiring.
Place one terminal of a multi-meter set for resistance on the HR grip wiring at the HR grip, and the
other terminal on the HR grip wiring at the console. An ohm reading of around 1 should be expected.
If the reading is higher than 1, replace the HR grip wiring.
3. The HR board is damaged
Remove the console. Remove the 6 screws holding the front of the console to the rear. Check the
connection of the HR board wiring to the UCB. If all the wiring is intact and has good contact, replace
the HR board.
4.The UCB is damaged.
If the HR board, HR grips, and HR grip wiring do not solve the issue, replace the UCB.
B. QUICK Key ISSUE
The keypad connection wire
s
are not connected properly or are defective.
With a multi-meter set for ohms, place one terminal on quick key slot red wire (Fig2) .the others termi-
nal place one connection slot (fig3). It should read 0 ohms. If not . It mean wire damage. Replace
new console wire.