background image

7

WARRANTY

For North America, please visit 

www.matrixfitness.com for warranty 

information along with warranty exclusions and limitations.

PRODUCT SPECIFICATIONS

Max User Weight

159 kg / 350 lbs.

Max Training Weight

 94.6 kg / 208 lbs.

Product Weight

219 kg / 483 lbs.

Weight Stack

 91 kg / 200 lbs.

Add-On-Weight (optional)

0.9 kg / 2 lbs.

Overall Dimensions

(L x W x H)*

160 x 126 x 167 cm /

63” x 50” x 66”

* Ensure a minimum clearance width of 0.6 meters (24”) for access to and pas-

sage around MATRIX strength equipment. Please note, 0.91 meters (36”) is the 

ADA recommended clearance width for individuals in wheelchairs.

MAINTENANCE CHECKLIST

ACTION

FREQUENCY

Clean Upholstery 

1

Daily

Inspect Cables 

2

Daily

Clean Guide Rods

Monthly

Inspect Hardware

Monthly

Inspect Frame

Bi-Annually

Clean Machine

As Needed

Clean Grips 

1

As Needed

Lubricate Guide Rods 

3

As Needed

1

  Upholstery & Grips should be cleaned with a mild soap 

and water or a non-ammonia based cleaner.

2

  Cables should be inspected for cracks or frays and immediately replaced if present. 

If excessive slack exists cable should be tightened without lifting the head plate.

3

  Guide rods should be lubricated with Teflon based lubricant. Apply the 

lubricant to a cotton cloth and then apply up and down the guide rods.

ENGLISH

TORQUE VALUES

M10 Bolt (Nyloc Nut & Flowdrill)

77 Nm / 57 ft -lbs

M8 Bolts

25 Nm / 18 ft-lbs

M8 Plastic 

15 Nm / 11 ft-lbs

M6 Bolts

15 Nm / 11 ft-lbs

Pad Bolts

10 Nm / 7 ft-lbs

Summary of Contents for MD-S711

Page 1: ...MD S711 MEDICAL LEG EXTENSION LEG CURL ...

Page 2: ...2 ...

Page 3: ... avoid injury INSTALLATION 1 STABLE AND LEVEL SURFACE MATRIX exercise equipment must be installed on a stable base and properly leveled 2 SECURING EQUIPMENT Manufacturer recommends that all stationary MATRIX strength equipment be secured to the floor to stabilize equipment and eliminate rocking or tipping over This must be performed by a licensed contractor 3 Under no circumstances should you slid...

Page 4: ... s leg muscles Recovery Under a doctor s care the medical leg extension leg curl can be used to improve muscle strength after surgery or injury The handrails and seat of the medical leg extension leg curl can be used for additional safety and stabilization of the patient Orthopedic Rehabilitation Under a doctor s care the medical leg extension leg curl can be used for orthopedic rehabilitation e g...

Page 5: ...e the pad to a comfortable start position 2 Back Pad Start Position Pull handle upward adjust the back pad to a comfortable start position release handle Allows the user to adjust the starting position of the back pad The user pulls the outermost handle upwards chooses comfortable start position and then releases handle 3 Seat Pivot Change Pull pin adjust the seat height to correct exercise start ...

Page 6: ...tal weight pins and insert above head plate to achieve desired starting weight 6 Thigh Pad Rotation Pull pin rotate thigh pad out release pin Allows the user to swing the thigh pad out away from the user for easy entrance and exit of the machine 7 Thigh Pad Release Depress lever with thumb raise or lower pad release lever Allows the user to raise or lower the thigh pad into a comfortable start pos...

Page 7: ...ECKLIST ACTION FREQUENCY Clean Upholstery 1 Daily Inspect Cables 2 Daily Clean Guide Rods Monthly Inspect Hardware Monthly Inspect Frame Bi Annually Clean Machine As Needed Clean Grips 1 As Needed Lubricate Guide Rods 3 As Needed 1 Upholstery Grips should be cleaned with a mild soap and water or a non ammonia based cleaner 2 Cables should be inspected for cracks or frays and immediately replaced i...

Page 8: ...sembly confirm all the components by matching them with the exploded diagrams Carefully unpack the unit from this box and dispose of the packing materials in accordance with your local laws Exercise device must be assembled by a trained assembly team or be pre assembled prior to delivery CAUTION To avoid injury to yourself and prevent damage to the frame components be sure to have proper assistanc...

Page 9: ...150L Nylock Nut M10 Bolt M10x105L Bolt M10x80L 2 7 2 12 2 8 2 2 2 A I Step 2 Hardware Description Qty A I Bolt M10x20L Washer Φ10 5xΦ42 1 1 Do not fully tighten frame connectors until assembly is complete Vibra Tite 135 Red Gel or equivalent must be used on all fasteners that are not assembled with Nylock Nuts ENGLISH pre installed pre installed ...

Page 10: ...B A A B D E D F J 3 4 Step 3 Hardware Description Qty J Set Screw ST4x20L 1 Step 4 Hardware Description Qty A B D E F Bolt M10x20L Washer Φ10 2 Arc Washer Φ10 5 Bolt M10x150L Nylock Nut M10 10 8 6 2 2 ENGLISH ...

Page 11: ... Step 2 Hardware Description Qty A B K L M N Bolt M10x20L Washer Φ10 2 Bolt M8x15L Washer Φ8 5xΦ60 Axle Φ25 0x88 POM Washer 41 8xΦ20 5 1 1 1 1 1 2 ENGLISH Step 5 Hardware Description Qty A I Bolt M10x20L Washer Φ10 5xΦ42 1 1 ...

Page 12: ...12 P A R Q O P O B 7 8 Step 7 Hardware Description Qty B O P Washer Φ10 2 Bolt M10x25L Plug 4 6 2 Step 8 Hardware Description Qty A P Q R Bolt M10x20L Plug Bolt M8x25L Washer Φ8 4 2 2 2 2 ENGLISH ...

Page 13: ...Q R Step 10 Hardware Description Qty Q R Bolt M8x25L Washer Φ8 4 4 4 ENGLISH Step 9 Hardware Description Qty A I R S T Bolt M10x20L Washer Φ10 5xΦ42 Washer Φ8 4 Wavy Washer Φ30 5 Nylock Nut M8 1 1 1 1 1 ASSEMBLY COMPLETE ...

Page 14: ...14 OPTIONAL ASSEMBLY SOLD SEPARATELY INCREMENTAL WEIGHTS D C B A STEP STOOL ENGLISH Hardware Description Qty A B C D Plug pre installed Bolt M10x20L Spring Washer Φ10 2 Arc Washer Φ10 2 2 2 2 2 ...

Page 15: ......

Page 16: ...MD S711 2019 Johnson Health Tech Part XXXXXXXXXX Rev 1 1 A ...