Matrix MD-S711 Operating Instructions Manual Download Page 3

3

WARNING

DEATH OR SERIOUS INJURY CAN OCCUR ON THIS 

EQUIPMENT. FOLLOW THESE PRECAUTIONS TO AVOID 
INJURY!

1. Keep children under the age of 14 away from this 

strength training equipment. Teenagers must be 
supervised at all times while using this 
equipment.

2. This equipment is not intended for use by persons 

with reduced physical, sensory or mental 
capabilities, or lack of experience and knowledge, 
unless they have been given supervision or 
instruction concerning use of the equipment by a 
person responsible for their safety.

3. All warnings and instructions should be read and 

proper instruction obtained prior to use. Use this 
equipment for its intended purpose ONLY. 

4. Inspect the machine before use. DO NOT use 

machine if it appears damaged or inoperable.

5. Do not exceed weight capacity of this equipment.
6. Check to see that the selector pin is completely 

inserted into the weight stack.

7. NEVER use the machine with the weight stack 

pinned in an elevated position.

8. NEVER use dumbbells or other means to 

incrementally increase the weight resistance. Only 
use the means provided directly from the 
manufacturer.

9. Injuries to health may result from incorrect or 

excessive training. Cease exercise if you feel faint 
or dizzy. Obtain a medical exam before beginning 
an exercise program.

10. Keep body, clothing, hair, and fitness accessories 

free and clear of all moving parts.

11. Adjustable stops, where provided, must be used 

at all times.

12. When adjusting any adjustable mechanism (stop 

position, seat position, pad location, range of 
motion limiter, pulley carriage, or any other type), 
make certain that the adjustable mechanism is fully 
engaged prior to use to prevent unintended motion.

13. Manufacturer recommends that this equipment be 

secured to the floor to stabilize and eliminate 
rocking or tipping over. Use a licensed contractor.

14. If equipment is NOT secured to floor: NEVER allow 

resistance straps, ropes or other means to be 
attached to this equipment, as this may result in 
serious injury. NEVER use this equipment for 
support during stretching, as this may result in 
serious injury. 

15. DO NOT REMOVE THIS LABEL. REPLACE IF 

DAMAGED OR ILLEGIBLE.

ENGLISH

IMPORTANT SAFETY INFORMATION

It is the sole responsibility of the purchaser 

of MATRIX products to instruct all individuals, 

whether they are the end user or supervising 

personnel on proper usage of the equipment.
It is recommended that all users of MATRIX 

exercise equipment be informed of the 

following information prior to its use. 
Do not use any equipment in any way other than as 

designed or intended by the manufacturer. It is imperative 

that MATRIX equipment be used properly to avoid injury.

INSTALLATION

1.  STABLE AND LEVEL SURFACE: MATRIX exercise equipment 

must be installed on a stable base and properly leveled. 

2.   

SECURING EQUIPMENT: Manufacturer recommends 

that all stationary MATRIX strength equipment 

be secured to the floor to stabilize equipment 

and eliminate rocking or tipping over. This 

must be performed by a licensed contractor.

3.  Under no circumstances should you slide equipment 

across the floor due to risk of tipping. Use proper 

materials handling techniques and equipment 

recommended by OSHA. 

 

All anchor points must be able to withstand 

750 lbs. (3.3 kN) pull-out force.

MAINTENANCE

1.  DO NOT use any equipment that is damaged and or 

has worn or broken parts. Use only replacement parts 

supplied by your country’s local MATRIX dealer. 

2.  MAINTAIN LABELS AND NAMEPLATES: Do not 

remove labels for any reason. They contain 

important information. If unreadable or missing, 

contact your MATRIX dealer for a replacement.

3.  MAINTAIN ALL EQUIPMENT: Preventative maintenance 

is the key to smooth operating equipment as well 

as keeping your liability to a minimum. Equipment 

needs to be inspected at regular intervals. 

4.  Ensure that any person(s) making adjustments 

or performing maintenance or repair of any 

kind is qualified to do so. MATRIX dealers will 

provide service and maintenance training at 

our corporate facility upon request. 

ADDITIONAL NOTES

This equipment should only be used in supervised areas 

where access and control is specifically regulated by the 

owner. It is up to the owner to determine who is allowed 

access to this training equipment. The owner should 

consider a user’s: degree of reliability, age, experience, etc.
This training equipment meets industry standards for 

stability when used for its intended purpose in accordance 

with the instructions provided by the manufacturer.
This equipment is for indoor use only. This training equipment 

is a Class S product (designed for use in a commercial 

environment such as a fitness facility). This training equipment 

is in compliance with EN ISO 20957-1 and EN 957-2.

This equipment has been designed for medical/therapeutic 

use when used under the supervision of a doctor or clinician.

NOTE

1.  Ambient temperature for operating this equipment is 5°C 

- 40°C (with NO air-flow), nominal 25°C.

2.  Relative Humidity for operating this equipment is 10% - 

90% (non-condensing), nominal 40% (non-condensing).

3.  Ambient temperature for shipping and storage this 

equipment is from -20°C to 70°C (with NO air-flow).

4.  The barometric pressure for operating/storage/

transportation of this equipment should be between 

70kPa~106kPa.

5.  Relative Humidity for shipping/storage is 10% - 90% (non-

condensing).

6.  Please dispose of the scrap according to local laws and 

regulations.

 - Operating Instructions

 - Manufacturer 

JOHNSON INDUSTRIES (SHANGHAI) CO., LTD. 

No.4500, Baoqian Rd, Zhuqiao,  

Jiading, Shanghai, China

Summary of Contents for MD-S711

Page 1: ...MD S711 MEDICAL LEG EXTENSION LEG CURL ...

Page 2: ...2 ...

Page 3: ... avoid injury INSTALLATION 1 STABLE AND LEVEL SURFACE MATRIX exercise equipment must be installed on a stable base and properly leveled 2 SECURING EQUIPMENT Manufacturer recommends that all stationary MATRIX strength equipment be secured to the floor to stabilize equipment and eliminate rocking or tipping over This must be performed by a licensed contractor 3 Under no circumstances should you slid...

Page 4: ... s leg muscles Recovery Under a doctor s care the medical leg extension leg curl can be used to improve muscle strength after surgery or injury The handrails and seat of the medical leg extension leg curl can be used for additional safety and stabilization of the patient Orthopedic Rehabilitation Under a doctor s care the medical leg extension leg curl can be used for orthopedic rehabilitation e g...

Page 5: ...e the pad to a comfortable start position 2 Back Pad Start Position Pull handle upward adjust the back pad to a comfortable start position release handle Allows the user to adjust the starting position of the back pad The user pulls the outermost handle upwards chooses comfortable start position and then releases handle 3 Seat Pivot Change Pull pin adjust the seat height to correct exercise start ...

Page 6: ...tal weight pins and insert above head plate to achieve desired starting weight 6 Thigh Pad Rotation Pull pin rotate thigh pad out release pin Allows the user to swing the thigh pad out away from the user for easy entrance and exit of the machine 7 Thigh Pad Release Depress lever with thumb raise or lower pad release lever Allows the user to raise or lower the thigh pad into a comfortable start pos...

Page 7: ...ECKLIST ACTION FREQUENCY Clean Upholstery 1 Daily Inspect Cables 2 Daily Clean Guide Rods Monthly Inspect Hardware Monthly Inspect Frame Bi Annually Clean Machine As Needed Clean Grips 1 As Needed Lubricate Guide Rods 3 As Needed 1 Upholstery Grips should be cleaned with a mild soap and water or a non ammonia based cleaner 2 Cables should be inspected for cracks or frays and immediately replaced i...

Page 8: ...sembly confirm all the components by matching them with the exploded diagrams Carefully unpack the unit from this box and dispose of the packing materials in accordance with your local laws Exercise device must be assembled by a trained assembly team or be pre assembled prior to delivery CAUTION To avoid injury to yourself and prevent damage to the frame components be sure to have proper assistanc...

Page 9: ...150L Nylock Nut M10 Bolt M10x105L Bolt M10x80L 2 7 2 12 2 8 2 2 2 A I Step 2 Hardware Description Qty A I Bolt M10x20L Washer Φ10 5xΦ42 1 1 Do not fully tighten frame connectors until assembly is complete Vibra Tite 135 Red Gel or equivalent must be used on all fasteners that are not assembled with Nylock Nuts ENGLISH pre installed pre installed ...

Page 10: ...B A A B D E D F J 3 4 Step 3 Hardware Description Qty J Set Screw ST4x20L 1 Step 4 Hardware Description Qty A B D E F Bolt M10x20L Washer Φ10 2 Arc Washer Φ10 5 Bolt M10x150L Nylock Nut M10 10 8 6 2 2 ENGLISH ...

Page 11: ... Step 2 Hardware Description Qty A B K L M N Bolt M10x20L Washer Φ10 2 Bolt M8x15L Washer Φ8 5xΦ60 Axle Φ25 0x88 POM Washer 41 8xΦ20 5 1 1 1 1 1 2 ENGLISH Step 5 Hardware Description Qty A I Bolt M10x20L Washer Φ10 5xΦ42 1 1 ...

Page 12: ...12 P A R Q O P O B 7 8 Step 7 Hardware Description Qty B O P Washer Φ10 2 Bolt M10x25L Plug 4 6 2 Step 8 Hardware Description Qty A P Q R Bolt M10x20L Plug Bolt M8x25L Washer Φ8 4 2 2 2 2 ENGLISH ...

Page 13: ...Q R Step 10 Hardware Description Qty Q R Bolt M8x25L Washer Φ8 4 4 4 ENGLISH Step 9 Hardware Description Qty A I R S T Bolt M10x20L Washer Φ10 5xΦ42 Washer Φ8 4 Wavy Washer Φ30 5 Nylock Nut M8 1 1 1 1 1 ASSEMBLY COMPLETE ...

Page 14: ...14 OPTIONAL ASSEMBLY SOLD SEPARATELY INCREMENTAL WEIGHTS D C B A STEP STOOL ENGLISH Hardware Description Qty A B C D Plug pre installed Bolt M10x20L Spring Washer Φ10 2 Arc Washer Φ10 2 2 2 2 2 ...

Page 15: ......

Page 16: ...MD S711 2019 Johnson Health Tech Part XXXXXXXXXX Rev 1 1 A ...