Matrix MB xxx-3U series Specification Download Page 8

8

Outputs

MIN

MAX

Watt               Peak

3.3V

0.0A

     

25.0A              82.5               40.0A

5.0V

1.0A

75.0A           375.0             100.0A

-5.0V

0.0A

  0.5A               2.5                 1.0A

12.0V

0.0A              120.0A         1440.0             130.0A

-12.0V

0.0A

  0.8A

  9.6                 2.0A

5.0Vsb

0.0A

4.00A

20.0                 6.0A

Total = 1500 Watt

Maximum combined wattage of 3.3V and 5.0V  outputs is 375W.

3.3.2 Efficiency

a.

 

The efficiency of the power supply should be met over the AC input range defined
in Table 1, under the load conditions defined in Section 3.3, and under the
temperature and operating conditions defined in Section 5. The power supply should
be a typical of 72% efficient under full load as defined in the applicable
configuration.

b.

The +5Vsb standby supply efficiency should be 65% at 2.0A output. Standby
efficiency is measured with the main outputs off and with PWR_ON high. The AC
input power shall not exceed 8 W when the main outputs are in the "DC disabled"
state with 1.0 A load on +5VSB and the input is 230Vac/50 Hz or 115Vac/60Hz.

3.3.3

 

 Output Ripple/Noise

a.

The following output ripple/noise requirements should be met throughout the load
ranges specified in Section 3.3, and under all input voltage conditions as specified in
Section 3.1.

b.

 

Ripple and noise are defined as periodic or random signals over a frequency band of
10 Hz to 20 MHz. Measurements shall be made with an oscilloscope with 20 MHz
bandwidth. Outputs should be bypassed at the connector with a 0.1 uF ceramic disk
capacitor and a 47 uF electrolytic capacitor to simulate system loading.

              

Table 5: DC Output Noise/Ripple

              Output          Max Ripple & Noise
                                   

(mVpp)

                +12VDC 

120

                +5VDC   

50

                +3.3VDC 

40

                -5VDC  

50

                -12VDC 

120

                +5VSB 

50

3.3.4

 

 Output Transient Response

Summary of Contents for MB xxx-3U series

Page 1: ...Matrix Power Company MB xxx 3U series Specification Document...

Page 2: ...3 1 Output requirement 3 3 2 Efficiency 3 3 3 Output ripple and noise 3 3 4 Output transient response 3 3 5 5Vdc and 3 3Vdc power sequencing 3 3 6 voltage hold up time 3 4 Timing housekeeping control...

Page 3: ...w fan 4 4 Connector 5 Environment requirement 5 1 Environment requirement 5 2 Thermal shook shipping 5 3 Humidity 5 4 Altitude 5 5 Mechanical shock 5 6 Vibration 6 Electromagnetic compatibility 7 Reli...

Page 4: ...over current Protection The power supply shall incorporate primary fusing for input overcurrent protection Fuses should be slow blow type or equivalent to prevent nuisance trips 3 1 3 Inrush Current...

Page 5: ...remote sensing wires to achieve regulation at the output connector to compensate for voltage drop of cable connector and PCB trace If the remote connection is lost to any of these outputs then interna...

Page 6: ...Watt Peak 3 3V 0 0A 25 0A 82 5 35 0A 5 0V 1 0A 35 0A 175 0 45 0A 5 0V 0 0A 0 5A 2 5 1 0A 12 0V 1 0A 56 0A 672 0 62 0A 12 0V 0 0A 0 8A 9 6 1 5A 5 0Vsb 0 0A 4 00A 20 0 5 0A Total 700 Watt Maximum combin...

Page 7: ...ined wattage of 3 3V and 5 0V outputs is 250W Table 4 5 MB1100 VA Power Distribution Configuration Outputs MIN MAX Watt Peak 3 3V 0 0A 25 0A 82 5 40 0A 5 0V 1 0A 55 0A 275 0 80 0A 5 0V 0 0A 0 5A 2 5 1...

Page 8: ...ncy is measured with the main outputs off and with PWR_ON high The AC input power shall not exceed 8 W when the main outputs are in the DC disabled state with 1 0 A load on 5VSB and the input is 230Va...

Page 9: ...50 Hz at maximum continuous output load as applicable for a typical of 17 ms 3 4 Timing Housekeeping Control Figure 1 Power Supply Timing Notes a T2 is defined in Section 3 4 5 b T3 T4 and T5 are defi...

Page 10: ...ly shall also provide debounce circuitry on PWR_ON to prevent it from oscillating on off at startup due to activation by a mechanical switch The DC output enable circuitry must be SELV compliant 3 4 3...

Page 11: ...ge output should remain at its steady state value for the minimum holdup time specified in Section 3 3 6 until it begins to decrease in voltage The decrease shall be monotonic in nature dropping to 0...

Page 12: ...n will be connected to the system chassis by the system components 4 Mechanical requirement 4 1 Label and marking The label must be follow safety UL cUL TUV CE request 4 2 Physical dimensions The supp...

Page 13: ...hanical Shock Nonoperating 50 g trapezoidal input velocity change 170 in s Three drops on each of six faces are applied to each sample Operational The unit will be able to withstand 10g acceleration p...

Page 14: ...er than 100 000 hours under the following conditions a Full load b 230Vac input c Ground benign d 25 C ambient 7 2 Compatibility All versions of the power supply will be backward compatible for form f...

Reviews: