Matrix MB xxx-3U series Specification Download Page 5

5

3.2

 

DC Output Requirements

3.2.1 DC Voltage Regulation

The DC output voltages shall remain within the regulation ranges shown in Table 3 when
measured at the load end of the output connectors under all line, load, and environmental
conditions. The voltage regulation limits shall be maintained under continuous operation
for a period of time equal to or greater than the MTBF specified in Section 7.2 at any
steady state temperature and operating conditions specified in Section 5.

             Table 3: DC Output Voltage Regulation
Output

Range      Min.        Nom.        Max.        Unit

+12Vdc

±

5%       +11.40      +12.00      +12.60       Volts

+5Vdc

+5-4%      +4.80       +5.00       +5.25       Volts

+3.3Vdc

+5-4%      +3.17       +3.30       +3.46       Volts

-5Vdc

±

5%        -4.75       -5.00       -5.25       Volts

-12Vdc

±

10%      -11.40      -12.00      -13.20       Volts

+5Vsb

±

5%        +4.75       +5.00       +5.25       Volts

3.2.2

 

Remote Sensing

a.

 

For the +12V, +5 V and +3.3 V, the power supply shall use remote sensing wires to
achieve regulation at the output connector to compensate for voltage drop of cable,
connector, and PCB trace. If the remote connection is lost to any of these outputs, then
internal resistive feedback causes the power supply to regulate and prevent OVP.

b. The power supply should have remote sense return (Returns) to regulate out ground drops

for all output voltages, +12V, +3.3V, and +5V. The power supply will uses remote sense
(+3.3Vs, +5Vs, +12Vs) to regulate out drops in the system for the +3.3V, and +5V
outputs. Remote sense must be able to regulate out a minimum of 250mV of drop on the
+3.3V and +5V outputs. The remote sense return (Returns) must be able to regulate out a
minimum of 100mV of drop in the power ground return. The current in any remote sense
line shall be less than 10mA to prevent voltage sensing errors. The power supply must
operate within specification over the full range of voltage drops from the power supply's
output connector to the remote sense points.

3.3

 

Power Distribution:

Summary of Contents for MB xxx-3U series

Page 1: ...Matrix Power Company MB xxx 3U series Specification Document...

Page 2: ...3 1 Output requirement 3 3 2 Efficiency 3 3 3 Output ripple and noise 3 3 4 Output transient response 3 3 5 5Vdc and 3 3Vdc power sequencing 3 3 6 voltage hold up time 3 4 Timing housekeeping control...

Page 3: ...w fan 4 4 Connector 5 Environment requirement 5 1 Environment requirement 5 2 Thermal shook shipping 5 3 Humidity 5 4 Altitude 5 5 Mechanical shock 5 6 Vibration 6 Electromagnetic compatibility 7 Reli...

Page 4: ...over current Protection The power supply shall incorporate primary fusing for input overcurrent protection Fuses should be slow blow type or equivalent to prevent nuisance trips 3 1 3 Inrush Current...

Page 5: ...remote sensing wires to achieve regulation at the output connector to compensate for voltage drop of cable connector and PCB trace If the remote connection is lost to any of these outputs then interna...

Page 6: ...Watt Peak 3 3V 0 0A 25 0A 82 5 35 0A 5 0V 1 0A 35 0A 175 0 45 0A 5 0V 0 0A 0 5A 2 5 1 0A 12 0V 1 0A 56 0A 672 0 62 0A 12 0V 0 0A 0 8A 9 6 1 5A 5 0Vsb 0 0A 4 00A 20 0 5 0A Total 700 Watt Maximum combin...

Page 7: ...ined wattage of 3 3V and 5 0V outputs is 250W Table 4 5 MB1100 VA Power Distribution Configuration Outputs MIN MAX Watt Peak 3 3V 0 0A 25 0A 82 5 40 0A 5 0V 1 0A 55 0A 275 0 80 0A 5 0V 0 0A 0 5A 2 5 1...

Page 8: ...ncy is measured with the main outputs off and with PWR_ON high The AC input power shall not exceed 8 W when the main outputs are in the DC disabled state with 1 0 A load on 5VSB and the input is 230Va...

Page 9: ...50 Hz at maximum continuous output load as applicable for a typical of 17 ms 3 4 Timing Housekeeping Control Figure 1 Power Supply Timing Notes a T2 is defined in Section 3 4 5 b T3 T4 and T5 are defi...

Page 10: ...ly shall also provide debounce circuitry on PWR_ON to prevent it from oscillating on off at startup due to activation by a mechanical switch The DC output enable circuitry must be SELV compliant 3 4 3...

Page 11: ...ge output should remain at its steady state value for the minimum holdup time specified in Section 3 3 6 until it begins to decrease in voltage The decrease shall be monotonic in nature dropping to 0...

Page 12: ...n will be connected to the system chassis by the system components 4 Mechanical requirement 4 1 Label and marking The label must be follow safety UL cUL TUV CE request 4 2 Physical dimensions The supp...

Page 13: ...hanical Shock Nonoperating 50 g trapezoidal input velocity change 170 in s Three drops on each of six faces are applied to each sample Operational The unit will be able to withstand 10g acceleration p...

Page 14: ...er than 100 000 hours under the following conditions a Full load b 230Vac input c Ground benign d 25 C ambient 7 2 Compatibility All versions of the power supply will be backward compatible for form f...