Step 1:
Unpacking the Door Controller
1.
Unpack the COSEC DOOR Controller package. The
following items are required to install the door controller:
• COSEC DOOR Controller with accessory kit (included) as
mentioned earlier.
• Matrix COSEC Door PSBB (13.8VDC @ 2 A Universal
Mains PS with Battery Backup) is not included with the
package but has to be ordered separately in the event of a
requirement for battery backup for the COSEC DOOR.
2.
Verify the content for any missing item/part or damaged
component. Any missing or damaged item should be
reported immediately.
Step 2:
Selecting a Mounting Location
The COSEC DOOR Controller should be accessible for ease
of installation and maintenance. The DOOR Controller unit
has inbuilt readers and thus it is mandatory that it should be
installed next to the access point.
Select an ideal location using the following guidelines:
• Stay away from electrical or communication devices:
DOOR Controllers must be located at a minimum distance
of
•
2 m (6 feet) from any high voltage equipment or
wiring (> 230 Volts) and from electrical equipment
susceptible of generating electrical interference
•
1 meter (3 feet) from telephone equipment or lines
•
8 meters (25 feet) from any transmitting equipment.
• The DOOR Controller should be mounted adjacent to the
door providing normal temperature and humidity levels.
• DOOR Controllers should be located adjacent to the
controlled door.
Summary of Contents for Cosec Door
Page 1: ...SE C UR I T Y S OL UT I ON S COSEC DOOR Quick Start ...
Page 2: ......
Page 3: ...COSEC DOOR Door Controller Quick Start S E CUR I TY S OLU T ION S ...
Page 15: ...the following are the connection diagrams for the serial and the wiegand readers ...
Page 22: ...DOOR Mounting Guide ...
Page 30: ......
Page 31: ......