![Matrix Vision mvBlueGEMINI Technical Manual Download Page 31](http://html1.mh-extra.com/html/matrix-vision/mvbluegemini/mvbluegemini_technical-manual_1741404031.webp)
mvBlueGEMINI Technical Manual (EN) v
1.2.2
APPENDIX
-
CONTROL
COMMANDS
30
Start inspection
Is sent to the smart camera to start the inspection. The behavior of the smart camera depends on
the
mvIMPACT Configuration Studio (mvIMPACT-CS)
settings. Untriggered inspections will start
immediately and will transmit results continuously while triggered inspections will wait for a trigger
signal.
Lenght in bytes
Structure
Value
Description
4
uint32
42565350
hex
Magic number
4
uint32
00
hex
User data length in bytes
4
uint32
41
hex
Message ID
Stop inspection
Is sent to the camera to stop an inspection. Untriggered inspections will stop and will not send
results anymore while triggered inspections will ignore further trigger signals.
Lenght in bytes
Structure
Value
Description
4
uint32
42565350
hex
Magic number
4
uint32
00
hex
User data length in bytes
4
uint32
42
hex
Message ID
Restart camera
Restarts the camera. After this message, the network connection will be lost and will be established
after the restart. The restart will take approximately 30 seconds.
Lenght in bytes
Structure
Value
Description
4
uint32
42565350
hex
Magic number
4
uint32
00
hex
User data length in bytes
4
uint32
43
hex
Message ID