2.6 Manual Override
The
Manual Override
is provided to allow the PK202-25 to be reset to factory defaults. This can be
particularly helpful if the display module has been set to an unknown baud rate or I
2
C Slave Address and
you are no longer able to communicate with it. If you wish to return the module to its default settings you
must:
1.
Power off the display module.
2.
Place a Jumper on the
Manual Override
pins.
3.
Power up the display module.
4.
The display module is now set to its default values listed below in
table 2
.
5.
Edit and save settings.
Figure 19: Manual Override Jumper
Table 2: Default Values
Brightness
255
Baud Rate
19.2 kbps
I
2
C Slave Address
0x50
Data Lock
False
RS232AutoTransmitData
True
NOTE
The display module will revert back to the old settings once turned off, unless the
settings are saved.
Matrix Orbital
PK202-25
13