Matrix Orbital MOP-TFT480272-43G-BLM-TPC Hardware Manual Download Page 17

Contact details

2018 version 1.0

The Netherlands

Germany North

Nordic region

Belgium

Germany South

UK & Ireland

Austria

Elektrostraat 17

NL-7483 PG Haaksbergen

T:  +31 (0)53 573 33 33

F:   +31 (0)53 573 33 30

E: [email protected]

Bahnhofstrasse 92

D-25451 Quickborn

T:  +49 (0)4106 627 07-0

F:   +49 (0)4106 627 07-20

E: [email protected]

Sdr. Jagtvej 12

DK-2970 Hørsholm

T:  +45 88 20 26 30

F:   +45 88 20 26 39

E: [email protected]

Zuiderlaan 14 bus 10

B-1731 Zellik

T:  +32 (0)2 462 01 00

F:   +32 (0)2 462 01 25

E: [email protected]

Martin-Kollar-Strasse 9

D-81829 München

T:  +49 (0)89 436 086-0

F:   +49 (0)89 436 086-19

E: [email protected]

St. Mary’s House, Church Lane

Carlton Le Moorland

Lincoln LN5 9HS

T:  +44 (0)1522 789 555

F:   +44 (0)845 299 22 26

E: [email protected]

Warwitzstrasse 9 

A-5020 Salzburg

T:  +43 (0)662 216 026

F:   +43 (0)662 216 026-66

E: [email protected]

General information

[email protected]

www.texim-europe.com

Italy

Via Matteotti 43

IT-20864 Agrate Brianza (MB)

T:  +39 (0)395 967 226

F:   +39 (0)395 967 226

E: [email protected]

Summary of Contents for MOP-TFT480272-43G-BLM-TPC

Page 1: ...MOP TFT480272 43G BLM TPC Hardware Manual Revision 1 1...

Page 2: ...1 MOP TFT480272 43G BLM TPC Revision History Revision Date Description Author 1 1 March 29 2018 Updated Naming Convention Divino 1 0 May 26 2017 Initial Release Divino...

Page 3: ...ming 9 10 Power Sequence 10 10 1 Power Up Sequence 10 10 2 Power Down Sequence 10 11 Inspection Criterion 11 11 1 Description 11 11 2 Sample plan 11 11 3 Inspection condition 11 11 4 Definition of ins...

Page 4: ...ics DC Characteristics at Ta 25 C Item Symbol Min Typ Max Unit Power Supply Input Voltage VDD 3 0 3 3 3 6 V I O logic voltage VDDIO 1 8 3 3 V Input voltage H level VIH 0 7VDD VDD V Input voltage L lev...

Page 5: ...iption IC solution on TP Model GT911 Touch Count Max 5 point Display Resolution 480 272 Interface Type I2C I2C Slave Address 0x5D Origin of Coordinate Top left corner Parameter Min Typ Max Unit Interf...

Page 6: ...5 MOP TFT480272 43G BLM TPC 6 External Dimensions Figure 1 MOP TFT480272 43G BLM TPC Drawing...

Page 7: ...inition of Viewing angle Viewing angle is the angle at which the contrast ratio is greater than 10 The angles are determined for the horizontal or x axis and the vertical or y axis with respect to the...

Page 8: ...Red data 13 20 Green 0 7 I Green data 21 28 Blue 0 7 I Blue data 29 GND I Ground 30 PCLK I Dot clock signal 31 DISP I Display on off 32 HSYNC I Horizontal sync input 33 VSYNC I Vertical sync input 34...

Page 9: ...Clock rising time Trck 9 ns Clock falling time Tfck 9 ns HSD width Thwh 1 DCLK HSD period time Th 55 60 65 s HSD setup time Thsu 12 ns HSD hold time Thhd 12 ns VSD width Tvwh 1 Th VSD setup time Tvsu...

Page 10: ...rameter Symbol Value Unit Min Typ Max DCLK frequency fclk 5 9 12 MHz VSD period time Tv 277 288 400 H VSD display area Tvd 272 H VSD back porch Tvb 3 8 31 H VSD front porch Tvfp 2 8 97 H HSD period ti...

Page 11: ...MOP TFT480272 43G BLM TPC 10 10 Power Sequence 10 1 Power Up Sequence Figure 5 Power On Sequence 10 2 Power Down Sequence Figure 6 Power Off Sequence...

Page 12: ...using the voltage level Within r0 5V of the typical value at 25qC that provides the most optical contrast 11 4 Definition of inspection zone in LCD Figure 7 Inspection Zones in an LCD Zone A characte...

Page 13: ...D a b 2 0 1 D 0 2 4 0 2 D 0 3 0 0 3 D 0 5 0 D 0 5 0 the distance between the two defect dot DS 5mm line defect Length mm Width mm Judgement Criterion disregard W 0 05 allowed L 5 0 05 W 0 1 4 L 5 W 0...

Page 14: ...input terminal to VDD or VSS x Do not input any signals before power is turned on x Ground your body work assembly areas and assembly equipment to protect against static electricity 12 4 Packing The m...

Page 15: ...e the display in a polyethylene bag with the opening sealed x Ensure that nothing is making contact with the polarizer surface x It is recommended to store them in the same packaging that was provided...

Page 16: ...ur Hundred Eighty Pixel Columns 4 Display Rows 272 Two Hundred Seventy Two Pixel Rows 5 Display Size 43 4 3 6 Display Form Factor G G Form Factor 7 Brightness Level BLS Brightness 300 Nit BLM 300 Nit...

Page 17: ...om Zuiderlaan 14 bus 10 B 1731 Zellik T 32 0 2 462 01 00 F 32 0 2 462 01 25 E belgium texim europe com Martin Kollar Strasse 9 D 81829 M nchen T 49 0 89 436 086 0 F 49 0 89 436 086 19 E germany texim...

Reviews: