OPTOISOLATED INPUTS 

 

 

 

Those inputs are opto-isolated, DRY contact. 
 

If connected to ground GND the value will be a “0”. If open, it will be “1”. We recommend that you do not 

apply any voltage.  If you do, do not exceed 12V. 

 

3.7.5. Analog-to-Digital Converter (ADC

)

 

 

The MTX-IND-V2 has 2 Analog to Digital converters that can be configured to connect to measure voltages 

and also to connect current sensors. They can be configured with internal JUMPERs. 

 

 

Terminal block 

FUNCTION 

 

Max Values 

 

33 

VEXT 

Output voltage  

3V 50mA 

Direct from TC65i 

34 

DAC OUT 

Output PWM  

0-3V 

Direct from TC65i 

35 

ADC2 

Configurable 0-20mA 

0-2.4 

AD2 TC65i 

36 

ADC1 

Configurable 0-20mA 

0-2.4 

AD1 TC65i 

37 

AGND 

 

 

Analog ground for 
ADC1 & ADC2 

 

 
By default, the ADC of the MTX-IND-V2 consists of 2 independent, unbalanced, multiplexed analog inputs 

that can be used for measuring external DC voltages in the range of 0mV…+2400mV. The ADC has a 

resolution of 12 bits. 

 

It can be configured to measure currents 4-20 mA range. It’s intended to connect to 4-20mA type sensors. 

 

Jumper 

Terminal joined 

ADC 

Mode 

JPu1 

1-2 joined 

ADC1 

4-20mA (20mA = 2,4V ADC). 

JPu1 

3-4 joined 

ADC1 

4-20mA (20mA = 2,4V ADC). 

 

Terminal block number 

Input number 

TC65i GPIO 

Terminal block 38  

IN10 

(GPIO10 TC65i) 

Terminal block 39  

IN9 

(GPIO9 TC65i) 

Terminal block 40  

IN8 

(GPIO8 TC65i) 

Terminal block 41  

IN4 

(GPIO4 TC65i) 

Summary of Contents for 199801099

Page 1: ...RS terminal modem http www matrix es MTX IND V2 User Manual V 1 1 Page 1 Subject to change without prior notice MTX IND V2 INDUSTRIAL FEATURED IP65 JAVA GSM GPRS TERMINAL User Manual Powered by CINTER...

Page 2: ...mages for loss of business profits business interruption loss of business information or data or other pecuniary loss arising out the use of or inability to use the documentation and or product even i...

Page 3: ...Y SERIAL INTERFACE ASC1 23 3 7 4 General Purpose IO 26 3 7 5 Analog to Digital Converter ADC 28 3 7 6 Real Time Clock 29 3 7 7 DAC PWM 29 3 8 Software Updates 29 4 Operation 30 4 1 Switching On the Mo...

Page 4: ...Band Antenna 900 1800MHz Error Marcador no definido 8 2 2 Right angle short antenna Error Marcador no definido 8 2 3 Patch Adhesive Antenna Error Marcador no definido 8 3 CABLES Error Marcador no def...

Page 5: ...e components and making your M2M application easy to integrate RF 868MHz radio frequency WaveCard Coronis modules can be connected to the internal TC65i ASC1 port to create an RF network and concentra...

Page 6: ...C500 V2 0 199801122 1 500 mW 2 opto IO 4 opto IN 2 Analog IN 4 YES MTX IND WC25 V2 0 low cost TBD 1 25 mW NO MOQ MTX IND WC500 V2 0 low cost TBD 1 500 mW NO MOQ MTX IND WC500 ETH V2 0 TBD 0 500 mW YES...

Page 7: ...an provide a PWM signal o 1 x I2C SPI bus o Power supply 220 VAC General Features IP65 housing Quad Band GSM 850 900 1800 1900 MHz JAVA J2ME programmable GPRS multi slot class 12 GSM release 99 Output...

Page 8: ...c hands free operation Echo cancellation Noise reduction Short Message Service SMS Features Point to point MO and MT SMS cell broadcast Text and PDU mode Internet Protocols TCP UDP IP protocol stack E...

Page 9: ...station represents the wireless modem and SIM card The wireless modem excluding SIM card is known as the ME mobile equipment The DTE data terminal equipment is the controlling application This can be...

Page 10: ...d by the host application 1 4 3 Data The wireless modem supports the following data protocols GPRS General Packet Radio Service The wireless modem is a Class B terminal The wireless modem is GPRS mult...

Page 11: ...ved Power consumption depends on network settings and GPRS configuration e g multi slot settings GPRS DATA GPRS data transfer in progress Power consumption depends on network settings e g power contro...

Page 12: ...wer level Low Power mode uA Power Down mode stand by mA SLEEP mode mA IDLE mode mA TALK mode mA Data GPRS 1Tx 4Rx mA Data GPRS 2Tx 3Rx Power reduction 3dB mA Data GPRS 4Tx 1Rx Power reduction 6dB mA I...

Page 13: ...ce 1 4 7 SIM Card The MTX IND V2 supports the SIM card through the integrated SIM holder Both 3V and 1 8V SIM technology is supported Older 5V SIM technology is not supported 2 MECHANICAL DESCRIPTION...

Page 14: ...ge 14 Subject to change without prior notice HOUSING BOPLA ET 221 Euromas II Product no 63221000 Width 120 mm Height 77 mm Length 200 mm Material 1 ABS acrylonitrile butadiene styrene Kunststoff Seali...

Page 15: ...na 16 RL7 nc 17 IN5 OUT5 IN OUT GPIO5 18 IN5 OUT5 19 IN6 OUT6 IN OUT GPIO6 20 IN6 OUT6 21 GND 22 SIM HOLDER 23 SIM HOLDER 24 SIM HOLDER 25 SIM HOLDER 26 SIM HOLDER 27 USB Sync LED J9 Connector for ext...

Page 16: ...tdown feature This allows an application to always be switched on it will be able to restart by itself The terminal will not need an external ignition to be powered up and it will be powered up 100 ti...

Page 17: ...vailable as a command and data interface and for downloading firmware The USB I O pins are capable of driving the signal at min 3 0V They are 5V I O compliant To properly connect the module s USB inte...

Page 18: ...st unplug the U FL connector from Cinterion TC65i and plug the U FL connector into an internal antenna We recommend EAD QUINTUS but other models are available The external antenna must be matched prop...

Page 19: ...es on a SIM card being inserted Some MTX IND V2 functionality may be lost if you try to operate the control terminal without a SIM card 3 6 MAIN Serial Interface Port ASC0 RS232 RS485 RS422 The modem...

Page 20: ...TX IND V2 Industrial Featured GSM GPRS terminal modem http www matrix es MTX IND V2 User Manual V 1 1 Page 20 Subject to change without prior notice Internal JUMPER CONFIGURATION Location for JPC1 JPC...

Page 21: ...JPC1 JP 1 2 Open No Res JP 3 4 Open JP 5 6 Open JP 7 8 Open JPC3 JP 1 2 Close RS 485 Bus ended with 120 ohm resistor 2 Wires JPC1 JP 1 2 Close Res 120 JP 3 4 Open JP 5 6 Open JP 7 8 Open JPC3 JP 1 2...

Page 22: ...controlling the GSM engine with AT commands Full Multiplex capability allows the interface to be partitioned into three virtual channels but with CSD and fax services only available on the first logic...

Page 23: ...k pins shown below The modem supports by default a RS485 serial interface Can be changed to RS232 and RS422 interfaces with internal jumpers selectors RS485 and RS422 buses can be configured as open b...

Page 24: ...Received data 45 CTS O Min 5V Clear to send 46 RTS I VILmax 0 6V VIHmin 2 4V VImax 25V Request to send RS232 Features It includes the data lines TD1 and RD1 and the status lines RTS1 and CTS1 It only...

Page 25: ...open bus JPC2 JP 1 2 Open No Res JP 3 4 Open JP 5 6 Open JP 7 8 Open JPC4 JP 1 2 Close RS 485 Bus ended with 120 ohm resistor JPC2 JP 1 2 Close Res 120 JP 3 4 Open JP 5 6 Open JP 7 8 Open JPC4 JP 1 2...

Page 26: ...olated differential input Maximum Voltage IO5 and IO5 30V Terminal block 19 20 INPUT OUTPUT IO6 Terminal Block 19 IO6 Terminal Block 20 IO6 Optoisolated This I O can be configured by JUMPERS as an inp...

Page 27: ...D V2 Terminal provides a flexible general purpose GPIO pins at the terminal block The signal direction input output are defined in the MTX IND V2 due to their internal opto isolated components Be sure...

Page 28: ...tput voltage 3V 50mA Direct from TC65i 34 DAC OUT Output PWM 0 3V Direct from TC65i 35 ADC2 Configurable 0 20mA 0 2 4 AD2 TC65i 36 ADC1 Configurable 0 20mA 0 2 4 AD1 TC65i 37 AGND Analog ground for AD...

Page 29: ...ed during sample time ts 400 s 3 7 6 Real Time Clock The TC65i module inside of the MTX IND V2 contains a real time clock RTC to maintain accurate timekeeping and to enable time stamping of messages T...

Page 30: ...T SSYNC 1 or AT SSYNC 2 factory default mode LED Status AT SSYNC 0 SYNC mode Enables the SYNC pin to indicate growing power consumption during a transmit burst You can make use of the signal generated...

Page 31: ...ess Same as for AT SSYNC 1 Permanently on Depending on type of call Voice call Connected to remote party Data call Connected to remote party or exchange of parameters while setting up or disconnecting...

Page 32: ...attery should be disconnected when shipped from factory Connect it to JPh1 connector The 2 signaling LEDS will operate as follows DL1 GREEN will be ON when mains power is applied and it will be OFF wh...

Page 33: ...ay the customer application can be reduced because all the resources Microcontroller Flash RAM memory all kind of I Os and bus peripheral is allowed to be used by the customer This solution saves the...

Page 34: ...ly For outdoor use it must be integrated into a weatherproof enclosure Do not exceed the environmental and electrical limits as specified in Technical Data Avoid exposing the modem to lit cigarettes n...

Page 35: ...d comprehensive international safety guidelines developed by scientific organizations e g ICNIRP International Commission on Non Ionizing Radiation Protection and IEEE The Institute of Electrical and...

Page 36: ...possible communication disturbances can be found in section 7 3 5 When an application is completed you can verify signal strength by issuing the AT command AT CSQ See AT CSQ Signal Strength Tip Befor...

Page 37: ...ents The antenna must be designed for the one of the frequency bands in use please ask your network provider for more information GSM 850 900 MHz GSM 1800 1900 MHz The impedance of the antenna and ant...

Page 38: ...ntal attenuation of radio signals caused by hills buildings trees or even vehicles This can be a particular problem inside buildings especially if the walls are thick and reinforced Multi path fading...

Page 39: ...in electrical and electronic equipment RoHS STANDARDS of EUROPEAN TYPE APPROVAL 3GPP TS 51 010 1 Digital cellular telecommunications system Phase 2 Mobile Station MS conformance specification ETSI EN...

Page 40: ...limit in 47 CFR 1 1310 we get the value of the maximum antenna gain as follow The maximum measured power output in the 850 MHz band is 1866 38 mW 32 71 dBm see 7layers test report MDE_Siem_0714_FCCb T...

Page 41: ...bol applied on our products and or on its packaging indicates that this product should not be treated as household waste when you wish to dispose of it Instead it should be handed over to an applicabl...

Page 42: ...Electro Magnetic Compatibility ETSI European Telecommunication Standards Institute FR Full Rate GPRS General Packet Radio Service GSM Global System for Mobile Communication HR Half Rate HSCSD High Sp...

Page 43: ...ady DTR function mode AT F Set all current parameters to manufacturer defaults AT S Set circuit Data Set Ready DSR function mode AT V Display current configuration AT W Stores current configuration to...

Page 44: ...dentification Presentation AT CLIR Calling line identification restriction AT CLVL Loudspeaker volume level AT CMEE Mobile Equipment Error Message Format AT CMER Mobile Equipment Event Reporting AT CM...

Page 45: ...MP Set SMS text Mode Parameters AT CSMS Select Message Service AT CSNS Single Numbering Scheme AT CSQ Signal quality AT CSSN Supplementary service notifications AT CUSD Supplementary service notificat...

Page 46: ...MR Read Concatenated Short Messages AT SCMS Send Concatenated Short Messages AT SCMW Write Concatenated Short Messages to Memory AT SCNI List Call Number Information AT SCPIN Pin Configuration AT SCPO...

Page 47: ...S List SMS Memory Storage AT SM20 Set M20 compatibility mode AT SMGL List Short Messages from preferred store without setting status to REC READ AT SMGO Set or query SMS overflow presentation mode or...

Page 48: ...T Indicate SIM data ready AT SSIO Set IO state of a specified pin or port AT SSMSS Set Short Message Storage Sequence AT SSPI Serial Protocol Interface AT SSTA SAT Interface Activation AT SSTGI SAT Ge...

Page 49: ...ngs before automatically answering a call ATS0 Automatic response to a network request for PDP context activation ATS10 Set disconnect delay after indicating the absence of data carrier ATS18 Extended...

Page 50: ...s MTX IND V2 User Manual V 1 1 Page 50 Subject to change without prior notice 13 SALES CONTACT www mtx terminals com gsmsupport matrix es Matrix Madrid Matrix Electronica S L U C Alejandro S nchez 109...

Page 51: ...TX REMOTE UNITS Ordering Codes 202000391 MTX Wavesense 4 20mA 220Vac 1 Analog 4 20mA input Sensor 4 20mA Sensor 0 5V 202000394 MTX WaveTherm PT100 220Vac For measuring temperature Need DALLAS probe or...

Reviews: