Display overall total (fixed):
from 0 to 999,999 (6 characters)
Calibrating the meter display
The MATO built in flow meter is set to a standard medium.
It might thus be necessary for the display of the meter to be calibrated.
Warranty:
If the operating instructions are complied with and the equipment used in accordance with the
directions, we accept liability within the bounds of the statutory warranty obligation.
When making warranty claims always attach the invoice from your dealer, giving the date of purchase
Disposal:
After termination of use the device is to be disposed of in an environmentally friendly manner in
accordance with applicable statutory provisions.
The applicable regulations for the registration, installation and operation of equipment for
handling of substances hazardous to water are to be strictly observed by the operator (such
as, e.g., Federal Water Act, German Ordinance on Exposure to Substances Hazardous to
Waters and Technical Rules and Regulations for Flammable Liquids).
8
N.B.:
The setting screw for calibration of the display
is under the sealing plug.
Meter reading too
high:
Turn setting screw
anti-clockwise
Meter reading too
low:
Turn setting
screw clockwise