6 Tips for fault diagnostics:
Symptom
Possible cause
Rectification
Device
does not
discharge
any oil.
The container is empty.
The oil supply has been
interrupted.
There is a lack of air
pressure.
Faulty pump
Check the level of the
container.
Vent the pump.
Check supply line.
Replace pump.
Device is
producing
too little oil.
Suction screen is clogged
Filter at air inlet is clogged
Filter in the handle of the
gun nozzle is clogged
Connection pressure is too
low
Clean suction screen
Clean filter (see
picture) Clean filter
Correct pressure
settings
7 Specifications:
Pressurised air pump pneuMATO
1
3
5
Pressure transfer
Max. delivery pressure at 8 bar air connection
pressure
Max. delivery performance under free discharge
Air pressure min./max.
Volume level:
1:1
8 bar
ca. 25 l/min
3 – 8 bar
ca. 85
dB(A)
1:3
24 bar
ca. 18 l/min
3 – 8 bar
ca. 85
dB(A)
1:5
40 bar
ca. 17 l/min
3 – 8 bar
ca.85
dB(A)
Medium temperature (depending on the material
properties)
-18°C bis +50°C
Thread
Air connection
Oil outlet
Oil inlet
Rp ¼“
R ½“
Rp ¾“
Rp ¼“
R ½“
Rp ¾“
Rp ¼“
R ½“
Rp ¾“
Measurement A
Measurement B
Measurement C
Measurement D
Measurement E
78 mm
290 mm
75 mm
53 mm
33 mm
78 mm
285 mm
60 mm
53 mm
33 mm
94 mm
295 mm
60 mm
53 mm
33 mm
Weight
3.6 kg
3.5 kg
4.4 kg
Viscous media:
Motor oil, gear oil, lubricating and hydraulic oil (mineral based), biodegradable oils.
Viscous media including Hazard Class A3 can be supported.
Viscous media of Hazard Classes A1 and A2 can
not
be supported.
8 Disposal
After termination of use the device is to be disposed of in an environmentally
friendly manner in accordance with applicable statutory provisions.
Oil-tainted parts do not belong in the dustbin!
The applicable regulations for the registration, installation and operation of
equipment for handling of substances hazardous to water are to be strictly
observed by the operator (such as, e.g., Federal Water Act, German Ordinance on
Exposure to Substances Hazardous to Waters and Technical Rules and
Regulations for Flammable Liquids).
Air filter