background image

021-03 - Electric pasta cooker

5

2 - CHARACTERISTICS OF THE APPLIANCES

3 - TECHNICAL DATA

0051

TIPO/TYPE

CAT/KAT

GAS/GAZ

G30

G31

G20

G25

II2H3B/P

P mbar

30

30

20

-

II2H3+

P mbar

30

37

20

-

-

II2H3+

P mbar

28

37

20

-

25

II2L3B/P

P mbar

30

30

II2ELL3B/P

P mbar

50

50

20

20

II2E+3+

P mbar

28

37

20

25

II2H3B/P

P mbar

50

50

20

-

I2E

P mbar

-

-

20

-

-

-

II2H3B/P

P mbar

30

30

II2H3+

P mbar

28

37

20

-

-

-

-

-

I3B/P

P mbar

30

30

I3+

P mbar

28

37

SE

FI

DK

CZ

SK

SI

IT

CH

PT

ES

IE

GB

GR

NL

DE

FR

BE

AT

CH

LU

EE

LV

LT

EE

LV

LT

NO

MT

CY

IS

HU

CY

MOD.

MOD.

ART.

N.

N.

Qn kW

m

3

/h

MADE IN ITALY 

Predisposto a gas: - Gas preset: - Prevu pour gaz:

Eingestelt für Gas: - Preparado para gas: - Geschuckt voor: 

V AC  

kW

Hz

THE APPLIANCE MUST BE CONNECTED IN COMPLIANCE WITH THE LAWS IN FORCE
AND INSTALLED IN A WELL-VENTILATED ROOM. READ THE INSTRUCTION MANUALS
BEFORE INSTALLING AND USING THE APPLIANCE.
THE APPLIANCE MUST BE INSTALLED BY QUALIFIED PERSONNEL.

These appliances are used for professional purposes. 
Installation, repair and use must be carried out by expert 
personnel.

T h e   d a t a   p l a t e   i s   l o c a t e d   o n   t h e   f r o n t   p a r t   o f   t h e  
appliance (on the control panel).

Model

ACE00008

ACE00004

ACE00006

ACE00003

Dim.: LxWxH

400 x 655 x 300 (400)

600 x 655 x 300 (400)

400 x 700 x 300 (400)

600 x 700 x 300 (400)

400 x 700 x 875 (1080)

600 x 700 x 875 (1080)

Voltage rating

430V 3N / 230 V 3 AC

430V 3N / 230 V 3 AC

430V 3N / 230 V 3 AC

430V 3N / 230 V 3 AC

430V 3N / 230 V 3 AC

430V 3N / 230 V 3 AC

Power

4.5 kW

7.5 kW

4.5 kW

7.5 kW

4.5 kW

7.5 kW

Baskets

2

3

2

3

2

3

Lead wire / Section

4 x 2.5 mm

 / 5 x 1.5 mm

2  

4 x 2.5 mm

 / 5 x 1.5 mm

2  

4 x 2.5 mm

 / 5 x 1.5 mm

2  

4 x 2.5 mm

 / 5 x 1.5 mm

2  

4 x 2.5 mm

 / 5 x 1.5 mm

2  

4 x 2.5 mm

 / 5 x 1.5 mm

2  

Summary of Contents for ACE0003

Page 1: ...021_03 Instructions for installation use and maintenance ELECTRIC PASTA COOKER 04 2006 ACE0003 ACE0004 ACE0006 ACE0008 ...

Page 2: ...ipotential 6 Connection to waterworks 6 Using the appliance 7 Ignition 7 Emptying the bath 7 Taking care of the appliance frequency of maintenance 7 Daily cleaning 7 Precautions during use 8 Protection of stainless steel 8 What to do if not using the appliance for a long time 8 What to do if something goes wrong 8 Maintenance 8 WEEE Directive 8 Wiring diagrams 9 Warning 10 INDEX ...

Page 3: ...pprox 68 5 kg C B D E A 100 21 600 700 170 1080 875 Weight approx 30 2 kg 55 55 21 A D B C Water inlet ø 12 600 655 400 300 55 55 21 600 700 500 300 A D B C E E ACE00004 Weight approx 30 2 kg A B C D Water filling tap Load lever Switch Water autlet E Pilot lamp ...

Page 4: ...ox 23 kg 55 Water inlet ø 12 655 300 55 700 300 A E B C A E B C A E B C D G F 55 21 400 400 70 21 G F D 55 21 400 400 70 21 G F D 130 160 130 80 D G F D F G ACE00008 Weight approx 25 3 kg A B C D Water filling tap Load lever Swicht Water outlet 1 2 gas M E Pilot lamp F Electric connection EL G Water inlet ø 12 ...

Page 5: ... FORCE AND INSTALLED IN A WELL VENTILATED ROOM READ THE INSTRUCTION MANUALS BEFORE INSTALLING AND USING THE APPLIANCE THE APPLIANCE MUST BE INSTALLED BY QUALIFIED PERSONNEL These appliances are used for professional purposes Installation repair and use must be carried out by expert personnel The data plate is located on the front part of the appliance on the control panel Model ACE00008 ACE00004 A...

Page 6: ...liance with all local standards and regulations The manufacturers decli ne all responsibility where poor performance is due to in correct installation in disregard of the above conditions Warning In compliance with international regulations when connecting the appliance to the mains power supply a device with a minimum aperture of 3 mm between con tacts must be fitted upstream of the appliance al ...

Page 7: ...be used provided they do not contain abrasives or chlorine based sub stances such as sodium hypochlorite bleach hydroch loric acid muriatic acid or other solutions stainless steel is quickly and irreversibly corroded by these products Under no circumstances use the above mentioned pro ducts to clean the floor under the equipment or nearby as fumes or any drops may produce similar destructive ef fe...

Page 8: ...of the appliance and call the aftersales depart ment MAINTENANCE All maintenance should be carried out by qualified per sonnel only Before carrying out any maintenance work unplug the appliance or turn off the switch upstream of the appliance 021 03 Electric pasta cooker 8 THE 2002 96 EC DIRECTIVE WEEE information to users This informational note is meant only for owners of equipment marked with t...

Page 9: ...3 P1 P2 H1 L3 L3 L2 L1 mA B1 1 2 3 P4 5 1 2 3 4 P3 P1 P2 400V 3N 230V 3 H1 Lamp mA Terminal board B1 Main swicht green light R1 Resistence MODEL ACE00008 ACE00006 ACE00004 ACE00003 POWER 4 5kW 7 5kW 3 X X X X X 2 X X X X 1 X X X 0 B1 5 1 2 3 4 P4 P3 P1 P2 Wiring diagram ...

Page 10: ...NACCURACIES IN THIS BOOKLET DUE TO COPYING OR PRINTING ERRORS DUE TO ITS POLICY OF CONTINUAL PRODUCT IMPRO VEMENT THE MANUFACTURER RESERVES THE RIGHT TO MAKE ANY CHANGES DEEMED NECESSARY THE MANUFACTURER CANNOT BE HELD RESPONSI BLE IF THE INSTRUCTIONS CONTAINED IN THIS MA NUAL ARE NOT OBSERVED ...

Reviews: