www.masterweld.co.uk
TIG Welding Guide Ranges
Electrode diameter
DC current (amps)
0.040" (1.0mm)
30 – 60
1/16" (1.6mm)
60 – 115
3/32" (2.4mm)
100 – 165
Tungsten Electrode Types
Electrode
type
Welding application
Colour
code
Thoriated
2%
DC welding of mild steel, stainless
steel and copper. Excellent arc
starting, long life, high current
carrying capacity.
RED
Ceriated
2%
DC welding of mild steel, stainless
steel, copper, aluminium, their alloys
longer life, more stable arc, easier
starting, wider current range, narrower
more concentrated arc
GREY
Guide for Selecting Filler Wire Diameter
Filler wire
diameter
DC current range
1/16" (1.6 mm)
20 - 90
3/32" (2.4 mm)
65 - 115
1/8" (3.2 mm)
100 - 165
3/16" (4.8 mm)
200 - 350
The filler wire diameter specified is a guide only, other diameter
wires may be used according to the welding application.
Shielding Gas Selection
Alloy
Shielding gas
Aluminium & alloys
Pure Argon
Carbon steel
Pure Argon
Stainless steel
Pure Argon
Nickel alloy
Pure Argon
Copper
Pure Argon
Titanium
Pure Argon
15