USER INTERFACE
CODE
SYMBOL
DESCRIPTION
L1
When this LED illuminates the following parameter can be set: WIRE FEED RATE
The value appears on the following display: D1
L2
When this LED illuminates the following parameter can be set: WELDING CURRENT
The value appears on the following display: D1
L3
This LED illuminates to show an anomaly in the operating conditions.
An alarm message appears on the following display: D1-D2
§ 9 ALARMS MANAGEMENT
L4
When this LED illuminates the following parameter can be set: WELDING THICKNESS
(Reference is made to "T" fillet welds on identical thicknesses. The relative value is purely guideline).
The value appears on the following display: D1
L5
When this LED illuminates the following parameter can be set: WELDING PROGRAM
The value appears on the following display: D1
L6
Illuminates to show the last voltage and current values measured during welding.
The LED switches off when a new welding procedure is started, or when any of the welding settings is modified.
The value appears on the following displays: D1-D2
L7
Illuminates to show a value in the following unit of measurement: METRES PER MINUTE
Illuminates together with the following LED:
The value appears on the following display: D1
L8
Illuminates to show a value in the following unit of measurement: AMPERES
The value appears on the following display: D1
L9
Illuminates to show a value in the following unit of measurement: MILLIMETRES
Illuminates together with the following LED:
The value appears on the following display: D1
L10
This LED illuminates to confirm the presence of power on the output sockets.
L11
Illuminates to show that the cooling unit pressure switch does not detect any pressure.
L12
Illuminates to show a value in the following unit of measurement: SECONDS
The value appears on the following display: D2
L13
Illuminates to show a value in the following unit of measurement: VOLTS
The value appears on the following display: D2
L14
Illuminates to show a value in the following unit of measurement: PERCENTAGE
The value appears on the following display: D2
L15
Illumination shows that the following function has been activated: 2 times procedure
§ 13.1 2T MIG/MAG WELDING
Summary of Contents for 321 HDP
Page 1: ...17 03 2014 v2 2 ENGLISH 0 MasterWeld 321 HDP Instruction manual GB...
Page 2: ...17 03 2014 v2 2 ENGLISH 0...
Page 8: ...17 03 2014 v2 2 ENGLISH 0...
Page 22: ...17 03 2014 v2 2 ENGLISH 0 22 30 15 SPARE PARTS 15 1 321 HDP...
Page 24: ...17 03 2014 v2 2 ENGLISH 0 24 30 15 2 WIRE FEEDER MOTOR...
Page 26: ...17 03 2014 v2 2 ENGLISH 0 26 30 16 ELECTRICAL DIAGRAM 16 1 321 HDP...