CAUTION

These products fully comply to the latest CE

norms in force from Januari 1st 1996 and are

produced to ISO 9001 standards.

ISO 9001

1.  Lethal voltages exist on your vessel. Make sure all shore power, onboard
     generating sources and batteries are disconnected before beginning
     installation of your electrical panel.

2.  AC modules will have lethal voltages on the bus bars and terminals. The
     coating on these bars is for identification only and should not be relied on 
     as  a insulator.

     Additional safety enclosures may be required in some installations.

3.  Make sure all AC modules are bonded to the shipís AC ground bus. When
      grouping modules together to form your panel, a single ground may be used. 
     Use a resistance meter to verify ground to all modules.

The basic remote panel is a useful power device for remote 
control of the Mass an Ivo smart Mastervolt battery chargers. 
The basic remote control does indicate the status of the charge
 control by six high power leds. 
The remote control is easy to install by a plug-in standard 
twisted six pole RJ45 telephone plug between the analog 
output of the charger and the panel. The communication of  the
remote control and charger is based on analog technology.
The remote panel can be used as an interface for a custom 
made panel or for a dual remote indicator.
The basic remote panel has a combined CSI-DC/alarm
(csi=charger status interface).
The potential free change-over contacts indicate if the
charger is ON or in general failure. The DC alarm set
points can be adjusted in the chargers by use of the
adjustment interface.

The basic remote panel

Specifications

Remote cable:
Connector                        RJ45, 6 pole, male
Max length                      6 meter, max
Type                                 twisted wire

External led drive:
Imax                                5 mA
Umax                               2,5V

General CSI alarm
Max rating                      1 Amp, 30 VDC
NC-on        When the charger is off or the charger is in
                  failure, the normally closed contact is closed
C                Common
NO-on       When the charger is on and no-failure is 
                 indicated the normally open contact is closed
Connectors                     0,75 mm2

MASTERVISION  MODULAR SWITCHBOARDS

panel code

part number

C-4-RB

07-04-04100

DC low on            10.0           20.0           VDC
DC low off            11.0           22.0           VDC

DC high on           16.0           32.0           VDC

Delay time              30              30             SEC   

                                    12V           24V

DC high off           15.0           30.0           VDC

Combined CSI failure and DC high/low alarm

Bat TC failure                   Battery temperature sensor out of range <20

°

C & >60

°

C

Voltage sense failure        Voltage sense out of range >3 VDC
Sys. temp. failure             Charger is out of temperature range ìoverloadî (>75--85  C)
Short break indicator       Charger in reduced current mode (short break mode) Uout <4..5VDC

DC alarm                          Battery range out of range (with standard setting of charger)

on

failure

Inverter Control

on

failure

float

bulk

absorption

Charger Control

Charger Output

current control

on

failure

float

bulk

absorption

Charger Control

on - bulk charge

failure

float

absorption

Charger Control

for Mass & IVO smart chargers

60 x 65 mm
40 mm

description:
type:

dimensions panel (wxh):
panel depth:

SPECIFICATIONS

remote basic charger control

common
normal open
normal closed

external LED failure

external LED bulk

external LED 20-40%

external LED absorption

external LED 60-80%

external LED float

6 pole telephone jack
RJ 45

charger

NC          NO

C

DC+CSI

alarm contact

Summary of Contents for IVO SMART 12/30-2

Page 1: ...al information 2 2 Safety guidelines measures 2 3 Technical data 3 4 Technology 3 5 Installation 4 6 Operation 6 7 Batteries 6 8 Trouble shooting 7 9 Maintenance 8 10 EC declaration of conformity 8 11...

Page 2: ...d against rain moist dust and not condensing circumstances Never use the battery charger at locations where there is danger of gas or dust explo sion Use other than as mentioned under 2 is not conside...

Page 3: ...battery charger rectifier developed and produced by Mastervolt Amsterdam The IVO series goes with a family of advanced quality battery chargers Mastervolt distribu tes these products worldwide The bat...

Page 4: ...e char ger automatically switches back to a lower output voltage of 13 25V This voltage is sufficient to maintain the battery at a 100 charge During this phase the charge voltage can be entirely used...

Page 5: ...rging current for the cranking battery is 3A The char ging current for the main battery will in this case be 3A less Connect the minus of the cranking battery to the minus of the main battery Connect...

Page 6: ...and the charger starts immediately Turning off The IVO charger will be switched off by unplugging this power cord INDICATOR LEDS FLOAT The battery charger is in a trickle charge mode batteries are 10...

Page 7: ...aximum charge current will be reduced automatically Mains too low When the mains voltage is less than 105V the charger will regulate the current down Batteries not fully charged Charge current too low...

Page 8: ...RVOLT Address Snijdersbergweg 93 1105 AN AMSTERDAM The Netherlands Herewith declares that Product IVO battery charger Model IVO Smart 12 30 2 117V IVO Smart 12 50 2 117V Is in conformity with the prov...

Page 9: ...ERVOLT Snijdersbergweg 93 1105 AN Amsterdam The Netherlands Tel 31 20 3422100 Fax 31 20 6971006 APPENDIX A B V2 0 March 2004 IVO SMART 12 30 2 12 50 2 117 Volt battery charger export models U S A vers...

Page 10: ...10 IVO Smart Appendix A...

Page 11: ...factor 1 power factor controlled Max input power 540 Watt Efficiency 81 Output voltage nominal 12V DC Output current nominal 30 Amps Charge characteristic three step fully automatic IUoUo programmable...

Page 12: ...25 Iout 30 Amps at 77 F Tamb 25 C ELECTRO MAGNETIC COMPATBILITY Electro Magnetic Emission better than EN 50081 1 gen emmission standard scope residiential commercial light industry Electro Magnetic I...

Page 13: ...blocks OPERATING PRINCIPLE Fully automatic power factor corrected switch mode battery charger suitable as power supply using a separate non isolated pre regulator boost converter for power factor cor...

Page 14: ...nd under 20 C 24 Volt 60 mV C 5 0 mV C Uref 25 C f o r c e d f l o a t g e l w e t b a t t e r y d i o d e c o m p e n s a t i o n standard IUoUo characteristic IUoUo char increased with 0 6V IUoUo ch...

Page 15: ...actor 1 power factor controlled Max input power 850 Watt Efficiency 81 Output voltage nominal 12V DC Output current nominal 50 Amps Charge characteristic three step fully automatic IUoUo programmable...

Page 16: ...25 Iout 50 Amps at 77 F Tamb 25 C ELECTRO MAGNETIC COMPATBILITY Electro Magnetic Emission better than EN 50081 1 gen emmission standard scope residiential commercial light industry Electro Magnetic I...

Page 17: ...nstallation blocks OPERATING PRINCIPLE Fully automatic power factor corrected switch mode battery charger suitable as power supply using a separate non isolated pre regulator boost converter for power...

Page 18: ...and under 20 C 24 Volt 60 mV C 5 0 mV C Uref 25 C f o r c e d f l o a t g e l w e t b a t t e r y d i o d e c o m p e n s a t i o n standard IUoUo characteristic IUoUo char increased with 0 6V IUoUo c...

Page 19: ...set points can be adjusted in the charger by use of the adjustment interface The standard remote panel Specifications Remote cable Connector RJ45 6 pole male Max length 6 meter max Type twisted wire...

Page 20: ...ilure The DC alarm set points can be adjusted in the chargers by use of the adjustment interface The basic remote panel Specifications Remote cable Connector RJ45 6 pole male Max length 6 meter max Ty...

Page 21: ...ndard remote analogue jack smart basic remote panel temp sensor RS 232 forced to float gel wet type diode compensation 0 6V jumper selection main output 1 common min AC in start service service 1 Slav...

Page 22: ...lure Inverter Control on failure float bulk absorption Charger Control Charger Output current control on failure float bulk absorption Charger Control on bulk charge failure float absorption Charger C...

Page 23: ......

Page 24: ...MASTERVOLT Snijdersbergweg 93 1105 AN Amsterdam The Netherlands Tel 31 20 3422100 Fax 31 20 6971006...

Reviews: