20
Appendix B
CAUTION
These products fully comply to the latest CE
norms in force from Januari 1st 1996 and are
produced to ISO 9001 standards.
ISO 9001
1. Lethal voltages exist on your vessel. Make sure all shore power, onboard
generating sources and batteries are disconnected before beginning
installation of your electrical panel.
2. AC modules will have lethal voltages on the bus bars and terminals. The
coating on these bars is for identification only and should not be relied on
as a insulator.
Additional safety enclosures may be required in some installations.
3. Make sure all AC modules are bonded to the shipís AC ground bus. When
grouping modules together to form your panel, a single ground may be used.
Use a resistance meter to verify ground to all modules.
The basic remote panel is a useful power device for remote
control of the Mass an Ivo smart Mastervolt battery chargers.
The basic remote control does indicate the status of the charge
control by six high power leds.
The remote control is easy to install by a plug-in standard
twisted six pole RJ45 telephone plug between the analog
output of the charger and the panel. The communication of the
remote control and charger is based on analog technology.
The remote panel can be used as an interface for a custom
made panel or for a dual remote indicator.
The basic remote panel has a combined CSI-DC/alarm
(csi=charger status interface).
The potential free change-over contacts indicate if the
charger is ON or in general failure. The DC alarm set
points can be adjusted in the chargers by use of the
adjustment interface.
The basic remote panel
Specifications
Remote cable:
Connector RJ45, 6 pole, male
Max length 6 meter, max
Type twisted wire
External led drive:
Imax 5 mA
Umax 2,5V
General CSI alarm
Max rating 1 Amp, 30 VDC
NC-on When the charger is off or the charger is in
failure, the normally closed contact is closed
C Common
NO-on When the charger is on and no-failure is
indicated the normally open contact is closed
Connectors 0,75 mm2
MASTERVISION MODULAR SWITCHBOARDS
panel code
part number
C-4-RB
07-04-04100
DC low on 10.0 20.0 VDC
DC low off 11.0 22.0 VDC
DC high on 16.0 32.0 VDC
Delay time 30 30 SEC
12V 24V
DC high off 15.0 30.0 VDC
Combined CSI failure and DC high/low alarm
Bat TC failure Battery temperature sensor out of range <20
°
C & >60
°
C
Voltage sense failure Voltage sense out of range >3 VDC
Sys. temp. failure Charger is out of temperature range ìoverloadî (>75--85 C)
Short break indicator Charger in reduced current mode (short break mode) Uout <4..5VDC
DC alarm Battery range out of range (with standard setting of charger)
on
failure
Inverter Control
on
failure
float
bulk
absorption
Charger Control
Charger Output
current control
on
failure
float
bulk
absorption
Charger Control
on - bulk charge
failure
float
absorption
Charger Control
for Mass & IVO smart chargers
60 x 65 mm
40 mm
description:
type:
dimensions panel (wxh):
panel depth:
SPECIFICATIONS
remote basic charger control
common
normal open
normal closed
external LED failure
external LED bulk
external LED 20-40%
external LED absorption
external LED 60-80%
external LED float
6 pole telephone jack
RJ 45
charger
NC NO
C
DC+CSI
alarm contact