Mastervolt IVO SMART 12/30-2 User Manual Download Page 1

MASTERVOLT
Snijdersbergweg 93, 1105 AN  Amsterdam, The Netherlands
Tel. +31-20-3422100 / Fax +31-20-6971006

USERS MANUAL

V2.0 March 2004

1

General information  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2

Safety guidelines & measures  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

3

Technical data  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

4

Technology  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

5

Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

6

Operation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

7

Batteries  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

8

Trouble shooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

9

Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

10

EC declaration of conformity  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

11

Data sheets  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Appendix A

12

Installation sheet  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Appendix B

IVO SMART 12/30-2 & 12/50-2

117 Volt battery charger

-export models / U.S.A. version-

Summary of Contents for IVO SMART 12/30-2

Page 1: ...al information 2 2 Safety guidelines measures 2 3 Technical data 3 4 Technology 3 5 Installation 4 6 Operation 6 7 Batteries 6 8 Trouble shooting 7 9 Maintenance 8 10 EC declaration of conformity 8 11...

Page 2: ...d against rain moist dust and not condensing circumstances Never use the battery charger at locations where there is danger of gas or dust explo sion Use other than as mentioned under 2 is not conside...

Page 3: ...battery charger rectifier developed and produced by Mastervolt Amsterdam The IVO series goes with a family of advanced quality battery chargers Mastervolt distribu tes these products worldwide The bat...

Page 4: ...e char ger automatically switches back to a lower output voltage of 13 25V This voltage is sufficient to maintain the battery at a 100 charge During this phase the charge voltage can be entirely used...

Page 5: ...rging current for the cranking battery is 3A The char ging current for the main battery will in this case be 3A less Connect the minus of the cranking battery to the minus of the main battery Connect...

Page 6: ...and the charger starts immediately Turning off The IVO charger will be switched off by unplugging this power cord INDICATOR LEDS FLOAT The battery charger is in a trickle charge mode batteries are 10...

Page 7: ...aximum charge current will be reduced automatically Mains too low When the mains voltage is less than 105V the charger will regulate the current down Batteries not fully charged Charge current too low...

Page 8: ...RVOLT Address Snijdersbergweg 93 1105 AN AMSTERDAM The Netherlands Herewith declares that Product IVO battery charger Model IVO Smart 12 30 2 117V IVO Smart 12 50 2 117V Is in conformity with the prov...

Page 9: ...ERVOLT Snijdersbergweg 93 1105 AN Amsterdam The Netherlands Tel 31 20 3422100 Fax 31 20 6971006 APPENDIX A B V2 0 March 2004 IVO SMART 12 30 2 12 50 2 117 Volt battery charger export models U S A vers...

Page 10: ...10 IVO Smart Appendix A...

Page 11: ...factor 1 power factor controlled Max input power 540 Watt Efficiency 81 Output voltage nominal 12V DC Output current nominal 30 Amps Charge characteristic three step fully automatic IUoUo programmable...

Page 12: ...25 Iout 30 Amps at 77 F Tamb 25 C ELECTRO MAGNETIC COMPATBILITY Electro Magnetic Emission better than EN 50081 1 gen emmission standard scope residiential commercial light industry Electro Magnetic I...

Page 13: ...blocks OPERATING PRINCIPLE Fully automatic power factor corrected switch mode battery charger suitable as power supply using a separate non isolated pre regulator boost converter for power factor cor...

Page 14: ...nd under 20 C 24 Volt 60 mV C 5 0 mV C Uref 25 C f o r c e d f l o a t g e l w e t b a t t e r y d i o d e c o m p e n s a t i o n standard IUoUo characteristic IUoUo char increased with 0 6V IUoUo ch...

Page 15: ...actor 1 power factor controlled Max input power 850 Watt Efficiency 81 Output voltage nominal 12V DC Output current nominal 50 Amps Charge characteristic three step fully automatic IUoUo programmable...

Page 16: ...25 Iout 50 Amps at 77 F Tamb 25 C ELECTRO MAGNETIC COMPATBILITY Electro Magnetic Emission better than EN 50081 1 gen emmission standard scope residiential commercial light industry Electro Magnetic I...

Page 17: ...nstallation blocks OPERATING PRINCIPLE Fully automatic power factor corrected switch mode battery charger suitable as power supply using a separate non isolated pre regulator boost converter for power...

Page 18: ...and under 20 C 24 Volt 60 mV C 5 0 mV C Uref 25 C f o r c e d f l o a t g e l w e t b a t t e r y d i o d e c o m p e n s a t i o n standard IUoUo characteristic IUoUo char increased with 0 6V IUoUo c...

Page 19: ...set points can be adjusted in the charger by use of the adjustment interface The standard remote panel Specifications Remote cable Connector RJ45 6 pole male Max length 6 meter max Type twisted wire...

Page 20: ...ilure The DC alarm set points can be adjusted in the chargers by use of the adjustment interface The basic remote panel Specifications Remote cable Connector RJ45 6 pole male Max length 6 meter max Ty...

Page 21: ...ndard remote analogue jack smart basic remote panel temp sensor RS 232 forced to float gel wet type diode compensation 0 6V jumper selection main output 1 common min AC in start service service 1 Slav...

Page 22: ...lure Inverter Control on failure float bulk absorption Charger Control Charger Output current control on failure float bulk absorption Charger Control on bulk charge failure float absorption Charger C...

Page 23: ......

Page 24: ...MASTERVOLT Snijdersbergweg 93 1105 AN Amsterdam The Netherlands Tel 31 20 3422100 Fax 31 20 6971006...

Reviews: