PROBLEM:
Extractor does not run, no power.
Possible Cause
Possible Solution
1)
Fuse blown or circuit breaker tripped.
1)
Replace fuse with same rating or reset
circuit breaker.
2)
Faulty ON/OFF switches.
2)
Replace switch or switches.
3)
Loose wiring.
3)
Trace and repair.
4)
Faulty motor.
4)
Replace motor.
5)
Defective power cord or damaged plug.
5)
Replace power cord or plug.
6)
No power to pump.
6)
Check electrical system.
7)
Defective switch.
7)
Replace rocker switch
PROBLEM:
Loss of vacuum.
Possible Cause
Possible Solution
1)
Drain valve open.
1)
Close drain valve.
2)
Leaking around recovery lid.
2)
Replace recovery lid gasket.
3)
Holes in vacuum hose or loose cuffs.
3)
Replace hose or tighten cuffs.
4)
Defective vacuum motor.
4)
Repair or replace vacuum motor.
5)
Wand head or vacuum hose clogged.
5)
Check and unclog
6)
Water coming out of vacuum exhaust.
6)
Use a low foaming detergent.
7)
Recovery tank full.
7)
Drain dirty water out of recovery tank.
8)
Lint accumulation on vacuum filter screen.
8)
Clean filter screen. Replace if necessary.
PROBLEM:
Streaking, uneven spray, or no spray from jets.
Possible Cause
Possible Solution
1)
Spray jets clogged.
1)
Unclog jets.
2)
Worn spray jets.
2)
Replace spray jets.
3)
Faulty pump.
3)
Replace pump.
4)
Solution tank empty.
4)
Flush out tank and refill.
PROBLEM:
Pump not running properly
Possible Cause
Possible Solution
1)
Pump is pulsating.
1)
Check for clogged jets and clean.
2)
Loose or kinked hose.
2)
Check and replace hose if necessary.