![MasterCraft X-405 Operation & Maintenance Manual Download Page 5](http://html1.mh-extra.com/html/mastercraft/x-405/x-405_operation-and-maintenance-manual_1738365005.webp)
1]
Position extractor where you are going
to start cleaning.
2)
Switch
ON
the vacuum
and pump green switches
located on the front of the
extractor.
To start cleaning:
3)
Position the wand at a comfortable
position in front of you.
4)
Squeeze the carpet tool trigger while
slowly pulling it towards you. Apply a slight
downward pressure on the wand grip to
maximize extraction.
5)
Hold nozzle steadily against the carpet,
spraying solution and recovering the dirty
solution immediately.
4]
Before completing each path, shut
OFF
the solution supply and vacuum up the last
of the solution sprayed on. This will also
reduce the drying time of the carpet.
5]
The next cleaning path should overlap
the previous on by 2
1
/
2
" to 3
1
/
2
".
6]
When the width of the spray pattern
starts getting smaller, the solution tanks
need to be refilled. Turn
OFF
vacuum and
pump switches.
7)
Empty the dirty solution from the recov-
ery tank into a bucket by pulling
UP
on the
drain valve handle. Make sure to close the
valve after draining the tank.
When job is completed:
6)
Vacuum out the remaining cleaning
solution into the recovery tank.
7)
Empty the recovery tank and rinse out
dirt and debris from the tank.
Heavily Soiled Carpet:
Repeat the cleaning process a second
time, where possible in a crosswise direc-
tion. Allow the carpet to totally dry before
starting the second cleaning.
Confined Areas:
Use the upholstery tool to clean stairs,
upholstery, in corners, under obstacles
and edges, etc.
O
PERATING
I
NSTRUCTIONS
P
AGE
5
S
ET
-U
P
&
O
PERATING
P
ROCEDURES
Attach Cleaning Tool:
1)
Connect vacuum hose to the vacuum
intake and the extraction wand.
2)
Connect the solution hose to the unit
and the wand. Pull the sleeve on the cou-
pler and insert the male quick disconnect
plug on the hose. The sleeve should
'CLICK'
and retract back indicating a posi-
tive seal.
Filling Solution Tank:
1)
Fill solution tank with hot tap water (not
to exceed 140° F).
2)
Pour cleaning solution in tank following
the directions on the bottle’s label for best
results.
It is recommended that you use a low
foaming chemical or a defoamer to elimi-
nate foam build-up in the recovery tank and
damage to the vacuum motor. If moisture
does enter the vacuum motor it is neces-
sary to use WD-40 on the motor.
Electrical:
Plug extractor into a dedicated 120 volt,
15 AMP circuit. Never remove ground
prong from the plug.
If circuit breaker trips during operation:
A)
Turn
OFF
the extractor.
B)
Reset the breaker.
C)
Plug electrical cord into a different
outlet and resume cleaning.