MasterCraft 62-3510-0 Owner'S Manual Download Page 4

Installation

4

If your basement has water or
moisture on floor, do not walk on

wet area until all power has been turned off. If
shut-off box is in basement, call electric company
to shut-off service to house, or call local fire
department for instructions. Remove pump and
repair or replace. Failure to follow this warning
can result in fatal electrical shock.

Do not use in hazardous or
explosive locations.

INSTALLATION

1.

This unit can be installed in sump pit with min-
imum diameter of 12" (30cm) and depth of 12"
(30cm). Sump pit may be constructed of tile,
concrete, steel or plastic. Check local codes for
approved materials.

2.

Install pump on solid, level foundation, as near
as possible to center of sump pit. Do not hang
pump from discharge pipe or power cord.

Pump must be level (column
must be vertical) when oper-

ating.

If motor is tilted, internal start/run switch

may overheat and damage motor.

3.

Pump should not be installed on clay, earth or
sand surfaces. Clean sump pit of small stones
and gravel which could clog the pump. Keep
pump inlet screen clear.

4.

Thread discharge pipe into pump body careful-
ly to avoid stripping or crossing threads.

NOTICE: 

Do not use ordinary pipe joint com-

pound on plastic pipe or pump. Pipe joint com-
pound can attack plastics and damage pump.

5.

To reduce motor noise and vibrations, a short
length of rubber hose (1-5/8" (41mm) I.D., e.g.
radiator hose) can be connected into discharge
line near pump using suitable clamps.

Risk of electric shock. Pump
is designed for 115V., 60 HZ

operation and requires an individual branch cir-
cuit of 15 amperes capacity. It is supplied with
a 3-wire cord set with grounding-type plug for
use in a 3-wire, grounded outlet. Do not cut off
the round grounding prong. For safety, outlet
must always be electrically grounded to a suit-
able electrical ground such as a grounded water
pipe or a properly grounded metallic raceway
or ground wire system.

6.

Locate Float Rod Guide (Key No. 6) about 6"
(16cm) below motor. Clamp guide to column
with screw provided.

Risk of flooding.

Be sure that

guide is securely clamped so

that float rod is vertical and can move up and
down freely. If float is angled or binds, pump
may not start, allowing flooding to occur.

7.

Screw float onto threaded end of rod. Threads
on rod will cut threads into corrosion resistant
float.

8.

Insert plain end of float rod up through eye of
rod guide.

9.

Slide one rod stop on float rod before passing
rod through eye of pump switch. Slide 2nd rod
stop on rod after passing through eye of switch.
Position 2nd rod stop flush with top of rod.

10. Position lower rod stop to within 8"(20cm) of

switch lever arm. With lower rod stop in this
position, pump will automatically cycle at
approximately 2-1/2" (6cm) off and 10-12" 
(25-30cm) on. For faster cycling, move lower
rod stop closer to switch lever arm.

11. If pump discharge line is exposed to outside

subfreezing atmosphere, then portion of line
exposed must be installed so any water remain-
ing in pipe will drain to outfall by gravity.
Failure to do this can cause water trapped in
discharge to freeze which could result in dam-
age to pump.

12. Install an in-line check valve to prevent flow

backwards through pump after pump shuts off.

NOTICE: 

The check valve should be equipped

with an air bleed hole to prevent airlocking the
pump. If using a check valve without an air
bleed hole, drill a 1/8" (3.2mm) hole in dis-
charge pipe just above pump body but below
the check valve to prevent air locks.

13. After all piping and controls have been

installed, unit is ready for operation.

14. Run pump through one cycle to check float

switch operation.

The pump motor is equipped

with automatic resetting

thermal protector and may restart unexpected-
ly. Protector tripping is an indication of motor
overloading as a result of operating pump at
low heads (low discharge restriction), exces-
sively high or low voltage, inadequate wiring,
incorrect motor connections, or a defective
motor.

Discharge

About 6"

About 8"

Check 
Valve
(Purchase
Separately)

Summary of Contents for 62-3510-0

Page 1: ...Installation Operation Parts For further operating installation or maintenance assistance CONSUMER HOTLINE 1 877 455 5508 CTC842 8 27 09 MD OWNER S MANUAL Pedestal Sump Pump 62 3510 0 ...

Page 2: ...carry a contamination hazard with them If your sewage pump has failed Wear rubber gloves when handling the pump For warranty purposes return the pump s cord tag and original receipt of purchase to the retail store Dispose of the pump according to local disposal ordinances Exceptions to the Twelve 12 Month Limited Warranty Product Warranty Period 62 3518 4 62 3522 2 62 3523 0 62 3558 8 62 3569 2 2 ...

Page 3: ... cannot move around in sump 5 Secure discharge line before starting pump An unsecured discharge line will whip possibly causing personal injury and or property dam age 6 Check hoses for weak or worn condition before each use making certain all connections are secure 7 Inspect sump pump and system components monthly Keep free of debris and foreign objects Perform routine maintenance as required FIR...

Page 4: ...nd wire system 6 Locate Float Rod Guide Key No 6 about 6 16cm below motor Clamp guide to column with screw provided Risk of flooding Be sure that guide is securely clamped so that float rod is vertical and can move up and down freely If float is angled or binds pump may not start allowing flooding to occur 7 Screw float onto threaded end of rod Threads on rod will cut threads into corrosion resist...

Page 5: ...oper positioning of Lower float rod stop stops too often float rod stop Faulty automatic switch Replace automatic switch Pump is noisy Improper installation Refer to No 5 in Installation Instructions Noisy motor Replace pump Pump will not Debris around float or Remove debris from sump Check to see float is stop running float rod stuck not rubbing sump wall or float rod rubbing or stuck against sum...

Page 6: ...Pump Body 1 S1 31B 3 Impeller 1 PS5 21P 4 Base Plate 1 PS4 17P 5 Float 1 FT0013 63 6 Float Rod Guide 1 RP0005249 7 Float Rod 1 RP005168S 8 Switch 1 9 Float Stop 2 RP0005248 Model 62 3510 0 If the motor fails replace the entire pump Select switch model number below Switch FP0020 Switch FP0018 7D ...

Page 7: ...D GUIDE D UTILISATION Pompe d assèchement sur pied 62 3510 0 Installation fonctionnement pièces Pour plus de renseignements concernant l utilisation l installation ou l entretien ASSISTANCE TÉLÉPHONIQUE 1 877 455 5508 ...

Page 8: ... cas de défaillance de la pompe d eaux d égout Porter des gants en caoutchouc pour manipuler la pompe À des fins de garantie retourner l étiquette figurant sur le cordon de la pompe et l original du reçu au détaillant Mettre la pompe au rebut conformément à la réglementation locale Exceptions à la garantie limitée de douze 12 mois Produit Période de garantie 62 3518 4 62 3522 2 62 3523 0 62 3558 8...

Page 9: ...he Si à la suite de cela l interrup teur vient heurter le côté du puisard il se peut que l inter rupteur y adhère et empêche la mise en marche de la pompe Assurez vous de bien caler la pompe pour qu elle ne se déplace pas dans le puisard 5 Caler la canalisation de refoulement avant de démarrer la pompe Une canalisation non calée peut donner des coups de fouet qui risquent de provoquer des blessure...

Page 10: ... Risques de débordement Le guide doit être correctement fixé pour que la tige du flotteur soit en position verticale et puisse monter et descendre librement Si le flotteur est incliné ou bloqué la pompe risque de ne pas démarrer ce qui peut provoquer un débordement 7 Viser le flotteur sur l extrémité filetée de la tige Le file tage de la tige taraudera un trou dans le flotteur résis tant à la corr...

Page 11: ...position de Baisser l arrêt de la tige du flotteur démarre et l arrêt de la tige du s arrête trop flotteur souvent Interrupteur automatique Remplacer l interrupteur automatique défectueux La pompe Mauvaise installation Se reporter au N 5 des instructions d installation fait du bruit Moteur bruyant Remplacer la pompe La pompe Débris autour du flotteur Retirer les débris du puisard Vérifier si le fl...

Page 12: ... 21P 4 Plaque du socle 1 PS4 17P 5 Flotteur 1 FT0013 63 6 Guide de la tige du flotteur 1 RP0005249 7 Tige du flotteur 1 RP005168S 8 Interrupteur 1 9 Butée du flotteur 2 RP0005248 Modèle 62 3510 0 Si le moteur tombe en panne remplacer la pompe Choisir le modèle d interrupteur en se reportant ci dessous Interrupteur FP0020 Interrupteur FP0018 7D ...