![MasterCraft 2007 MariStar Owner'S Manual Download Page 25](http://html1.mh-extra.com/html/mastercraft/2007-maristar/2007-maristar_owners-manual_1738296025.webp)
2007 MasterCraft Owners Manual - Page 5-4
a slide that fi ts over the switch. Be sure that the slide is fi rmly attached to the switch before
starting.
The switch is located near the throttle control box. If the slide is left off or loose, the en-
gine will crank but will not start.
The safety switch lanyard must be attached to the operator whenever the engine is start-
ed. Failure to do so may result in serious injury or death.
Blower Switch
A two-position rocker switch activates the engine box ventilation blower. Push the top half of the switch to turn the
blower ON.
Note: The blower must operate for a minimum of four (4) minutes before starting the engine at any time. The blower
must also be operated during idle and slow-speed running, but is not necessary at cruising speed.
Failure to operate the blower as instructed could cause improper ventilation of the boat engine and bilge areas. Fuel
vapors can accumulate in this area and cause a fire or explosion which may result in serious injury or death!
The main breaker panel is shown above and is located under the dash panel. The
waterproof fuse shown below left is for the stereo amplifi er, and the additional
accessory breaker shown below right is located near the battery box.
Manual and Automatic
Bilge Pump Switch
A three-position rocker switch activates the bilge pump. Push
the top half of the switch to turn the bilge pump to the manual
ON position. Press the switch down to activate the bilge pump for
automatic mode while the boat is underway. When the switch is
centered, the bilge pump is OFF. The bilge pumps on all V-drive
models will be in the automatic mode when the ignition key is
turned ON.
On boat models equipped with a ballast system, a three-posi-
tion switch will allow for the fi lling or emptying of the ballast tanks
and/or bags. It is important to be aware that the engine must
operate at 1500 RPM during the fi ll and empty processes. Failure
to do so can result in malfunction or permanent damage to the
ballast pumps that force the water through the system. This is not
covered under warranty.
Circuit Breakers
All major boat circuits are protected from shorting and over-
load by re-settable circuit breakers. If a problem develops with
one of the following circuits, switch OFF the circuit and wait
about one minute. Then push the appropriate breaker button ful-
ly and switch ON the circuit. If the circuit continues to trip, there
is a problem somewhere that must be attended to immediately.
See your MasterCraft dealer.
The location of the main circuit breaker board is under the
dash panel. In some models, there is an additional breaker pan-
el to assist with the accessory load, and it is located near the
Summary of Contents for 2007 MariStar
Page 1: ......