headline bars
continuation tabs
notes
warnings
model no. 062-3593-2 | contact us 1-800-689-9928
18
TROUBLESHOOTING
Problem
Possible Causes
Solutions
Motor will not run.
Fuse is blown or circuit breaker
tripped.
Power cord not plugged in.
DISCONNECT POWER. Replace fuse or reset
circuit breaker.
Plug into 115 V grounded outlet.
Motor runs hot and
overload kicks off or
motor does not run
and only hums.
Voltage is too low.
Impeller not moving freely.
Check voltage being supplied to pump.
Check that impeller moves freely and is not
clogged.
Motor runs but no
water is delivered.
(Unplug pump, then
open faucets and see
if water is flowing
through system.)
Improper priming.
Clogged water filter.
Discharge valve closed.
Pipe size too small.
Impeller is plugged.
Pipes are frozen.
Re-prime according to instructions.
Stop pump, shut off water, and change
filter cartridge. Filter should be installed on
discharge side of pump.
Open valve.
Re-pipe using pipe of the same size as
suction and discharge ports on pump.
Clean impeller.
Thaw pipes.
Pump does not deliver
water to full capacity.
Corroded pipes.
Piping is too small in size.
Pump not being supplied with
enough water.
Low voltage.
Replace with plastic or new steel pipe.
Re-pipe using pipe the same size as suction
and discharge ports on pump.
Enlarge inlet pipe; check well pump system.
Make sure outlet voltage is at 115 V.
TROUBLESHOO
TING