model no. 062-3424-6
INSTRUCTION
MANUAL
IMPORTANT:
Please read this manual carefully before runningthis pump and save it for reference.
Stainless Steel
IRRIGATION JET PUMP
Page 1: ...model no 062 3424 6 INSTRUCTION MANUAL IMPORTANT Please read this manual carefully before running this pump and save it for reference Stainless Steel IRRIGATION JET PUMP ...
Page 2: ...model no 062 3424 6 contact us 1 800 689 9928 2 ...
Page 3: ...4 Warranty 15 TABLE OF CONTENTS TABLE OF CONTENTS NOTE If any parts are missing or damaged or if you have any questions please call our toll free helpline at 1 800 689 9928 SAVE THESE INSTRUCTIONS This manual contains important safety and operating instructions Read all instructions and follow them with use of this product ...
Page 4: ... Amps Max Head Max Flow Discharge Size Power Cord Length 062 3424 6 115 V 60 Hz 3 4 HP 6 5 A 108 32 9 m 800 U S GPH 3028 L h 1 2 5 cm 7 2 13 m TECHNICAL SPECIFICATIONS 20 6 1 m 60 18 3 m 90 27 4 m 100 30 5 m 800 GPH 3028 L h 470 GPH 1779 L h 300 GPH 1136 L h 190 GPH 719 L h Max Head 108 32 9 m PERFORMANCE ...
Page 5: ...disassembling may cause dangerous electrical wiring issues CAUTION This pump is made of high strength corrosion resistant materials It will provide trouble free service for many years when properly installed maintained and used However inadequate electrical power or blockage by dirt could cause damage to the pump and void the warranty To minimize the potential for water damage due to pump failure ...
Page 6: ...r the connection ends fall into water If using a 50 15 2 m cord use 16 gauge wire If using 100 30 5 m cord use 14 gauge wire 10 Make certain the electrical circuit to the pump is protected by a 10 A or larger fuse or circuit breaker 11 Periodically inspect pump and system components to ensure that the pump inlets are free of mud sand and debris DISCONNECT THE PUMP FROM THE POWER SUPPLY BEFORE INSP...
Page 7: ...rranty AII connections must be air tight A single leak will prevent proper operation of the pump and may cause the pump to run dry If the pump runs dry this will void the warranty NOTE If standard garden hose is used for suction line the hose could collapse allowing the pump to run dry This could cause permanent damage and void warranty This pump is not intended for permanent installation or long ...
Page 8: ... sold separately as the discharge line INSTALLATION INSTRUCTIONS a Wrap threads of discharge tee sold separately with thread tape b Thread a 1 2 5 cm discharge tee 2 into the outlet of the pump c Thread hose adaptors B into pump outlet and into the discharge tee 2 Positioning the Pump NOTE The inlet line may be PVC or reinforced hose Small leaks in the suction line greatly reduce the efficiency of...
Page 9: ...of system purchase a higher capacity law or irrigation pump Installing the Pump 3 4 a Connect a 3 4 1 9 cm heavy duty garden hose sold separately to the pump inlet 1 The inlet connection can also be used with 1 2 5 cm PVC pipe Note If you are using a PVC pipe you will need a 1 2 5 cm male NPT X slip adaptor b Connect an outlet pipe or 3 4 1 9 cm standard garden hose sold separately to the discharg...
Page 10: ...rder to monitor pressure Priming the Pump Running the Pump 1 2 DANGER Risk of electric shock Always disconnect the electrical supply before attempting to install service or perform any maintenance If the power source is out of sight lock and tag in the open OFF position to prevent unexpected power application Failure to do so could result in fatal electric shock Only qualified electricians should r...
Page 11: ...h pressure hoses or pipes for the outlet connection or pipes for the inlet suction connection Never remove the ground prong on the power cord Never hardwire the power cord Cutting the cord hardwiring or removing the ground prong can result in death or serious injury and will void the warranty 2 3 1 A a Disconnect the suction 1 and discharge 2 lines from the pump A b Remove the water drain plug 3 f...
Page 12: ... no 062 3424 6 contact us 1 800 689 9928 12 PARTS LIST PARTS LIST 9 10 11 12 17 18 19 20 21 22 13 14 15 16 6 1 3 4 5 8 7 2 24 25 26 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 27 28 29 30 31 32 23 ...
Page 13: ...Mechanical seal Support cover Waterproof ring Motor flange Circlip for shaft Circlip for shaft Shaft key No Qty Description 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 1 1 3 0 12 1 2 1 4 1 1 1 1 1 1 1 1 1 4 1 1 1 1 1 0 18 0 02 Rotor Stator Connecting terminal Line Capacitor Screw Cord clip Screw Terminal box Sealing ring Sealing washer Terminal nut Cable Fan cover Fan...
Page 14: ...r use a shorter extension cord 3 Remove the blockage 4 Contact customer service at 1 800 689 9928 1 Repair or replace the suction line 2 Remove the blockage 3 Replace the seal 4 Lower the pump 5 Straighten the hose 6 Tighten the fittings 7 Submerge the suction hose end 8 Clean the inlet Problem Possible Cause Corrective Action 1 The piping or hose is fouled or damaged 2 The voltage is low 3 The ho...
Page 15: ...WARRANTY AND CAUSE DAMAGE OR PERSONAL INJURY This Mastercraft product carries a three 3 year LIMITED warranty against defects in workmanship and materials This product is not guaranteed against wear or breakage due to misuse and or abuse Made in China Imported by Mastercraft Canada Toronto Canada M4S 2B8 ...