PRESSURE SWITCH INSTALLATION INSTRUCTIONS
To complete the installation, you must connect the power source to the pressure switch. The
pressure switch allows for automatic operation; the pump starts when pressure drops to the
“cut-in” setting (30 PSI pre-set).
To wire the pressure switch:
• Remove the pressure switch cover on
pump to expose the wiring terminals.
• Connect the green ground wire of the
power supply to the switch ground
terminal.
• Connect the power supply wires to the
two outside terminals marked “LINE”
and replace the switch cover.
If you had a different pressure switch on the old pump (e.g., 20/40 PSI), make sure to adjust the
pressure in your tank to 28 PSI. You may need an air compressor to add air pressure. If you have
too much air pressure in the tank, simply press the air stem down to release air.
You will need a tire gauge to test the pressure in the tank.
WARNING:
• Before wiring the pressure switch, turn off the power source to which you are connecting
to avoid potentially life-threatening electric shock.
• It is recommended all electrical work be performed by a licensed electrician.
• When wiring from the power source to the pressure switch, it is recommended that you
use either a 14-gauge or 12-gauge cord.
Note: The ground connection must be made at this terminal. The ground conductor must not be
smaller than the circuit conductors supplying the motor.