OPERA
TING INSTR
UCTIONS
17
8
U.S.
GALLONS (30.3 L) AIR COMPRESSOR 058
-
9316
-
0
5. Set the pressure switch (1) to the ON
position. The compressor will start. Run
the compressor for 30 minutes. If it fails,
turn it off immediately and call the tol
l-
free helpline at: 1
-
800
-
689
-
9928. Please
note that breaking
-
in the unit is only
required prior to first use
(fig I)
.
6. After 30 minutes, turn off the pressure
switch.
7. Close the tank drain valve (I) by turning
it clockwise
(fig J)
.
8. Set the pressure switch to the ON
position. The air receiver will fill to
cut
-
out pressure and then the
compressor’s motor will stop. The
compressor is now ready for use.
CAUTION!
Potential hazard that may result in moderate injury or damage to
equipment.
•
Use a dedicated circuit. The compressor will use the full capacity of a
typical 15 A household circuit. If any other electrical devices are drawing
from the compressor’s circuit, the air compressor may fail to start. Low
voltage or an overloaded circuit can result in sluggish starting that causes
the motor thermal overload protector or circuit breaker to trip, especially in
cold conditions.
•
Connect the power cord only after break
-
in process has been completed,
otherwise motor might get damaged.
MC-589316-17
1
fig I
MC-589316-18
1
fig J