MAINTENANCE
19
5 U.S. GALLONS (18.9 L)
•
135 PSI (MAX) AIR COMPRESSOR 058
-
9315
-
2
General maintenance
Draining the air tank
Through normal operation of your air compressor, condensation water will accumulate in the tank.
To prevent corrosion of the tank from the inside, condensation must be drained at the end of every
workday.
Note: Allow unit to cool before draining tank. Drain valve becomes hot during operation.
•
Set the pressure switch to the OFF position.
•
Unplug the power cord.
•
Turn air pressure regulator knob counter
-
clockwise to set the outlet pressure to zero.
•
Pull and hold ring on safety valve, allowing air to bleed from the tank until air pressure is
minimized.
•
Place suitable container under unit to catch water.
•
Slightly tilt unit and turn drain valve counter
-
clockwise to open.
•
After the water has been drained, close the drain valve (clockwise). The air compressor can
now be stored.
WARNING!
Potential hazard that could result in serious injury or loss of life.
•
If any of the following symptoms appear while operating the product, stop
using the product immediately, or serious personal injury could result. Only
an authorized service centre should perform repairs on this product.
•
Disconnect the electrical plug and disconnect any tools from air supply
before attempting any adjustment.
DESCRIPTION
COMPONENTS
MAXIMUM SERVICE INTERVAL
Daily
Weekly
Monthly
To drain moisture
Air tank
X
To check proper operation
Pressure relief valve
X
To clean
Air filter
X
Test for leaks
All connections
X