7

8

Air compressor 11-gAllon (41.6 l) - 058-8386-8

Air compressor 11-gAllon (41.6 l) - 058-8386-8

A. elecTric moTor:

 The motor is used to power the pump. it is equipped with at thermal overload 

protector. if the motor overheats for any reason, the thermal overload protector will shut it down in 
order to prevent the motor from being damaged.

B. Air compressor pUmp:

 The pump compresses the air and discharges it into the tank via the 

piston that moves up and down in the cylinder.

c. pressUre sWiTcH:

 This switch turns the compressor on and off. it is operated manually and 

when it is in the on position, it allows the motor to start if the pressure in the air tank is below the 
factory set cut-in pressure, and allows the motor to stop if the pressure in the air tank reaches the 
factory set cut-out pressure. Be sure to set this switch to the oFF position when the compressor is 
not being used and before unplugging the compressor.

D.  sAFeTY VAlVe:

 This valve is used to prevent system failure by draining pressure from the system 

when it reaches a preset level if the pressure switch has not shut down the motor. it will pop open 
automatically, or it can be activated manually by pulling the ring on the valve.

e. Air pressUre regUlATor:

 The regulator is used to adjust the pressure inside the line to the 

tool that is being used. Turn the knob clockwise to increase the pressure and counter-clockwise to 
decrease the pressure.

 

[  

WARNING!

 

Do not exceed the tool’s maximum working pressure.

F. TAnK pressUre gAUge: 

The gauge measures the pressure level of the air that is stored in the 

tank. it cannot be adjusted by the operator and it does not indicate the pressure inside the line.

g. oUTleT pressUre gAUge: 

The gauge measures the regulated outlet pressure.

H. Air oUTleT:

 The outlet is connected to the 1/4” (6.4 mm) npT air hose.

i. Air TAnK DrAin VAlVe:

 The drain valve is used to remove moisture from the air tank after the 

compressor is shut off.

 

[  

WARNING!

 

Do not attempt to open the drain valve when there is more than 

   

10 psi of air pressure in the tank.

Ke

pA

rT

s D

iA

gr

Am

Ke

pA

rT

lis

T

AIR TANk

DRAIN VALVE (I)

ELECTRIC 

MOTOR (A)

AIR  COM PRESSOR 

PUMP (B)

PRESSURE 

SWITCh (C)

AIR PRESSURE 

REGULATOR (E)

SAFETY 

VALVE (D)

OUTLET 

PRESSURE

GAUGE (G)

TANk

PRESSURE

GAUGE (F)

AIR 

OUTLET (h)

POWER 

CORD (k)

AIR

TANk (J)

058-8386-8-Mastercraft-11G-3HP-Air-Compressor-EN-08.indd   7-8

7/4/12   11:26 AM

Summary of Contents for 058-8386-8

Page 1: ...re using the product It contains important information for your safety as well as operating and maintenance advice Keep this instruction manual for future use Should this product be passed on to a thi...

Page 2: ...e motor might get damaged see Breaking in the pump page 14 STEP 4 Close the tank drain valve located on the bottom of the air tank TABLE OF CONTENTS QUICK START GUIDE TECHNICAL SPECIFICATIONS 3 SAFETY...

Page 3: ...rd that may result in moderate injury or damage to equipment IMPORTANT Installation operation or maintenance information that is important but not hazard related Safety Advice DANGER 1 RISK OF FIRE OR...

Page 4: ...the power cord from damage and puncture Inspect them for weak or worn spots every week and replace them if necessary 4 Always wear hearing protection when using an air compressor Failure to do so may...

Page 5: ...has not shut down the motor It will pop open automatically or it can be activated manually by pulling the ring on the valve E Air pressure regulator The regulator is used to adjust the pressure inside...

Page 6: ...gallon 41 6 L air compressor at a maximum of P 135 PSI The device has been designed constructed for household use only WARNING This air compressor is not designed for continuous operation or unlimite...

Page 7: ...r its intended use 3 Positioning of the air compressor a Position the air compressor near an electrical outlet b The compressor must be at least 12 31 cm from any wall or obstruction in a clean well v...

Page 8: ...not provided to the compressor s air outlet H Breaking in the pump 1 Set the pressure switch C to the OFF position OFF 2 Open the tank drain valve I by turning it counter clockwise to permit the air...

Page 9: ...he ON position The air receiver will fill to cut out pressure and then the compressor s motor will stop The compressor is now ready for use Before each start up 1 Set the pressure switch C to the OFF...

Page 10: ...ing of condensation water NOTE Refer to To drain tank page 19 Daily Check the valve Pull activate the safety valve daily to ensure that it is operating properly and to clear the valve of any possible...

Page 11: ...is in the OFF position Set the pressure switch to the ON position The extension cord is the wrong wire gauge or is too long Check Technical Specifications proper wire gauge and cord length The motor s...

Page 12: ...re is moisture in the discharge air There is condensation in the air tank caused by a high level of atmospheric humidity or because the air compressor has not been running long enough Drain the air ta...

Page 13: ...reof which is worn or broken or which has become inoperative due to abuse misuse accidental damage neglect or lack of proper installation operation or maintenance as outlined in the applicable owner s...

Page 14: ...al or exemplary damages arising in connection with the sale use or inability to use this product Notice to Consumer This warranty gives you specific legal rights and you may have other rights which ma...

Reviews: