MasterCool 43060-TB Instructions Download Page 4

4

7.  Remove the cap from the top of the flow meter.
8.  Turn the flow meter upside down to remove the ball.
9.  Clean the inside of the flow meter with Isopropyl alcohol and dry thoroughly.
10. Clean the ball with a dry cloth. 

NOTE:

 Do not use alcohol, cleanser or any detergent on the ball.

11. Assemble the flow meter in the reverser order.
12. Reinstall the flow meter into the machine in the reverse order. 

NOTE: 

The blue hose is attached to the top of the flow meter. The red hose is attached to the bottom of the flow meter. 

 

Draining the Smoke Hose:

1.  Disconnect the unit from the power supply.
2.  Disconnect the unit from external Air/Inert Gas source.
3.  Disconnect the smoke hose from the back of the machine.
4.  Hang the hose in a vertical position and place a container under the smoke hose.
5.  Allow the excess oil to drain out of the smoke hose.
6.  Reinstall the smoke hose.

TROUBLESHOOTING:

Problem

Solution

No Power Light

Ensure that the power is properly Connected

No Air Flow

•  Open the flow control valve
•  Check the air pump
•  Check that the hoses are not kinked or pushed into machine

Not Enough Smoke

•  Check the fluid level
•  Open the flow control valve clockwise
•  Check that the hoses are not kinked or pushed into machine
•  Check the smoke light, if light is off press the smoke button. If 

using the internal pump, ensure that the pump is turned on

•  Turn the unit off. Wait 10 -20 minutes then start again.

Poor Smoke Density or Volume

•  Insufficient smoke producing fluid: Refill
•  Flow control valve is partially closed
•  Smoke output hose is kinked

For parts or service contact the service department: 1-888-825-6989

43060-TB-INST

WARNING: 

Cancer and Reproductive Harm – www.P65Warnings.ca.gov

Summary of Contents for 43060-TB

Page 1: ...Source Max 28 psi 190 kPa Safety Pressure Relief 120 5 psi Oil Fill Line Indicator 3 4 oz 100 ml 10 ml Flow Meter 0 0 040 in 0 1 0 mm Power Consumption Max 6 5 Amps Operating Temperature 0 F to 140 F 17 C to 60 C Operating Humidity No Restrictions Operating Altitude No Restrictions Vapor Output Hose 10 feet Power Cable 10 feet Pressure Supply Air Inert gas Pump Dimensions 11 8 x 8 1 x 11 in 300 x ...

Page 2: ...s that could damage or puncture the bladder 1 Completely insert the bladder into the duct that is being tested so that both collars are inside of the duct 2 Close the pressure relief valve by turning the knob clockwise until it is tight 3 Compress and release the hand pump repeatedly until the bladder is secured inside the duct 4 Ensure that the bladder is secured by gently pulling on both hoses 5...

Page 3: ... SMOKE button 5 Use the flashlight to locate any leaks Note The air filter box may need to be sealed so that the circuit being tested does not back flow into the air filter box Note Some vacuum hoses may need to be capped to find small or to isolate leaks Note Some vacuum components may be not be 100 percent sealed by design 6 Repair and re test until no more leaks are found Exhaust Leaks 1 Insert...

Page 4: ...tion and place a container under the smoke hose 5 Allow the excess oil to drain out of the smoke hose 6 Reinstall the smoke hose TROUBLESHOOTING Problem Solution No Power Light Ensure that the power is properly Connected No Air Flow Open the flow control valve Check the air pump Check that the hoses are not kinked or pushed into machine Not Enough Smoke Check the fluid level Open the flow control ...

Reviews: