background image

4. PROGRAMMING MENU

Through the programming menu you can set some functions of the module.

4.1. Working time

The module provides the ability to program the working time (time needed to bring the motor from the lower end position to the upper end position). The factory sets the working time
of 130 sec. The working time can vary from a minimum of 1 sec to a maximum of 250 sec.

How to set the working time:

- Bring the motor in an intermediate position.
- Disconnect the power to the module and wait a few seconds. Connect the power to the module.

- Within 15 sec press briefly 5 times (less than 0.5 sec) in quick succession the

S button. The motor makes 3 upward movements.

- Press briefly

S. The motor performs a downward manoeuvre. Wait until the motor stops for the intervention of the previously set mechanical limit switch.

- Press briefly

S. The motor performs an upward manoeuvre. Wait until the motor stops for the intervention of the previously set mechanical limit switch.

- Press briefly

S. The module saves the working time and indicates the operation with an alternate movement of the motor (downwards and upwards).

4.2. Insertion delay on general command

The module is equipped with inputs for the general command. In the event that it is necessary to distribute the start of motors to avoid overloading the power line, you can use this function.
The general commands (upward or downward) will be performed from the module after the selected delay. The factory sets the "insertion delay on the general command" at value 1 (00
seconds = immediate start).

How to modify the insertion delay :

- Bring the motor in an intermediate position.
- Disconnect the power to the module and wait a few seconds. Connect the power to the module.

- Within 15 sec press briefly 5 times (less than 0.5 sec) in quick succession the

S button. The motor makes 3 upward movements.

-

S. The motor returns to its initial position and performs 4 upward movements.

Press briefly

-

S. The module performs a number of upward movements equal to the currently set value (see table).

Press briefly

- If you want to modify the setting, press briefly S a number of times equal to the desired value (see table).

- After approximately 8 seconds, the module displays the setting and return to normal activities.

4.3. «Air change» function

If the module is used for the movement of roller shutters, it can be useful to activate this function. Pressing briefly for 2 times (less than 0.5 sec) in quick succession button

S, the module

lowers the roller shutter and, at the end of working time, it commands a small upward movement, such as to permit ventilation.

Pressing briefly for 2 times (less than 0.5 sec) in quick succession the

G button the operation will affect all the roller shutters wired to the General button and will be followed in respect of

the insertion delay on the general command. The duration of short upward movement can be set according to the size of the roller shutter. The factory sets the function "air change" to the
value 1 (INACTIVE).

How to set the duration of the small upward movement:

- Bring the motor in an intermediate position.
- Disconnect the power to the module and wait a few seconds. Connect the power to the module.

- Within 15 sec press briefly 5 times (less than 0.5 sec) in quick succession the

S button. The motor makes 3 upward movements.

-

S. The motor returns to its initial position and performs 4 upward movements.

Press briefly

-

S. The motor returns to its initial position and performs 5 upward movements.

Press briefly

-

S. The module performs a number of upward movements equal to the currently set value (see table).

Press briefly

- If you want to modify the setting, press briefly S a number of times equal to the desired value (see table).

- After approximately 8 seconds, the module displays the setting and return to normal activities.

Movements

of the motor

«Air change»

function

1 movement

INACTIVE

2 movements

01 s

3 movements

02 s

4 movements

03 s

5 movements

04 s

6 movements

05 s

4.4. Selection of the operating logic of the buttons

- Bring the motor in an intermediate position.
- Disconnect the power to the module and wait a few seconds. Connect the power to the module.

- Within 15 sec press briefly 5 times (less than 0.5 sec) in quick succession the

S button. The motor makes 3 upward movements.

-

S. The motor returns to its initial position and performs 4 upward movements.

Press briefly

-

S. The motor returns to its initial position and performs 5 upward movements.

Press briefly

-

S. The motor returns to its initial position and performs 6 upward movements.

Press briefly

-

S. The module changes the setting and indicates the operation with an alternate movement of the motor (downwards and upwards).

Press briefly

5. RESET

- Disconnect the power to the module.
- Connect together the terminals 1, 5, 6 as in figure.
- Connect the power to the module. After about 30 s the motor performs two brief movements (alternate) to show the restoration of factory conditions.
- Disconnect the power to the module.
- Restore the connections and connect the power.

OFF

DISCONNECT

THE POWER

1

2

3

4

5

6

7

8

L

N

CONNECT AS IN FIGURE

ON

CONNECT

THE POWER

After about 30s

MOTOR MAKES A MOVEMENT

OPPOSITE TO ANOTHER

= RESET DONE

IF POSSIBLE BRING THE MOTOR

IN AN INTERMEDIATE POSITION

S

OFF

120-230V

50-60Hz

M

MAX 7A

230V

1

2

3

4

5

6

7

8

X60

e

GO

G

G

S

S

L

N

ON

Movements

of the motor

Insertion

delay

1 movement

00 s

2 movements

10 s

3 movements

20 s

4 movements

30 s

5 movements

40 s

6 movements

50 s

DISCONNECT

THE POWER

RESTORE THE CONNECTIONS

(see scheme at section 2 )

CONNECT

THE POWER

All products and technical specifications given in this document are subject to variation without notice. The manufacturer shall not be liable for damage resulting from improper, incorrect or
unreasonable use. Hereby MASTER SpA declares that this device complies with the essential requirements and other relevant provisions of Directives. The declaration of conformity can be
requested at the following email address: [email protected]