4. PROGRAMMING MENU
Through the programming menu you can set some functions of the module.
4.1. Working time
The module provides the ability to program the working time (time needed to bring the motor from the lower end position to the upper end position). The factory sets the working time
of 130 sec. The working time can vary from a minimum of 1 sec to a maximum of 250 sec.
How to set the working time:
- Bring the motor in an intermediate position.
- Disconnect the power to the module and wait a few seconds. Connect the power to the module.
- Within 15 sec press briefly 5 times (less than 0.5 sec) in quick succession the
▼
S button. The motor makes 3 upward movements.
- Press briefly
S. The motor performs a downward manoeuvre. Wait until the motor stops for the intervention of the previously set mechanical limit switch.
▲
- Press briefly
S. The motor performs an upward manoeuvre. Wait until the motor stops for the intervention of the previously set mechanical limit switch.
▲
- Press briefly
S. The module saves the working time and indicates the operation with an alternate movement of the motor (downwards and upwards).
▲
4.2. Insertion delay on general command
The module is equipped with inputs for the general command. In the event that it is necessary to distribute the start of motors to avoid overloading the power line, you can use this function.
The general commands (upward or downward) will be performed from the module after the selected delay. The factory sets the "insertion delay on the general command" at value 1 (00
seconds = immediate start).
How to modify the insertion delay :
- Bring the motor in an intermediate position.
- Disconnect the power to the module and wait a few seconds. Connect the power to the module.
- Within 15 sec press briefly 5 times (less than 0.5 sec) in quick succession the
▼
S button. The motor makes 3 upward movements.
-
S. The motor returns to its initial position and performs 4 upward movements.
Press briefly
▼
-
S. The module performs a number of upward movements equal to the currently set value (see table).
Press briefly
▲
- If you want to modify the setting, press briefly S a number of times equal to the desired value (see table).
▲
- After approximately 8 seconds, the module displays the setting and return to normal activities.
4.3. «Air change» function
If the module is used for the movement of roller shutters, it can be useful to activate this function. Pressing briefly for 2 times (less than 0.5 sec) in quick succession button
▼
S, the module
lowers the roller shutter and, at the end of working time, it commands a small upward movement, such as to permit ventilation.
Pressing briefly for 2 times (less than 0.5 sec) in quick succession the
▼
G button the operation will affect all the roller shutters wired to the General button and will be followed in respect of
the insertion delay on the general command. The duration of short upward movement can be set according to the size of the roller shutter. The factory sets the function "air change" to the
value 1 (INACTIVE).
How to set the duration of the small upward movement:
- Bring the motor in an intermediate position.
- Disconnect the power to the module and wait a few seconds. Connect the power to the module.
- Within 15 sec press briefly 5 times (less than 0.5 sec) in quick succession the
▼
S button. The motor makes 3 upward movements.
-
S. The motor returns to its initial position and performs 4 upward movements.
Press briefly
▼
-
S. The motor returns to its initial position and performs 5 upward movements.
Press briefly
▼
-
S. The module performs a number of upward movements equal to the currently set value (see table).
Press briefly
▲
- If you want to modify the setting, press briefly S a number of times equal to the desired value (see table).
▲
- After approximately 8 seconds, the module displays the setting and return to normal activities.
Movements
of the motor
«Air change»
function
1 movement
INACTIVE
2 movements
01 s
3 movements
02 s
4 movements
03 s
5 movements
04 s
6 movements
05 s
4.4. Selection of the operating logic of the buttons
- Bring the motor in an intermediate position.
- Disconnect the power to the module and wait a few seconds. Connect the power to the module.
- Within 15 sec press briefly 5 times (less than 0.5 sec) in quick succession the
▼
S button. The motor makes 3 upward movements.
-
S. The motor returns to its initial position and performs 4 upward movements.
Press briefly
▼
-
S. The motor returns to its initial position and performs 5 upward movements.
Press briefly
▼
-
S. The motor returns to its initial position and performs 6 upward movements.
Press briefly
▼
-
S. The module changes the setting and indicates the operation with an alternate movement of the motor (downwards and upwards).
Press briefly
▲
5. RESET
- Disconnect the power to the module.
- Connect together the terminals 1, 5, 6 as in figure.
- Connect the power to the module. After about 30 s the motor performs two brief movements (alternate) to show the restoration of factory conditions.
- Disconnect the power to the module.
- Restore the connections and connect the power.
OFF
DISCONNECT
THE POWER
1
2
3
4
5
6
7
8
L
N
CONNECT AS IN FIGURE
ON
CONNECT
THE POWER
After about 30s
MOTOR MAKES A MOVEMENT
OPPOSITE TO ANOTHER
= RESET DONE
IF POSSIBLE BRING THE MOTOR
IN AN INTERMEDIATE POSITION
S
OFF
120-230V
50-60Hz
M
MAX 7A
230V
1
2
3
4
5
6
7
8
X60
e
GO
G
G
S
S
L
N
ON
Movements
of the motor
Insertion
delay
1 movement
00 s
2 movements
10 s
3 movements
20 s
4 movements
30 s
5 movements
40 s
6 movements
50 s
DISCONNECT
THE POWER
RESTORE THE CONNECTIONS
(see scheme at section 2 )
CONNECT
THE POWER
All products and technical specifications given in this document are subject to variation without notice. The manufacturer shall not be liable for damage resulting from improper, incorrect or
unreasonable use. Hereby MASTER SpA declares that this device complies with the essential requirements and other relevant provisions of Directives. The declaration of conformity can be
requested at the following email address: [email protected]