Troubleshooting
Problem:
Water conditioner fails to regenerate. No soft water.
Possible Cause
Solution
Power supply to MP-Clear
Reflections control has been
interrupted.
Determine reason for power
interruption and correct. Reset time of
day.
Water pressure lost.
Restore water pressure.
Corrupted programming of MP-
Clear Reflections timer.
Reprogram timer assembly.
Defective MP-Clear Reflections
timer.
Replace timer assembly.
No salt in brine tank.
Add salt and regenerate.
Manual bypass valve is open.
Close manual bypass valve.
Leak at riser pipe seal.
Insure that riser pipe is properly
sealed at o’ring seal. Inspect pipe for
cracks.
Insufficient brine.
Check brine float height and clean
assembly if necessary. Check flow
rate capabilities of safety float and air
check assembly.
Plugged injector or injector screen. Inspect and clean injector and/or
injector screen.
Problem:
No Brine Draw
Possible Cause
Solution
Plugged injector or injector screen. Inspect and clean injector and/or
injector screen.
Insufficient water pressure.
Increase water pressure above 25
psig (172kPa) minimum.
Corrupted programming of MP-
Clear Reflections timer.
Reprogram timer assembly.
Defective MP-Clear Reflections
timer.
Replace timer assembly.
Obstructed drain line.
Remove obstruction.
Summary of Contents for MP-CLR-30
Page 1: ...MP CLR UF Top Mount Water Softeners June 2015 Version Installation and Operation Manual...
Page 13: ...11...
Page 19: ...17 ERROR CODES...
Page 20: ...18...
Page 21: ...19 CLEAR REFLECTIONS PARTS...
Page 22: ...20 CLEAR REFLECTIONS PARTS...
Page 23: ...21 CLEAR REFLECTIONS PARTS...
Page 24: ...22 CLEAR REFLECTIONS PARTS...
Page 25: ...23...
Page 33: ...ERROR CODES...
Page 34: ......