background image

NEVER LEAVE HEATER UNATTENDED WHILE BURNING, 

CONNECTED TO A POWER SOURCE, OR WHILE 

CONNECTED TO A FUEL SOURCE

© 2014, Pinnacle Products International, Inc. 

Convection Heater User's Manual

 

ALWAYS install the heater so that it is not directly 

exposed to water spray, rain, dripping water, or 

wind.

 

Use heater in accordance with all local codes.  

In the absence of local codes, refer to The 

National Fuel Code, ANSI Z223.1.

 

This heater is shipped from the factory 

for use with propane (LP) gas only.

 Do not 

convert to any other gas. Installation must 

conform to local codes, or in their absence, 

with the standard for the Storage and 

Handling of Liquefied Petroleum Gases ANSI/

NFPA 58 and the Natural Gas and Propane 

Installation Code CSA B149.1.

 

Gas supply connections should be checked 

by using a 50/50 soap and water solution. 

Never use a flame to check for gas leaks.

 

Locate LP cylinder at least 6 feet (10 ft. in 

Canada) from the heater, and do not direct 

heater discharge towards the LP cylinder 

unless it is at least 20 feet from the heater.

 

Use only the regulator and hose assembly 

provided with this heater. Inspect the 

regulator/hose assembly prior to each use of 

the heater. If there is excessive abrasion or 

wear, or if the hose is cut, replace it with the 

proper assembly shown in the parts list, prior 

to using the heater.

Minimum and Maximum Inlet Pressure

80V-LPC-A

200V-LPC-A

Min.

5 PSI

Max.

Bottle Pressure

Safety Information

The hose assembly shall be 

pro tected from traffic, building 

material and contact with hot surfaces both 

during use and while in storage

.

WARNING

1. 

Remove all packing items applied to heater for 

shipment. Keep plastic cover caps attached to 

inlet connector and hose / regulator assembly 

for storage.

2. 

Remove all items from carton

3. 

Check all items for shipping damage. If the 

heater is damaged, promptly inform dealer 

where you purchased the heater. 

The Propane (LP) gas 

pressure regulator and hose 

assembly supplied with the heater must be 

used without alteration. 

CAUTION

Unpacking

X

RISK OF FIRE! ALWAYS LOCATE HEATER ON A STABLE AND LEVEL SURFACE!

WARNING

 Figure 1

For use with propane (LP) 

 

gas only.

WARNING

3

Summary of Contents for MH-200V-LPC-A

Page 1: ...ONING AND OR ELECTRIC SHOCK ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL LA...

Page 2: ...signed and approved for use as a construction heater in accordance with Standard ANSI Z83 7 2011 CSA 2 14 2011 CHECK WITH YOUR LOCAL FIRE SAFETY AUTHORITY IF YOU HAVE ANY QUESTIONS ABOUT APPLICATIONS...

Page 3: ...INDOOR USE PERMITTED ONLY FOR The temporary heating of adequately ventilated buildings or structures under construction alteration or repair Provide at least a three square foot 2 800 sq cm opening of...

Page 4: ...ds the LP cylinder unless it is at least 20 feet from the heater Use only the regulator and hose assembly provided with this heater Inspect the regulator hose assembly prior to each use of the heater...

Page 5: ...ure 2 Specifications Model MH 80V LPC A MH 200V LPC A BTU 60 000 70 000 80 000 70 000 200 000 Fuel Consumption Lbs hr 2 8 3 2 3 7 3 2 9 3 Heat Settings 3 Variable Maximum Operating Hours 36 31 Require...

Page 6: ...hipping Retain caps for covering the inlet connector and regulator hose fro storage 3 Inspect heater closely for any damage that may have occurred during shipping If there is any damage return the hea...

Page 7: ...National Standard for Compressed Gas Cylinder Valve Outlets and Inlets Connections A safety relief valve having direct communications with the vapor space of the LP cylinder The heater must operate o...

Page 8: ...urn ON the LP cylinder valve and check for leaks with soap solution Checking For Leaks To check for leaks make up a 50 50 solution of dish soap and water Apply this solution to all gas connections If...

Page 9: ...ise to close it MH 200V LPC A 1 STOP Read all of the safety information provided with this heater 2 Turn valve on propane cylinder COUNTERCLOCKWISE until fully open 3 Set control valve to LIGHT LOW po...

Page 10: ...R Storage Maintenance Always disconnect the heater from the LP cylinder before putting the heater into storage If for any reason the heater is to be stored indoors the tank MUST be disconnected from t...

Page 11: ...h time for thermocouple to warm up 2 Gas pressure too low 3 Thermocouple needs replacing or loose 4 Control valve damaged 1 Keep Control Valve depressed for at least 30 seconds 2 Check cylinders for a...

Page 12: ...SOURCE OR WHILE CONNECTED TO A FUEL SOURCE 2014 Pinnacle Products International Inc Convection Heater User s Manual 1 1 2 2 3 3 4 4 5 6 7 8 9 9 10 10 11 11 12 12 13 14 13 14 15 16 17 17 18 19 20 18 1...

Page 13: ...rol Valve Ball Valve 24 015 0003 7 Piezo Lighter 24 122 0003 8 Valve Assembly 24 011 0020 9 Wind Screen 24 526 0001 24 526 0001 10 Base 24 501 0010 24 501 0011 11 Thermocouple 24 091 0002 24 091 0003...

Page 14: ...turned freight collect This Limited Warranty is in lieu of all other express warranties Pinnacle Products International Inc disclaims al warranties for products that are purchased from sellers other t...

Page 15: ..._____ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ___________...

Page 16: ...2014 Pinnacle Products International Inc 668 Stony Hill Road 302 Yardley PA 19067 USA Toll Free 800 641 6996 Fax 215 891 8461 Web www pinnacleint com Email info pinnacleint com...

Reviews: