NEVER LEAVE HEATER UNATTENDED WHILE BURNING, 

CONNECTED TO A POWER SOURCE, OR WHILE 

CONNECTED TO A FUEL SOURCE

© 2014, Pinnacle Products International, Inc. 

Convection Heater User's Manual

Safety Information

The products described in this manual are 

propane direct-fired, forced air heaters. Propane 

forced air heaters are primarily intended for 

use for temporary heating of buildings under 

construction, alteration or repair. Direct-fired 

means that all of the combustion products of the 

heater enter the heated space. This appliance 

is rated at 98% combustion efficiency, but does 

produce small amounts of carbon monoxide.

Carbon monoxide is toxic. Humans can tolerate 

only small amounts of carbon monoxide and so 

precautions should be taken to provide proper 

ventilation. Failure to provide proper ventilation 

in accordance with the instructions in this manual 

can result in death.
People with breathing problems should consult a 

physician before using this heater. 
Early signs of carbon monoxide poisoning 

resemble the flu. Symptoms of improper 

ventilation / carbon monoxide poisoning are:

Headache 

• Dizziness •

 Nausea 

• 

Dry Mouth 

Sore Throat 

 Burning of Nose and Eyes

If you experience any of these symptoms:

 

GET FRESH AIR AT ONCE! 

Have your heater 

serviced and check for proper ventilation. Some 

people are more affected by carbon monoxide 

than others. These include: pregnant women, 

those with heart or lung problems, anemia or those 

under the influence of alcohol or at high altitudes. 

FOR OUTDOOR USE. INDOOR USE 

PERMITTED ONLY FOR: The temporary 

heating of adequately ventilated buildings or 

structures under construction, alteration or 

repair! Provide at least a three square foot 

 

(2,800 sq cm) opening of outside air for 

every 100,000 Btu / Hr heater rating. Refer to 

“Ventilation” on page 8 for further instructions. 

WHAT TO DO IF THE SMELL OF GAS IS PRESENT:

 

DO NOT attempt to light the heater.

 

Extinguish any open flame.

 

Shut off gas to heater.

 

If odor continues, contact your local gas 

supplier or fire department.

 

DO NOT touch or use any electric switch or 

any electric device that can cause a spark.

 

Immediately call your gas supplier from a 

neighbors phone. Follow the gas suppliers 

instructions.

 

If you can not reach your gas supplier, call 

the fire department. 

 

Service must be done by a qualified 

service agency.

NEVER store or use gasoline or other flammable 

vapors and liquids in the vicinity of this heater.
NEVER store

 

a propane (LP) cylinder not 

connected to this heater in the vicinity of this heater.

NEVER 

connect heater to an unregulated gas supply.

NEVER 

obstruct the flow of combustion and 

ventilation air. 
NEVER use duct work in front or rear of heater.
NEVER modify this heater or operate a heater that 

has been modified.
NEVER service, move or handle heater while still 

hot or operating
Keep all combustible materials away from this heater.

Minimum Clearance From Combustibles

Sides

Top

48 in.

96 in.

RISK OF INDOOR AIR 

POLLUTION!

WARNING

CARBON MONOXIDE POISONING 

MAY LEAD TO DEATH!

DANGER

RISK OF BURNS, FIRE AND 

EXPLOSION!

WARNING

PROPANE IS AN 

 

EXPLOSIVE GAS.

DANGER

CAUTION! HOT WHILE IN 

OPERATION. DO NOT TOUCH. 

KEEP CHILDREN, ANIMALS, CLOTHING AND 

COMBUSTIBLES AWAY FROM HEATER. 

WARNING

2

Summary of Contents for MH-200V-LPC-A

Page 1: ...ONING AND OR ELECTRIC SHOCK ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL LA...

Page 2: ...signed and approved for use as a construction heater in accordance with Standard ANSI Z83 7 2011 CSA 2 14 2011 CHECK WITH YOUR LOCAL FIRE SAFETY AUTHORITY IF YOU HAVE ANY QUESTIONS ABOUT APPLICATIONS...

Page 3: ...INDOOR USE PERMITTED ONLY FOR The temporary heating of adequately ventilated buildings or structures under construction alteration or repair Provide at least a three square foot 2 800 sq cm opening of...

Page 4: ...ds the LP cylinder unless it is at least 20 feet from the heater Use only the regulator and hose assembly provided with this heater Inspect the regulator hose assembly prior to each use of the heater...

Page 5: ...ure 2 Specifications Model MH 80V LPC A MH 200V LPC A BTU 60 000 70 000 80 000 70 000 200 000 Fuel Consumption Lbs hr 2 8 3 2 3 7 3 2 9 3 Heat Settings 3 Variable Maximum Operating Hours 36 31 Require...

Page 6: ...hipping Retain caps for covering the inlet connector and regulator hose fro storage 3 Inspect heater closely for any damage that may have occurred during shipping If there is any damage return the hea...

Page 7: ...National Standard for Compressed Gas Cylinder Valve Outlets and Inlets Connections A safety relief valve having direct communications with the vapor space of the LP cylinder The heater must operate o...

Page 8: ...urn ON the LP cylinder valve and check for leaks with soap solution Checking For Leaks To check for leaks make up a 50 50 solution of dish soap and water Apply this solution to all gas connections If...

Page 9: ...ise to close it MH 200V LPC A 1 STOP Read all of the safety information provided with this heater 2 Turn valve on propane cylinder COUNTERCLOCKWISE until fully open 3 Set control valve to LIGHT LOW po...

Page 10: ...R Storage Maintenance Always disconnect the heater from the LP cylinder before putting the heater into storage If for any reason the heater is to be stored indoors the tank MUST be disconnected from t...

Page 11: ...h time for thermocouple to warm up 2 Gas pressure too low 3 Thermocouple needs replacing or loose 4 Control valve damaged 1 Keep Control Valve depressed for at least 30 seconds 2 Check cylinders for a...

Page 12: ...SOURCE OR WHILE CONNECTED TO A FUEL SOURCE 2014 Pinnacle Products International Inc Convection Heater User s Manual 1 1 2 2 3 3 4 4 5 6 7 8 9 9 10 10 11 11 12 12 13 14 13 14 15 16 17 17 18 19 20 18 1...

Page 13: ...rol Valve Ball Valve 24 015 0003 7 Piezo Lighter 24 122 0003 8 Valve Assembly 24 011 0020 9 Wind Screen 24 526 0001 24 526 0001 10 Base 24 501 0010 24 501 0011 11 Thermocouple 24 091 0002 24 091 0003...

Page 14: ...turned freight collect This Limited Warranty is in lieu of all other express warranties Pinnacle Products International Inc disclaims al warranties for products that are purchased from sellers other t...

Page 15: ..._____ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ___________...

Page 16: ...2014 Pinnacle Products International Inc 668 Stony Hill Road 302 Yardley PA 19067 USA Toll Free 800 641 6996 Fax 215 891 8461 Web www pinnacleint com Email info pinnacleint com...

Reviews: