1.  When facing the front of the Logix timer, the inlet connection 

(

Figure 1)

 is located on the left and the outlet connection is on the 

right.   The control valve's inlet and outlet connections are either 
1” copper or PVC equipped with gasket and nut.

 

Figure 1

 

 

 Install the 263 bypass valve 

(See Figure 2) 

with inlet and outlet 

handles facing upward.  Place gasket into nut and secure 1” copper 

or PVC tail piece with a nut.  Repeat the procedure for the outlet 

connection.   

DO NOT OVERTIGHTEN THE NUT.

  

 

Figure 2

 

 

 

2.  The control valve's drain connection is 3/4" npt and is located on 

the back of the control valve.   

3.  Turn the control valve upside down and ensure that  the control 

valve distributor o'rings are in place.  Use silicone lubricant on 
the o'rings. 

4.    Place the control valve onto the distributor pipe.  

 
 
 
 

5.    Thread the control valve hand tight to 20 foot pounds! 

Summary of Contents for MBA-MM-1010

Page 1: ...Installation and Operation Manual MBA MM 1040 10 13 1665 MULTI MEDIA FILTERS with the 263 742 Logix Control Valve MASTER Water Conditioning Corp www masterwater com June 2010 ...

Page 2: ... Piping Layout 8 Electrical Supply Electrical Requirements Logix 263 742 Control Valve Electrical Connection Instructions on Logix 742 Electrical Connection 9 Filling Multi Media filter with Water Details for Filling Multi media filter Tank with Water 10 Logix 263 742 Control Valve Timer Instructions on Logix 742 Timer Settings 11 Logix 263 742 Control Valve Timer cont d Instructions on Logix 742 ...

Page 3: ...Multi Media Filter _______ MBA MM 10 1 1 5 CF Multi Media Filter _______ MBA MM 13 1 2 5 CF Multi Media Filter _______ MBA MM 1665 1 4 0 CF Multi Media Filter NOTE Product Change The brine plug 1030334 was added and the brine line connection has an orange cap plug 191 Orange Cap See Figure below DO NOT REMOVE CAPS OR PLUGS ...

Page 4: ... of non corrosive Noryl material and is rated at a maximum working water pressure of 100 psi It uses a 742 microprocessor based timer to actuate regeneration in the following ways a Manual regeneration button to start an emergency regeneration b Regeneration day setting NOTE THIS FILTER IS NOT INTENDED TO BE USED FOR TREATING WATER THAT IS MICROBIOLOGICALLY UNSAFE OR OF UNKNOWN QUALITY WITHOUT ADE...

Page 5: ... Sand Philterkol MBA MM 1040 n a 12 lbs 8 lbs 25 lbs 17 lbs 13 lbs MBA MM 10 n a 20 lbs 12 lbs 37 lbs 25 lbs 19 lbs MBA MM 13 n a 25 lbs 16 lbs 50 lbs 35 lbs 25 lbs MBA MM 1665 n a 50 lbs 50 lbs 100 lbs 80 lbs 50 lbs 4 Pour all filter media provided with the unit into the top of the tank See page one for your specific model number of unit to determine the amount of media to load into the mineral t...

Page 6: ...ndles facing upward Place gasket into nut and secure 1 copper or PVC tail piece with a nut Repeat the procedure for the outlet connection DO NOT OVERTIGHTEN THE NUT Figure 2 2 The control valve s drain connection is 3 4 npt and is located on the back of the control valve 3 Turn the control valve upside down and ensure that the control valve distributor o rings are in place Use silicone lubricant o...

Page 7: ...g codes when installing our water treatment equipment 2 If sweat fittings are used be sure soldering is done in such a manner as not to allow heat to reach the control valve or bypass If Schedule 80 PVC is used make sure to follow the proper primer and solvent instructions 3 The drain line connection is located on the back of the valve as you face the timer It is recommended you install a union on...

Page 8: ...e drain piping size to below Maximum drain line length is 30 feet Maximum drain line height is 6 feet above the control valve The drain line must be piped to an open air gap See Figure 3 Always follow local plumbing codes ...

Page 9: ...E All Master Water Conditioners must be installed after the well tank or water meter if its public water supply Master Water Conditioner Air Gap Drain Treated water Untreated to outside 224 Shoemaker Rd Pottstown PA 19464 Typical Piping Layout ...

Page 10: ...rs per day We recommend installing a surge protector to protect unit from power surges which are not covered by warranty Logix Control Valve Electrical Connection Note Do not touch the wiring harness between the Logix timer and the motor it s positioning is critical and therefore already installed at the factory 1 Remove plastic control valve cover by spreading sides while lifting 2 Plug transform...

Page 11: ... rate Warning IF WATER ENTERS THE TANK TOO FAST ALL THE MEDIA WILL BE FLUSHED TO DRAIN DURING START UP 2 When water is running steadily at the drain open the bypass valve s inlet and outlet to their maximum position 3 Simultaneously press the SET and UP buttons on the controller for 1 second then release the motor will advance the cam to C2 4 Once C2 is displayed simultaneously press the SET and U...

Page 12: ... 2 To change the Time of Day use the UP or DOWN arrows 3 Press the SET button Day of Week Setting 1 Press the SET button The screen will show the Day of Week in blinking triangle 2 To change the Day of Week use the UP or DOWN arrows 3 Press the SET button Time of Regeneration Setting the factory default is 1 AM 1 Press the SET button The screen will show the Time of Regeneration in blinking number...

Page 13: ...Check 1 Inspect the treated water to assure that the media fines color have been flushed from the unit Make sure the drain line connection meets all plumbing codes and that the drain line size can handle the backwash flow rate of the multi media filter 2 Make sure the Inlet and Outlet on bypass valve are open 3 Make sure the control valve timer is plugged into an electrical outlet with power 24 ho...

Page 14: ... for cracks Symptom Loss of Media to Drain Possible Cause Solution No flow control installed in drain line Install drain line flow control Symptom Leak to Drain Possible Cause Solution No flow control installed in drain line Install drain line flow control Insufficient water pressure Increase water pressure above 25 psig 172kPa minimum Damaged valve disk or obstruction in valve disk Inspect and if...

Page 15: ...13 ...

Page 16: ...14 ...

Page 17: ...15 ...

Page 18: ...16 ...

Page 19: ...ll be void in the event of damages from external sources or where the conditioner has been operated at pressure in excess of 100 pounds per square inch or at a temperature greater than 100 degrees F or less than 32 degrees F Incidental costs or consequential damages are not covered by this warranty All defective parts shall be returned prepaid to Master Water Conditioning Corporation for inspectio...

Reviews: