2.
Remove and clean
3.
Turn valve to ON
4.
Replace thermocouple
5. Place pilot properly
6. Position properly and retry
A. CONSTRUCTION AND CHARACTERISTICS
► Transportable terrace/garden heater with tank housing
► Casing in steel with powder-coating or stainless steel
► Gas hose connections with metal clamp (screw caps
for Germany)
► Heat emission from reflector
B. SPECIFICATIONS
► Use propane or butane gas only
► Max. wattage: 13000 watts
► Min. wattage: 5000 watts
► Consumption:
GAS CATEGORY:
I
3+(28-30/37)
I
3B/P(30)
I
3B/P(50)
I
3B/P(37)
TYPES OF GAS:
Butane
Propane
LPG Gas Mixtures
LPG Gas Mixtures
LPG Gas Mixtures
GAS PRESSURE:
28-30 mbar
37 mbar
30 mbar
50 mbar
37 mbar
CONSUMPTION:
450-870 g/h
640-1230 g/h
550-1060 g/h
► With CE certificates
C. TABLE OF INJECTOR
GAS CATEGORY:
I
3+(28-30/37)
I
3B/P(30)
I
3B/P(50)
I
3B/P(37)
TYPES OF GAS:
Butane
Propane
LPG Gas Mixtures
LPG Gas Mixtures
LPG Gas Mixtures
GAS PRESSURE:
28-30 mbar
37 mbar
30 mbar
50 mbar
37 mbar
TOTAL HEAT
INPUT (Hs): (Qn)
13 kW (870 g/h)
INJECTOR SIZE:
1.90 mm for main burner
0.18 mm for pilot burner
1.70 mm for main burner
0.18 mm for pilot burner
1.80 mm for main burner
0.18 mm for pilot burner
► The hose and regulator assembly must conform to local
standard codes.
► Regulator outlet pressure should meet the correspon-
ding gas category in the table of injector.
► The appliance requires approved hose in 1.4m length.
BG
BY
CZ
EE
HR
HU
LT
LV
RO
GB
SI
SK
UA
SE
SI