8
101964
OPERATION
To Start Heater
1. Follow all ventilation and safety information.
2. Fill fuel tank with kerosene or No. 1 fuel oil.
3. Attach fuel cap.
4. Set thermostat dial to desired temperature.
Note:
Thermostat setting must be
higher than surrounding air temperature.
5. Plug power cord of heater into a standard 220/240 volt, 50 hertz, grounded
(earthed) outlet. Use an extension cord if needed. Use only a three-wire,
grounded (earthed) extension cord.
Extension Cord Wire Size Requirements
Up to 100 feet (30.5 meters) long, use 16 AWG (1.0 mm
2
) conductor
101 to 200 feet (30.6 to 61 meters) long, use 14 AWG (1.5 mm
2
) conductor
201 to 300 feet (61.1 to 91.5 meters) long, use 12 AWG (2 mm
2
) conductor
6. The motor will start when power cord is plugged into outlet. The heater should
ignite at once. If heater does not ignite, restart heater. To restart heater, wait
60 seconds, then push in flame-out control reset button. Flame-out control
reset button is at rear of heater near power cord (see Figure 4).
Note:
If starting heater for first time, you may need to restart heater several times
before heater ignites. You may also have to do this after taking heater out of
storage.
WARNING
Review and understand the warnings in the Safety Information
Section. They are needed to safely operate this heater.
;;;
;;;
;;;
Flame-out
Control Reset
Button
Figure 4 - Flame-out Control Reset Button