OUTDOOR UNIT INSTALLATION

For left piping and left rear piping, preset the end of the pipe to the
dimensions shown in Fig. 21 from the mark on the wall hook bracket
and form the connection pipe.

Bend the connection piping at a bend radius of at least 4“ (100
mm) and position it no more than 2“ (50 mm) from the wall.

Fig. 21

Connection pipe
 1/2” (12.7 mm dia.)

About 17-5/16

” (440 mm)

About

14-31/32” (380 mm)

Connection pipe
 1/4” (6.35 mm dia.)

Bend (R100) with
a pipe bender

When extending the drain hose at the indoor unit, install the

accessory drain insulation.

Fig. 22

Place the indoor unit drain hose behind the piping.

[Installing the indoor unit]

Piping work can be made easier by laying out, shaping, and tem-
porarily fastening the connection pipe, drain hose, and connec-
tion cord as shown in Fig. 23 beforehand.

Fig. 23   (Left piping)

Drain insulation

Drain hose

Vinyl tape

Indoor unit drain hose

Indoor unit

Connection cord

Pipe

Connect the piping

Drain hose

INSTALLING THE INDOOR UNIT

After connecting the piping, fasten the bottom of the indoor unit and
the wall hook bracket with the tapping screws.

Fig.24

Indoor unit

Wall hook bracket

Pipe bracket

Tapping screw

 WARNING

1

Install the unit where it will not be tilted by more
than 5°.

2

When installing the outdoor unit where it may
exposed to strong wind, fasten it securely.

Set the unit on a strong stand, such as one made of concrete
blocks to minimize shock and vibration.

Do not set the unit directly on the ground because it will cause
trouble.

OUTDOOR UNIT PROCESSING

When the outdoor unit will be exposed to strong wind, fasten it
with bolts at the places indicated by the arrows (Fig. 25).

Fig. 25

Bottom

25-19/32” (650 mm)

4-ø12 hole (Anchor bolt M10)

15-3/4” (400 mm)

Summary of Contents for 9369651014

Page 1: ...erheating at connection points and a possible fire hazard When Transporting Be careful when picking up and moving the indoor and outdoor units Get a partner to help and bend your knees when lifting to...

Page 2: ...0 F 35 C DB 110 F 43 3 C DB humidity about 80 or less Cooling Minimum 65 F 18 C DB 32 F 0 C DB STANDARD ACCESSORIES The following installation accessories are supplied Use them as required INDOOR UNIT...

Page 3: ...at the wall hook bracket Wall hook bracket Tapping screw big Handle of screwdriver Tap Hook String Wall hook bracket Hook Counter weight Center notch 1 Cut a 3 2 16 80 mm diameter hole in the wall at...

Page 4: ...ain hose through the wall hole hang the indoor unit on the hooks at the top and bottom of the wall hook bracket Fig 8 Connection pipe 1 4 6 35 mm dia Align the marks Connection pipe 3 8 9 52 mm dia or...

Page 5: ...fere with the air flow 2 Install the outdoor unit in a place where it will be free from be ing dirty or getting wet by rain as much as possible 3 Install the unit when connection to the indoor unit is...

Page 6: ...ere it is intended to be installed If the place is not strong enough a plank or girder should be used to make the place sufficiently strong so that the wall can support the weight Installation directl...

Page 7: ...o 10 mm less 3 8 10 mm or over 3 15 16 100 mm dia hole 1 Rear piping 2 Right piping 3 Bottom piping Install the indoor unit piping in the direction of the wall hole and bind the drain hose and pipe to...

Page 8: ...onnec tion cord as shown in Fig 23 beforehand Fig 23 Left piping Drain insulation Drain hose Vinyl tape Indoor unit drain hose Indoor unit Connection cord Pipe Connect the piping Drain hose INSTALLING...

Page 9: ...INDOOR UNIT OUTDOOR UNIT Check if L is flared uniformly and is not cracked or scratched L dimension Thin pipe 6 35 mm dia 1 4 to 1 7 mm Thick pipe 12 7mm dia 1 9 to 2 2 mm 4 CONNECTION 1 Install the...

Page 10: ...trip 3 8 10 mm Strandwire Screw with special washer Screw with special washer Round terminal Round terminal terminal board Round terminal Wire Wire WARNING 1 Before starting work check that power is n...

Page 11: ...Cabinet D Knockout hole Edge cover Pipe mounting hole Power supply line Inter Unit line 3 Connect the piping and power supply cord from the mounting holes 4 Temporarily mount the conduit tubes on the...

Page 12: ...ocess the end of the connection cords to the dimension shown in Fig 40 and bend the end of each wire as shown 5 Connect the end of the connection cord fully into the terminal board and fasten with the...

Page 13: ...ve core OUTDOOR UNIT Cap OUTDOOR UNIT 3 way valve 2 way valve Service hose Gauge manifold Vacuum pump Connection pipe WARNING 1 The rated voltage of this product is 230 208 V A C 60 Hz 2 Before turnin...

Page 14: ...ler so that rain water and wind cannot blow in 6 Fasten the drain hose to the outside wall etc UNIT B Installing the under covers 1 Installing under cover A Fig 42 1 Hook the two pipe bracket hooks to...

Page 15: ...ovement continue lifting upward to remove 2 Pull past the intermediate catch and open the intake grille wide so that it becomes horizontal Fig 50 2 UNLOCK THE INTAKE GRILLE Hold the intake grille with...

Page 16: ...here any gas leakage Do not operate the air conditioner in the test run mode for a long time For the operation method refer to the operating manual and per form operation check Error display Error con...

Reviews: