Master 9369651014 Installation Instruction Sheet Download Page 5

SELECTING THE MOUNTING POSITION

1.

INDOOR UNIT

(1) Install the indoor unit level on a strong wall which is not subject

to vibration.

(2) The inlet and outlet ports should not be obstructed : the air should

be able to blow all over the room.

(3) Do not install the unit where it will be exposed to direct sun-

light.

(4) Install the unit where connection to the outdoor unit is easy.
(5) Install the unit where the drain pipe can be easily installed.
(6) Take servicing, etc. into consideration and leave the spaces

shown in (Fig. 1). Also install the unit where the filter can be
removed.

Fig. 1

Left side
5 cm
or over

6 cm or over

Right side
5 cm
or over

150 to 200 cm

150 cm
or over

Fig. 3

UNIT B (Large)

UNIT A2 (Small)

UNIT A1 (Small)

2.

OUTDOOR UNIT

(1) If possible, do not install the unit where it will exposed to direct

sunlight. (If necessary, install a blind that does not interfere with
the air flow.)

(2) Install the outdoor unit in a place where it will be free from be-

ing dirty or getting wet by rain as much as possible.

(3) Install the unit when connection to the indoor unit is easy.
(4) Do not place animals and plants in the path of the warm air.
(5) Take the air conditioner weight into account and select a place

where noise and vibration are small.

(6) Select a place so that the warm air and noise from the air condi-

tioner do not disturb neighbors.

(7) Provide the space shown in Fig. 2 so that the air flow is not

blocked. Also for efficient operation, leave open three of the four
directions front, rear, and both sides.

(8) Install the unit near the special branch circuit.

Fig. 2

 CAUTION

MINIMUM CIRCUIT AMPACITY

25A

MAXIMUM OVERCURRENT PROTECTION

30A

(TIME DELAY FUSE OR HACR TYPE CIRCUIT BREAKER)

30 cm

or over

60 cm

or over

60 cm or over

10 cm
or over

1 cm or over

ELECTRICAL REQUIREMENT

Always make the air conditioner power supply a special branch cir-
cuit and provide a special switch and receptacle. Do not extend the
power cord.

Summary of Contents for 9369651014

Page 1: ...erheating at connection points and a possible fire hazard When Transporting Be careful when picking up and moving the indoor and outdoor units Get a partner to help and bend your knees when lifting to...

Page 2: ...0 F 35 C DB 110 F 43 3 C DB humidity about 80 or less Cooling Minimum 65 F 18 C DB 32 F 0 C DB STANDARD ACCESSORIES The following installation accessories are supplied Use them as required INDOOR UNIT...

Page 3: ...at the wall hook bracket Wall hook bracket Tapping screw big Handle of screwdriver Tap Hook String Wall hook bracket Hook Counter weight Center notch 1 Cut a 3 2 16 80 mm diameter hole in the wall at...

Page 4: ...ain hose through the wall hole hang the indoor unit on the hooks at the top and bottom of the wall hook bracket Fig 8 Connection pipe 1 4 6 35 mm dia Align the marks Connection pipe 3 8 9 52 mm dia or...

Page 5: ...fere with the air flow 2 Install the outdoor unit in a place where it will be free from be ing dirty or getting wet by rain as much as possible 3 Install the unit when connection to the indoor unit is...

Page 6: ...ere it is intended to be installed If the place is not strong enough a plank or girder should be used to make the place sufficiently strong so that the wall can support the weight Installation directl...

Page 7: ...o 10 mm less 3 8 10 mm or over 3 15 16 100 mm dia hole 1 Rear piping 2 Right piping 3 Bottom piping Install the indoor unit piping in the direction of the wall hole and bind the drain hose and pipe to...

Page 8: ...onnec tion cord as shown in Fig 23 beforehand Fig 23 Left piping Drain insulation Drain hose Vinyl tape Indoor unit drain hose Indoor unit Connection cord Pipe Connect the piping Drain hose INSTALLING...

Page 9: ...INDOOR UNIT OUTDOOR UNIT Check if L is flared uniformly and is not cracked or scratched L dimension Thin pipe 6 35 mm dia 1 4 to 1 7 mm Thick pipe 12 7mm dia 1 9 to 2 2 mm 4 CONNECTION 1 Install the...

Page 10: ...trip 3 8 10 mm Strandwire Screw with special washer Screw with special washer Round terminal Round terminal terminal board Round terminal Wire Wire WARNING 1 Before starting work check that power is n...

Page 11: ...Cabinet D Knockout hole Edge cover Pipe mounting hole Power supply line Inter Unit line 3 Connect the piping and power supply cord from the mounting holes 4 Temporarily mount the conduit tubes on the...

Page 12: ...ocess the end of the connection cords to the dimension shown in Fig 40 and bend the end of each wire as shown 5 Connect the end of the connection cord fully into the terminal board and fasten with the...

Page 13: ...ve core OUTDOOR UNIT Cap OUTDOOR UNIT 3 way valve 2 way valve Service hose Gauge manifold Vacuum pump Connection pipe WARNING 1 The rated voltage of this product is 230 208 V A C 60 Hz 2 Before turnin...

Page 14: ...ler so that rain water and wind cannot blow in 6 Fasten the drain hose to the outside wall etc UNIT B Installing the under covers 1 Installing under cover A Fig 42 1 Hook the two pipe bracket hooks to...

Page 15: ...ovement continue lifting upward to remove 2 Pull past the intermediate catch and open the intake grille wide so that it becomes horizontal Fig 50 2 UNLOCK THE INTAKE GRILLE Hold the intake grille with...

Page 16: ...here any gas leakage Do not operate the air conditioner in the test run mode for a long time For the operation method refer to the operating manual and per form operation check Error display Error con...

Reviews: