SELECTING THE MOUNTING POSITION
1.
INDOOR UNIT
(1) Install the indoor unit level on a strong wall which is not subject
to vibration.
(2) The inlet and outlet ports should not be obstructed : the air should
be able to blow all over the room.
(3) Do not install the unit where it will be exposed to direct sun-
light.
(4) Install the unit where connection to the outdoor unit is easy.
(5) Install the unit where the drain pipe can be easily installed.
(6) Take servicing, etc. into consideration and leave the spaces
shown in (Fig. 1). Also install the unit where the filter can be
removed.
Fig. 1
Left side
5 cm
or over
6 cm or over
Right side
5 cm
or over
150 to 200 cm
150 cm
or over
Fig. 3
UNIT B (Large)
UNIT A2 (Small)
UNIT A1 (Small)
2.
OUTDOOR UNIT
(1) If possible, do not install the unit where it will exposed to direct
sunlight. (If necessary, install a blind that does not interfere with
the air flow.)
(2) Install the outdoor unit in a place where it will be free from be-
ing dirty or getting wet by rain as much as possible.
(3) Install the unit when connection to the indoor unit is easy.
(4) Do not place animals and plants in the path of the warm air.
(5) Take the air conditioner weight into account and select a place
where noise and vibration are small.
(6) Select a place so that the warm air and noise from the air condi-
tioner do not disturb neighbors.
(7) Provide the space shown in Fig. 2 so that the air flow is not
blocked. Also for efficient operation, leave open three of the four
directions front, rear, and both sides.
(8) Install the unit near the special branch circuit.
Fig. 2
CAUTION
MINIMUM CIRCUIT AMPACITY
25A
MAXIMUM OVERCURRENT PROTECTION
30A
(TIME DELAY FUSE OR HACR TYPE CIRCUIT BREAKER)
30 cm
or over
60 cm
or over
60 cm or over
10 cm
or over
1 cm or over
ELECTRICAL REQUIREMENT
Always make the air conditioner power supply a special branch cir-
cuit and provide a special switch and receptacle. Do not extend the
power cord.